New Features:
MS/MS processing
Local Database search
Processing Changes:
- Switch between Profile Data and Centroid Data, Profile Data will be centroided prior to ROI search.
- ROI search now uses intensity weighted average to determine ROI mass
- m/z correction with internal standard uses now Shape-preserving piecewise cubic Hermite (pchip) interpolation to generate correction values, instead of flat nearest neighbor correction. m/z correction values outside the mass range covered by internal standards are generated using nearest neighbor extrapolation.
- Internal standard normalization uses now Shape-preserving piecewise cubic Hermite (pchip) interpolation to generate correction values, instead of flat nearest neighbor correction.
- Support for measurements with polarity switching or positive and negative polarity measurements in a group.
- MS data are automatically converted from pseudo molecular ion mass to molecular mass depending on scan polarity.
- Isotopes are now filtered immediately after the files are loaded, before the ROI search.
What's Changed
- 1.2 development into stable by @AdrianHaun in #22
Full Changelog: v1.1.0...v1.2.0