Skip to content
#

hardware-timers

Here are 24 public repositories matching this topic...

This library enables you to use Interrupt from Hardware Timers on an AVR ATmega164, ATmega324, ATmega644, ATmega1284 with MCUdude MightyCore. It now supports 16 ISR-based timers, while consuming only 1 Hardware Timer. Timers interval is very long (ulong millisecs). The most important feature is they are ISR-based timers. Therefore, their executi…

  • Updated Dec 5, 2022
  • C

This library enables you to use Interrupt from Hardware Timers on Arduino AVRDx-based boards (AVR128Dx, AVR64Dx, AVR32Dx, etc.) using DxCore. These AVRDx Hardware Timers, using Interrupt, still work even if other functions are blocking. Moreover, they are much more precise (certainly depending on clock frequency accuracy) than other software tim…

  • Updated Dec 5, 2022
  • C

This library enables you to use Interrupt from Hardware Timers on an RTL8720-based board. These RTL8720 Hardware Timers, using Interrupt, still work even if other functions are blocking. Moreover, they are much more precise (certainly depending on clock frequency accuracy) than other software timers using millis() or micros(). That's mandatory i…

  • Updated Dec 5, 2022
  • C

This library enables you to use Interrupt from Hardware Timers on an ESP32-S2-based board. These ESP32-S2 Hardware Timers, using Interrupt, still work even if other functions are blocking. Moreover, they are much more precise (certainly depending on clock frequency accuracy) than other software timers using millis() or micros(). That's mandatory…

  • Updated Dec 21, 2022
  • C++

This library enables you to use Interrupt from Hardware Timers on an SAM-DUE-based board. These SAM-DUE Hardware Timers, using Interrupt, still work even if other functions are blocking. Moreover, they are much more precise (certainly depending on clock frequency accuracy) than other software timers using millis() or micros(). That's mandatory i…

  • Updated Dec 5, 2022
  • C++

This library enables you to use Interrupt from Hardware Timers on Arduino AVR ATtiny-based boards (ATtiny3217, etc.) using megaTinyCore. These ATtiny Hardware Timers, using Interrupt, still work even if other functions are blocking. Moreover, they are much more precise (certainly depending on clock frequency accuracy) than other software timers …

  • Updated Dec 5, 2022
  • C

This library enables you to use Interrupt from Hardware Timers on an ATmega4809-based board, such as Arduino UNO WiFi Rev2, AVR_NANO_EVERY, etc. It now supports 16 ISR-based timers, while consuming only 1 hardware Timer. Timers' interval is very long (ulong millisecs). The most important feature is they're ISR-based timers. Therefore, their exec…

  • Updated Dec 5, 2022
  • C

This library enables you to use Interrupt from Hardware Timers on an ESP32-C3-based board. These ESP32-C3 Hardware Timers, using Interrupt, still work even if other functions are blocking. Moreover, they are much more precise (certainly depending on clock frequency accuracy) than other software timers using millis() or micros(). That's mandatory…

  • Updated Dec 21, 2022
  • C++

This library enables you to use Interrupt from Hardware Timers on an ESP32, ESP32_S2, ESP32_S3 or ESP32_C3-based board. It now supports 16 ISR-based timers, while consuming only 1 Hardware Timer. Timers' interval is very long (ulong millisecs). The most important feature is they're ISR-based timers. Therefore, their executions are not blocked by…

  • Updated Dec 21, 2022
  • C++

This library enables you to use Interrupt from Hardware Timers on RP2040-based boards such as Nano_RP2040_Connect, RASPBERRY_PI_PICO. These MBED_RPI_PICO_TimerInterrupt Hardware Timers, using Interrupt, still work even if other functions are blocking. Moreover, they are much more precise (certainly depending on clock frequency accuracy) than oth…

  • Updated Dec 5, 2022
  • C

This library enables you to use Interrupt from Hardware Timers on an Teensy-based board such as Teensy 4.x, 3.x, LC, 2.0, etc. These Teensy Hardware Timers, using Interrupt, still work even if other functions are blocking. Moreover, they are much more precise (certainly depending on clock frequency accuracy) than other software timers using mill…

  • Updated Dec 5, 2022
  • C++

This library enables you to use Interrupt from Hardware Timers on an NRF52-based board using mbed-RTOS such as Nano-33-BLE. These nRF52 Hardware Timers, using Interrupt, still work even if other functions are blocking. Moreover, they are much more precise (certainly depending on clock frequency accuracy) than other software timers using millis()…

  • Updated Dec 5, 2022
  • C++

This library enables you to use Interrupt from Hardware Timers on an nRF52-based board. These nRF52 Hardware Timers, using Interrupt, still work even if other functions are blocking. Moreover, they are much more precise than other software timers using millis() or micros(). Now supports `Sparkfun Pro nRF52840 Mini`

  • Updated Dec 5, 2022
  • C++

This library enables you to use 1 Hardware Timer on ESP32-based board to control 16 or more servo motors. Now supporting ESP32, ESP32_S2, ESP32_S3, ESP32_C3-based boards. Tested OK with ESP32 core v2.0.5

  • Updated Dec 5, 2022
  • C++

This library enables you to use Interrupt from Hardware Timers on RP2040-based boards such as RASPBERRY_PI_PICO. These RPI_PICO_TimerInterrupt Hardware Timers, using Interrupt, still work even if other functions are blocking. Moreover, they are much more precise (certainly depending on clock frequency accuracy) than other software timers using m…

  • Updated Dec 5, 2022
  • C++

This library enables you to use Interrupt from Hardware Timers on an STM32F/L/H/G/WB/MP1-based board. These STM32F/L/H/G/WB/MP1 Hardware Timers, using Interrupt, still work even if other functions are blocking. Moreover, they are much more precise (certainly depending on clock frequency accuracy) than other software timers using millis() or micr…

  • Updated Dec 5, 2022
  • C++

This library enables you to use Interrupt from Hardware Timers on an SAMD-based board. These SAMD Hardware Timers, using Interrupt, still work even if other functions are blocking. Moreover, they are much more precise (certainly depending on clock frequency accuracy) than other software timers using millis() or micros(). That's mandatory if you …

  • Updated Dec 5, 2022
  • C++

Improve this page

Add a description, image, and links to the hardware-timers topic page so that developers can more easily learn about it.

Curate this topic

Add this topic to your repo

To associate your repository with the hardware-timers topic, visit your repo's landing page and select "manage topics."

Learn more