Repository navigation
We're proud to introduce ThermoNova, the biggest release of the Smart Autotune Thermostat so far. Almost every part of the integration was rebuilt: the PID controller, PWM, the way SAT talks to your boiler, and how it handles rooms. On top of that, SAT now learns from your home over days and seasons and tells you what it finds.
New Features
- Rooms-only mode: No main room? Leave the inside temperature sensor empty and let the rooms drive the boiler. Each room gets its own PID and heating curve, and the boiler only runs while a room asks for heat.
- Room presets: Give each room its own preset temperatures. Presets only ever lower a room relative to its own home temperature, so a cool bedroom is not heated up by Comfort.
- Domestic hot water: A water heater entity to set the hot water setpoint and turn it on or off.
- Frost protection: Keeps heating when a room gets too cold, even while the thermostat is off.
- OTThing support: A new MQTT gateway, including auto discovery.
- Boiler health: Pressure monitoring, a fault sensor, and repair issues for boiler faults, slow pressure loss, frequent top-ups and worsening short cycling.
- Heating curve advice: A recommended coefficient learned from a week of steady heating, a seasonal fit over up to 180 days, and how much extra heat your house needs in wind.
- Insights: Heating efficiency per degree day from your gas meter, and a room balance sensor per room that shows which rooms are short of heat.
- Adaptive preheat: SAT learns how fast each room warms up and offers a
sat.estimate_preheatservice, plus three blueprints: Adaptive Preheat, Presence Presets and Holiday Mode. - Solar gain compensation: Lowers the heating output while the sun warms your home.
- Energy dashboard: A cumulative gas consumption sensor, and long-term statistics for the numeric sensors.
- Diagnostics: Config entry diagnostics for easier issue reports, state-based icons, and diagnostic and configuration entities in their own categories.
- Greek translation, and complete translations for all other languages.
Improvements
- No more calibration: Overshoot protection no longer needs the 20 minute calibration and is on for everyone. SAT learns what your boiler does while it runs.
- New PID controller: Works much better with coarse or slow temperature sensors, and keeps its state across restarts.
- New PWM: Follows the actual flame, respects the cycles per hour over a true rolling hour, and resumes where it was after a restart.
- PID ON/OFF: On/off heaters are cycled with Pulse Width Modulation, based on the Temperature Setting from the setup.
- Cycle tracking: Every burner cycle is measured and classified, so SAT can recognise short cycling, overshoot and underheating and react to it.
- ESPHome: SAT now talks to the device directly through the native API, and keeps working across reloads and disconnects.
- EMS-ESP: Whole-degree flow setpoints, no more toggling of heating activation, respect for the boiler's minimum power, and better hot water detection.
- OpenTherm Gateway: Setpoints are sent with one decimal over MQTT, boiler faults are read over MQTT, and the serial connection is more robust.
- Thermostats: The target temperature is pushed to the configured thermostat entity, and climate entities can be used as temperature sensors.
- Rooms: Rooms that are off no longer count, and the heater is turned off when all valves are closed.
- Faster control: The heating loop now runs every 5 seconds.
Bug Fixes
- Saving the options no longer fails with "Config entry has already been setup!" or leaves a second instance running.
- A valve used as the on/off heater is now actually opened and closed.
- The
reset_integralandpulse_width_modulationservices work again, now as entity services. - The heater is commanded off when the climate is turned off.
- Hot water demand no longer starts a spurious PWM cycle or triggers the sync sensors.
- Window sensors can no longer leave the activity preset engaged by an orphaned timer.
- MQTT topics and listeners are cleaned up when an entry is removed or reloaded.
- Migration no longer fails when the referenced device was removed from the registry.
- The gas consumption sensor reports a volume flow rate.
Breaking Changes
- Removed options: Sample time, automatic duty cycle, derivative time weight, and the dynamic minimum setpoint with its adjustment factor are gone. SAT now handles these itself.
- Calibration removed: The calibration step is no longer part of the setup.
- Overshoot protection for everyone: If you skipped calibration in an earlier version, SAT will now switch to Pulse Width Modulation on its own when your boiler overshoots.
- PID ON/OFF: On/off heaters are now cycled with Pulse Width Modulation. Before, they stayed on for as long as there was demand. Check that the Temperature Setting matches your heater.
- Device and entity names: The SAT device is now named after your thermostat instead of "Smart Autotune Thermostat". On Home Assistant 2026.10 and newer, entity names start with that name, for example "Living Room Hot Water".
- ESPHome: SAT finds the entities by their
object_id. Check your yaml against the example in the README. - Room temperatures: On the first start, SAT moves the room temperatures it had remembered into the new Room Presets tab. Please check them after updating.
- Gas consumption sensor: Its device class changed, so Home Assistant may ask you to fix its statistics.
Your configuration and entities are migrated automatically. Because so much changed, please make a backup before updating.
And as always, thank you for your feedback and support!