TMYTEK PLO-SG CLI Script User Guide

Label Detail
RF A RF signal output channel A
RF B RF signal output channel B
10 MHz Out Internal 10MHz reference clock output
10/100 MHz In External reference clock input
Type-C USB connection for power and control
Lock Lock status indicator

Requirements

  1. Python
    • Version >= 3.8
  2. pyserial packege
    • Use command pip install pyserial to install package
  3. CP2102 driver for windows user

Help

Use --help or -h to show help message.

python .\plo_sg_api.py --help
usage: plo_sg_api.py [-h] [-v] [-s] [-c COM] [-f [FREQ]] [-n NTH] [-t] [--id] [--hw_ver] [--fw_ver] [--post_multi] [--sn] [--plo_sn] [--dip_sw] [-p [OUT_PWR]] [-o [OUT_CFG]] [-k [REF_CLK]] [-r [REF_CFG]] [-l]

optional arguments:
  -h, --help            show this help message and exit
  -v, --version         plo_sg_api version
  -s, --scan            Scan SG device and list info
  -c COM, --com COM     Com port. If not specified will connect to first SG in scan list
  -f [FREQ], --freq [FREQ]
                        Set/Get output frequency (kHz). Use --nth to access saved frequency
  -n NTH, --nth NTH     Nth saved frequency. Use with --freq
  -t, --freq_cnt        Get how many set of frequency that can be saved
  --id                  Get internal PLO module id
  --hw_ver              Get internal PLO module hw version
  --fw_ver              Get internal PLO module fw version
  --post_multi          Get internal PLO output post multiplication. 0: X1, 1: X2, 2: X4
  --sn                  Get SG sn
  --plo_sn              Get internal PLO module internal sn
  --dip_sw              Get dip switch reading
  -p [OUT_PWR], --out_pwr [OUT_PWR]
                        Set/Get output power step (0 ~ 12)
  -o [OUT_CFG], --out_cfg [OUT_CFG]
                        Set/Get output config. 0: Disable OUT A&B, 1: Enable OUT A Only, 2: Enable OUT B Only, 3: Enable OUT A&B
  -k [REF_CLK], --ref_clk [REF_CLK]
                        Set/Get reference clock frequency (kHz)
  -r [REF_CFG], --ref_cfg [REF_CFG]
                        Set/Get reference clock config. 0: Internal ref clock, 1: Output ref clock, 2: External ref clock input
  -l, --get_lock        Get lock status

Usage

Scan PLO-SG device

Use --scan or -s to scan and list PLO-SG device.

Example

python .\plo_sg_api.py --scan

Connect to PLO-SG device

Use --com or -c to connect to PLO-SG on specific com port. If no com port is provided the cli will connect to the first device in the scan list.

Example

  • Connect to PLO-SG on com8.
python .\plo_sg_api.py --com COM8

Output frequency

Use --freq or -f to set/get output frequency in kHz. The PLO-SG device supports output frequency from 180MHz to 18GHz.

Additionally use --nth or -n to save or read frequency to/from predefined frequency set inside internal memory. The number of available frequency set can be obtained using --freq_cnt.

Example

  • Set first device in scan list to output 6GHz (6000000kHz) w/o saving to memory.
python .\plo_sg_api.py --freq 6000000
  • Set PLO-SG on com8 to output 6GHz (6000000kHz) w/o saving to memory.
python .\plo_sg_api.py --com COM8 --freq 6000000
  • Set PLO-SG on com8 to output 6GHz and save to frequency set 0 in internal memory.
python .\plo_sg_api.py --com COM8 --freq 6000000 --nth 0
  • Get PLO-SG current output frequency on com8.
python .\plo_sg_api.py --com COM8 --freq
  • Get PLO-SG frequency set 0 value from internal memory on com8.
python .\plo_sg_api.py --com COM8 --freq --nth 0

Output power

Use --out_pwr or -p to set/get output power step. The PLO-SG device supports 13 steps of output power control. Higher setting value provides more output power.

Setting Value Detail
0 OFF
1 Minimum Power
... ...
12 Maximum Power

Example

  • Set output power of PLO-SG on com8 to step 6.
python .\plo_sg_api.py --com COM8 --out_pwr 6
  • Get output power from PLO-SG on com8.
python .\plo_sg_api.py --com COM8 --out_pwr

Output channel config

Use --out_cfg or -o to set/get output enable config. The PLO-SG device supports independent enable/disable control for both channel.

Setting Value Detail
0 Disable both channel
1 Only Enable Channel A
2 Only Enable Channel B
3 Enable both channel

Example

  • Set channel config of PLO-SG on com8 to enable both channel.
python .\plo_sg_api.py --com COM8 --out_cfg 3
  • Get channel config from PLO-SG on com8.
python .\plo_sg_api.py --com COM8 --out_cfg

Reference clock frequency

Use --ref_clk or -k to set/get reference clock frequency in kHz. The PLO-SG device supports using different reference clock frequency.

Example

  • Set reference clock of PLO-SG on com8 to use 10MHz (10000kHz).
python .\plo_sg_api.py --com COM8 --ref_clk 10000
  • Get reference clock from PLO-SG on com8.
python .\plo_sg_api.py --com COM8 --ref_clk

Reference in/out config

Use --ref_cfg or -r to set/get reference clock in/out config. The PLO-SG device supports output internal reference clock or use external reference clock.

Setting Value Detail
0 Use internal reference clock, disable output
1 Use internal reference clock, enable output
2 Use external reference clock

Example

  • Set reference config of PLO-SG on com8 to output reference clock.
python .\plo_sg_api.py --com COM8 --ref_cfg 1
  • Get reference config from PLO-SG on com8.
python .\plo_sg_api.py --com COM8 --ref_cfg

PLO-SG serial number

Use --sn to get PLO-SG device serial number.

Example

  • Get sn from PLO-SG on com8.
python .\plo_sg_api.py --com COM8 --sn

Lock status

Use --get_lock or -l to get PLO-SG pll lock status.

Value Detail
0 Unlock
1 Locked

Example

  • Get lock status from PLO-SG on com8.
python .\plo_sg_api.py --com COM8 --get_lock