Support for TIM361-2134101 #52
Comments
Hi, sadly the the newer firmwares don't support ranging, see #36 and linked issues for a discussion. You would need to talk to SICK regarding downgrading, afaik we never looked into that. |
The only thing you could try is ask @SICK-NorthAmerica for a solution. He mentioned in #33 that people should write him an email, so until he complains I'll keep pointing people with this problem in his direction. :) |
Thanks a lot for your suggestions! I will let you know when I find a solution. |
Hi, |
Hello,
I tried to use the launch file sick_tim sick_tim551_2050001.launch to connect to my TIM361-2134101.
Then I get the error that only TiM3xx: firmware versions < V2.5 are supported.
I see two options but I would like to ask for help:
Are you going soon to provide support for firmware version V2.54?
Is it possible to downgrade the firmware version of the laser? I did not see the option in the SOPAS Engineering Tool V3
Thanks in advance for any help you can provide
The text was updated successfully, but these errors were encountered: