Repository navigation
CAL Audio Analyzer v1.10.0
Professional real-time sound system and room acoustics analyzer: RTA and spectrum, dual-channel transfer function with coherence and phase, spectrogram, impulse response, log-sweep room acoustics (RT60 / EDT / C50 / C80), EQ assistant, calibrated SPL meter, and remote access from phones and tablets.
Download
| System | File |
|---|---|
| Windows 10/11 – installer | CAL-Audio-Analyzer-<version>-win-x64.exe |
| Windows 10/11 – portable (no install) | CAL-Audio-Analyzer-<version>-portable.exe |
| macOS – Apple Silicon (M1–M4) | CAL-Audio-Analyzer-<version>-mac-arm64.dmg |
| macOS – Intel | CAL-Audio-Analyzer-<version>-mac-x64.dmg |
| Linux – x64 | CAL-Audio-Analyzer-<version>-linux-x86_64.AppImage |
| Linux – ARM64 (e.g. Raspberry Pi 5) | CAL-Audio-Analyzer-<version>-linux-arm64.AppImage |
The builds are not code-signed yet:
- Windows: if SmartScreen shows “Windows protected your PC”, click More info → Run anyway.
- macOS: open the .dmg and drag the app to Applications. The first time, right-click the app → Open → Open. If macOS says the app “is damaged”, run
xattr -dr com.apple.quarantine "/Applications/CAL Audio Analyzer.app"in Terminal. - Linux:
chmod +x CAL-Audio-Analyzer-*.AppImage, then run it.
On first launch, choose Explore with the demo room to try every feature without hardware.
What's new in 1.10
- Average curve your way: hide or show the average curve with the eye button next to Average (it keeps averaging while hidden, so the target stays levelled), and choose its colour and thickness under Options → Average curve.
- Battery saver: Tools → Display & performance → Battery saver. Auto (the default) turns it on while a laptop, tablet or phone runs on battery; On keeps it on. It draws about 15 times per second instead of 60, computes 10 new spectra per second instead of 25, draws graphs at standard resolution and sends remote devices 10 updates per second. Measurements stay exact: every audio sample is still analysed, and the SPL meter and noise log are not affected. The status bar shows when it is on.
- Target curves on Sweep & Room: pick a target (built-in or a stored trace) next to the result tabs. It is drawn with its tolerance band over the swept frequency response, levelled to the response, and has its own choice separate from the live views.
- Reset to defaults: Tools → Reset analysis & display to resets the analysis and display settings to the App defaults or to a Classic dual-FFT setup (1/12-octave transfer function, 16 averages, coherence, ±18 dB scale, high-resolution spectrum). Microphones, calibrations, inputs, remote access and saved workspaces stay as they are. Reset all settings still starts completely fresh.
- Fixes and tuning:
- The average curve took each new spectrum into account twice when analysing locally, so its time constant differed slightly from what remote devices showed.
- Changing the noise log interval no longer drops the unfinished row. At sample rates below 44.1 kHz the log's band columns stay aligned in the CSV (bands the sample rate can't measure are left blank).
- The remote-access server no longer stops when a device sends a message over its size limit. Song uploads over 60 MB are refused on the device with a message instead.
- Reconnecting a remote device, or restarting remote access, no longer leaves a stale connection behind.
- A sweep started from a remote device now reports an error if it can't be played, instead of waiting forever.
- A sweep interrupted by an audio restart now stops with a message instead of producing a wrong result.
- With ASIO, generator samples the driver couldn't take at once are played later instead of skipped, so sweeps stay intact.
- Averaging RTA traces from mics with different calibrations converts each to dB SPL first.
- Calibrating a mic with an empty reference level is refused instead of calibrating to 0 dB SPL.
- The EQ source now follows the measurement itself, not its position in the list.
- A session file with a damaged sweep is refused before anything is changed.
- Opening sessions with many traces is faster.
- The audio thread does less work per sample.
- A second launch of the desktop app only brings the running one to the front.
- Unused code has been removed.
What's new in 1.9.1
- SPL meter and noise log measured sample-exactly: the meter and log are now computed entirely from the audio samples, independent of the screen, its refresh rate and the analysis settings. Each log row covers exactly its interval (to the sample), Lmax is tracked on every sample, the 2-minute history is recorded every 100 ms of audio, and the log's third-octave bands come from their own IEC 61260-style band filters instead of the spectrum display. The numbers update at a steady 4 per second so they are easy to read. While a noise log runs, its weighting and input are locked, and switching workspace no longer changes them; every row records its weighting, which is also in the CSV.
- Remote devices show the target and average curves: the host's target curve, tolerance, average curve and multi-mic average settings now apply on connected phones and tablets, and the average curve is drawn from the host's analysis.
- Faster spectrum: the spectrum updates about 25 times per second (was about 6) with the same frequency resolution; Avg keeps the same averaging time. Remote devices receive 20 updates per second.
What's new in 1.9
- Several microphones, each calibrated: Tools → Microphones & calibration keeps a list of your measurement mics: the input each one is plugged into, its correction file and its own SPL calibration (calibrator or reference meter, through the meter's weighting). Every view uses the mic on its input: the spectrum shows each measurement in dB SPL with its own calibration, the SPL meter and noise log follow the mic on their input, and the input lists show the mic names. Settings from earlier versions become the first mic.
- System alignment: the Align tab now aligns the whole system to the mains: subs, front fills, out fills and delay speakers. Subs are aligned for summation through the crossover; fills and delay speakers for arrival across their overlap band (also 100+ ms for delay towers), with a precedence setting so the sound stays on stage. Each part can use the mains measured at its own handoff position. The result is an alignment plan (delay, polarity, level vs mains, summation) that goes into sessions and reports, with a warning when a speaker already arrives too late to fix with delay.
- A more polished look: bundled Inter and JetBrains Mono fonts (sharper, consistent on every system, also offline), refined graphite surfaces, consistent control sizes, focus rings, quieter scrollbars, clearer trace rows, fewer stacked messages, and no more emoji in the input list. Fixed: with many traces, the trace list ran under the assistant.
What's new in 1.8
- ASIO (Windows): choose ASIO: as the input source to use the interface's ASIO driver directly: every input and output channel, the driver's low latency, no system mixer or resampling. Set the sample rate, buffer size and safety margin, and open the driver's control panel, in Tools → Audio interface (ASIO). The generator signal that was actually played is recorded in the same driver callback as the inputs, so the internal reference stays sample-aligned with your microphones.
- Smoother average curve: the Spectrum's average line is now smoothed with a natural, bell-shaped window (1/6 octave by default; 1/12, 1/3, 1/1 or none under Options → Average curve), and it is drawn as a smooth curve over bars too.
- Several mics at once: Options → Several mics on the Spectrum and Transfer tabs shows the live power average of all measurement mics, with the spread between them as a band, or the average alone.
- Noise log (SPL tab): log Leq and Lmax every 1 s to 15 min with the third-octave spectrum, for hours. Set a level limit on the rolling Leq (e.g. 100 dB LAeq,15min); the level readout turns amber near it and red above it, with a warning. Export CSV; included in sessions and reports.
- Waterfall (Sweep & Room): cumulative spectral decay in 3-D, for room modes or the full range, also in the report.
- Trace notes and photos: attach a note and a photo of the mic position to any trace; shown in reports and kept in sessions.
- Cleaner screens: every tab now fits its controls in one row, even on a laptop. Everyday controls stay in the toolbar; less-used settings (FFT size, averaging, curve smoothing, target tolerance, several mics, panels, sweep options, EQ limits, alignment region) moved under Options. The SPL tab shows the 2-minute history or the noise log, one at a time; shorter tab names (EQ, SPL) and a compact workspace button make room in the tab bar.
- Workspaces: ready-made setups for live mixing, system tuning, sub alignment, voice systems, room surveys and noise monitoring, plus your own saved workspaces (with panel layouts), from the picker at the right of the tabs.
What's new in 1.7
- Target curves: choose a target (Flat, House, Tilt, X-curve or any stored trace) on the Spectrum or Transfer tab. It is drawn as a dashed line with a ±1–6 dB tolerance band and levels itself to the measurement, so you can see at a glance where the system is outside the target.
- Sub / main alignment assistant (new Align tab): capture the mains alone and the sub alone, press Calculate alignment, and get the delay (which side, in ms and metres/feet) and polarity that make them add up best through the crossover. It shows summation before and after, the gain at the crossover, warnings about remaining cancellations, the predicted sum and whether the phase tracks. The predicted sum can be stored as a trace.
- Sessions: Tools → Session & report saves everything for a job (traces, sweep, EQ, alignment, calibration, measurement setup, name, venue and notes) in one file, to continue later or on another computer.
- Reports: Create report builds a clean printable report (print, save as PDF or download as HTML) with the setup, spectrum and transfer function against the target (RMS deviation and share within tolerance), sweep response and RT60 table, EQ filters, alignment and notes.
- Tabs: Align is tab 7; the SPL meter and Tools move to 8 and 9.
What's new in 1.6.1
- Average curve moved to the Spectrum: the averaged curve for tuning is now a white line over the live RTA on the Spectrum tab (Average: 1 s, 3 s, 10 s, 30 s or everything since Restart; works with lines and bars). Hover to read it next to the live level. The spectrogram is back to its original layout (frequency up the side); frequency across remains an option under Layout.
What's new in 1.6
- Average curve on the spectrogram: a white averaged-spectrum line across the spectrogram shows the long-term tonal balance while you tune (Average: 1 s, 3 s, 10 s, 30 s or everything since Reset). Hover to read its level at any frequency.
- Spectrogram layout: frequency now runs across (newest data at the top, like a waterfall), so the average curve lies horizontally like a spectrum. The previous layout (frequency up the side) is one click away under Layout.
