Project Description

This repo has python code for reverse engineering the RS-485 protocol on a Hayward 81504 full inverter heatpump aka HP (water). This HP has a display and documented wifi connector-plug, but there is no way to buy that wifi controller. The HP is so-called a full inverter, but in reality has only 2 operational steps, slow/eco and full power. The unit can be set to eco-mode, but it "forgets" that eco mode so in the middle of the night it goes full power (and noisy). From observations this happens when upon hitting the "set-temperature". The original intent was to connect the HP up to an arduino and mimick and replace the external display and hook the arduino up to mqtt for display/control of main parameters: On/off/eco, set temp, read ingoing/outgoing temperature of water. For that to work, we need to reverse engineer the rs-485 bus.

Reverse engineering the RS-485 bus

The traffic on the internal RS-485 is 9600,8N1 and not following modbus or other hayward/aqualogic protocols. The python code produces CSV files that can be configured to have header & payload in the csv.

Hardware setup

The python code runs on a linux/windows machine with a USB RS-485 transceiver. That transceiver is hooked up in series with the HP's internal RS485 bus using JST-SM connectors as used in the HP.

Assumptions

  • Bus: RS485, half duplex, 9600, 8N1
  • Packet: no size or address field found inside the packets
  • All Packets have a unique 8-byte header
  • All Packets have 2 bytes of modbus crc-16 in little endian at the end of the packet
  • Packet sizes 8, 31, 65 185, 189 are the observed sizes
  • Master starts tx with packet, slave responds with packet
  • Timeout – 100-150 ms (unverified)
  • If slave response within timeout, new master tx

Observations

  • After heater start, ventilator starts after approx 11 sec
  • After heater start, without waterflow, E03 after approx 60 sec
  • M7 does not get response = gets retried 3 times, followed by a M8/S2
  • M10 does not get response = gets retried 3 times, followed by a M11/S2 sequence
  • Heater on results after approx 8 secs in M3 when S2 is expected, followed by S3 and 3 unanswered M7’s
  • Set temp change results after approx 12 secs in M4 when S2 is expected, followed by S4 and 3 unanswered M10’s
  • Heater on/off instant results in M6/S6 and M5/S5
  • M1 only gets answered 5 secs after power up
  • M1 stops responding 2 secs after power down
  • Unit stays bus active 17 secs after powered down

Message Table

So far, I identified 11 unique master headers, and 7 unique slave response headers, the actual 8-byte headers are in phyton_serial.py

Master ID Slave ID To Return Device MA SL
MA1 SL1 (SL1B) 8 65 Display 01030bb9001e1603 01033c5746323030
MA2 SL2 8 189 EEV 02030bb9001e1630 001007d1005ab457
MA3 SL3 189 8 Display 011003e9005ab457 011003e9005a9182
MA4 SL4 189 8 Display 01100443005ab457 01100443005ab0d6
MA5 SL5 31 8 Display 01100bb9000b1657 01100bb9000b520f
MA6 SL6 8 185 Display 010303e9005a1441 0103b45746323030
MA7 189 Unknown 021003e9005ab457
MA8 SL2 189 189 EEV 001003e9005ab457 001007d1005ab457
MA9 SL6 8 185 Display 01030443005a3515 0103b45746323030
MA10 189 Unknown 02100443005ab457
MA11 SL2 189 189 EEV 00100443005ab457 001007d1005ab457

Test sequence 00 (wo wif box)

The result of this test sequence can be found in tst00_01.csv and tst00_02.csv in the repo

  • 00:00 - START python logging
  • 00:00 - HP POWER supply switched on
  • 00:40 - HP POWER supply switched off
  • 00:55 - STOP python logging

Test sequence 01 (wo wif_box)

The result of this test sequence can be found in tst01_01.csv in the repo

  • 00:00 - START python logging
  • 00:10 - HP POWER supply switched on
  • 00:40 - Heater ON by pushing power button for 1 sec
  • 01:10 - Increase set temperature by 0.3 deg C - 4 pushes up
  • 01:30 - Heater OFF by pushing power buttor for 1 sec
  • 01:50 - HP POWER supply switched off
  • 02:10 - STOP python logging

Test sequence 02 (wo wif box)

The result of this test sequence can be found in tst02_01.csv in the repo

  • 00:00 - START python logging
  • 00:10 - HP POWER supply switched on
  • 00:40 - Heater ON by pushing power button for 1 sec
  • 01:35 - Heater OFF by pushing power buttor for 1 sec
  • 01:50 - HP POWER supply switched off
  • 02:10 - STOP python logging

Test sequence 03 (w wifibox)

  • 00:00 - START python logging
  • 00:00 - HP POWER supply switched on
  • 00:35 - HP POWER supply switched off
  • 00:50 - STOP python logging

Test sequence 04 (w wifibox)

  • 00:00 - START python logging
  • 00:00 - HP POWER supply switched on
  • 00:35 - Heater ON in app
  • 00:55 - Heater OFF in app
  • 01:15 - HP POWER supply switched off
  • 01:30 - STOP python logging

Packet Analysis

SL1

Byte 15 : 0x80 once upon startup
Byte 16 : 0x01 once upon heater on and upon heater off/ 0x40 once upon temp change
Byte 24 : Hour field
Byte 26 : Minutes field
Byte 28 : Seconds field

MA3

Byte 20 :
Byte 24 :
Byte 26 :

MA4

Byte : 90

Test Sequence 1 Analysis

HP POWER supply switched on

start MA1/MA2/SL2 - 3x times - approx 5 secs later
MA1/SL1 - first SL1 response with Byte 18 0x80
MA3/SL3
MA4/SL4
MA5/SL5
MA1/SL1/MA2/SL2 until Heater On or PSU off

HP PSU switched off

MA1/MA2/SL2 (No SL1 response) until psu dies after approx. 17 secs

Heater ON

MA1/SL1 Byte 16 0X01
MA6/SL6
MA5/SL5
MA1/SL1/MA2/SL2 loops

Approx 5 seconds later
MA3/SL3
MA7/MA7/MA7
MA8/SL2
MA1/SL1/MA2/SL2 loops

Approx 25 seconds later
MA4/SL4
MA10/MA10/MA10
MA11/SL2
MA1/SL1/MA2/SL2 loops

Heater OFF

MA1/SL1 Byte 16 0X01
MA6/SL6
MA5/SL5
MA1/SL1/MA2/SL2 loops

Approx 5 seconds later
MA3/SL3
MA7/MA7/MA7
MA8/SL2
MA1/SL1/MA2/SL2 loops

Set temperature change

Approx 5 seconds later
MA1/SL1 Byte 16 0X40 once
MA9/SL6
MA5/SL5
MA1/SL1/MA2/SL2 loops