- Fix: RTA traces captured with a calibrated microphone now show at the right level in dB SPL (they appeared ~100 dB too low next to the live curve).
What's new in 1.5
- Faster everywhere: a new FFT (1.5–1.8× faster, and 2.7–3.2× for the spectrum's real-valued signals), results and graphs recomputed only when new data arrives, fewer screen updates for numbers that change every frame, and a lighter spectrogram. On the measurement computer the processing load dropped by roughly a third to more than half depending on the tab; on a slow phone the spectrum went from 36 to 54 frames per second.
- Security: the remote-access PIN protection now really locks out an address after 8 wrong PINs; the server refuses connections from other websites and unknown host names, and malformed addresses can no longer crash it.
- Fixes: remote devices no longer rebuild the generator controls several times a second while music plays (dropdowns and sliders now work there); Enter on a focused button no longer also starts/stops audio; shortcuts don't act behind open dialogs; a sweep requested from a remote device that the host can't run no longer leaves the remote waiting; long sweeps at very high sample rates are refused with a clear message instead of giving a wrong result; SPL Leq/Lmax reset when the calibration changes; several small leaks fixed (playlist window, database connections).
What's new in 1.4.2
- Spectrogram fixed with SPL calibration: with a calibrated microphone (or on a remote device using the host's calibration) the spectrogram showed a solid beige colour. The colour range now follows the calibration, the Floor/Top fields show dB SPL when calibrated, a new Auto button fits the range to the signal, and the range fits itself once when the signal is entirely outside it.
- The spectrogram's colour-scale legend shows the full colour scale again and fits on phone screens.
What's new in 1.4.1
- Smoother, more accurate low end: the longer bass windows now blend into the regular ones over a third of an octave instead of switching at a fixed frequency, so the spectrum and transfer function no longer show small steps at 45, 80, 90 or 160 Hz. The bass windows also update as often as the rest of the analysis, so the low end keeps up with changes (about 40% faster to settle than in 1.4.0).
- No more low bass right after connecting: after starting, reconnecting or joining as a remote device, the analysis no longer counts the silence from before the audio began, which could pull the low end down for a few seconds (or permanently with cumulative averaging).
What's new in 1.4
- Better low-end resolution: the spectrum and transfer function use longer analysis windows for the bass. Detail is 0.7 Hz (High, the new default) or 0.4 Hz (Maximum), instead of 2.9 Hz on the spectrum and 1.5 Hz on the transfer function. Tones 2 Hz apart at 40 Hz now show as two separate peaks. Mids and highs keep their fast response, and the extra processing is too small to measure because the bass windows run on a down-sampled copy of the signal. The bass needs a longer stretch of signal (≈1.4 s or 2.7 s) and reacts more slowly: choose Standard in Tools → Display & performance for the fastest bass response.
- The EQ filter export button is now called Copy filter text, and the calibration file help describes the supported file types.
What's new in 1.3
- Spectrum bars: show the RTA as 1/1, 1/3, 1/6, 1/12 or 1/24-octave bars (Display → Bars, or B). Peak hold shows as a cap on each bar.
- Much faster on older phones and tablets: remote devices now let the measurement host do the analysis and only draw the result. On-device analysis is also faster: the transfer function needs half the work, and a device only computes what is on screen. Auto graph quality lowers the resolution on devices that can't keep up. Settings are in Tools → Display & performance.
- Detached windows remember where they were: a panel detached again opens at its last position and size. The desktop app reopens detached windows when it starts. The new pin button keeps a detached window on top of other windows (desktop app; picture-in-picture in Chrome and Edge).
- Music generator with a playlist: play MP3, WAV, FLAC, OGG or M4A songs through the generator output. Add or drop files, reorder them, and use repeat or shuffle. Songs are level-matched to the generator level and act as the transfer-function reference. Remote devices can control the playlist and add songs from the phone.
What's new in 1.2
- One shared session across devices: the measurement host now keeps all results. A sweep started on a phone, tablet or the host runs on the host, shows its progress everywhere, and the result appears on every connected device (and on devices that connect later). Traces captured, renamed or deleted on any device appear on all of them. Calibration and channel setup changes on a remote reach the host and every other remote.
- Spectrum on remote devices fixed: the graph follows the host's SPL calibration instead of going off-scale (the screen-filling blue area).
- Zoom and move buttons on every graph (▲ ▼ − + Fit): always shown on touch screens, on hover with a mouse. Fit scales the graph to the data.
- Fullscreen button in the top bar (or F11).
What's new in 1.1
- Spectrum and Transfer tabs, each with its own movable, resizable and detachable panels (graphs, SPL meter, input level meters).
- Day mode: a high-contrast light colour scheme for use in direct sunlight (sun/moon button or T).
- Remote access: Tools → Remote access turns the app into a server. Phones, tablets and other computers on the same network scan the QR code or open the address shown, enter the PIN, and get every tab and meter live, including control of the generator and sweeps.