Skip to content

2026.10.06

Choose a tag to compare

@github-actions github-actions released this 06 Oct 21:31
· 117 commits to main since this release

⚠️ Upgrade notes (#805)

The ventilation schedule text entities text.<prefix>_timer_ventilation_schedule_week / _weekday / _weekend / _monday … _sunday (only present on units with a ventilation module, and never showing a valid state) are removed automatically. They are replaced by separate day and night schedules: text.<prefix>_timer_ventilation_day_schedule_<shape> and text.<prefix>_timer_ventilation_night_schedule_<shape>, matching the sun and moon pages of the controller's Lüftung → Zeitschaltprogramm menu. Automations or dashboard cards referencing the old entity ids have to be pointed at the new ones by hand.

⚠️ Upgrade notes (#808)

If your ventilation module has no exhaust-air sensor, sensor.<prefix>_ventilation_exhaust_air_temperature (which showed a constant 5 °C) is no longer created. The existing entity stays in the entity registry as "no longer provided by the integration" — delete it there. Units with a wired exhaust sensor are unaffected.

⚠️ Upgrade notes (#823)

On heat pumps without a solar thermal system, the solar entities are removed:

  • the binary sensor Solar Pump;
  • the sensors Solar Collector, Solar Buffer and Solar operating hours;
  • the four solar pump numbers.

Before this release they were created by mistake on many units and never showed meaningful values. If a dashboard card, automation or template still references one of them, remove that reference. On a heat pump without hot water, the then-empty hot water device is removed as well.

If you do have solar and these entities disappeared, please open an issue and attach a diagnostics download.

What's Changed

  • feat(sensor): ✨ add a last defrost timestamp sensor by @rhammen in #803
  • fix(text): 🐛 expose the ventilation schedule as day and night blocks by @rhammen in #805
  • chore(lux_overrides): 🔧 adopt upstream datatypes for the Mk3 timer block, limit temperatures and counters by @rhammen in #804
  • fix(sensor): 🐛 hide exhaust air temperature when the sensor is unwired by @rhammen in #808
  • feat(switch): ✨ add ZUP venting switch by @rhammen in #810
  • feat(switch): ✨ add manual EVU2 input for models that do not report SG2 by @rhammen in #812
  • fix(common): 🐛 keep decimals in luxtronik2.write values by @rhammen in #813
  • docs(advanced_features): 📝 describe both venting selection behaviours by @rhammen in #814
  • feat(sensor): ✨ expose compressor-2 heat meters on twin units by @rhammen in #816
  • refactor(coordinator): ♻️ declare entity_active gates on the descriptions by @rhammen in #817
  • feat(climate): ✨ set a room target for a plain rbe through the p0001 correction by @rhammen in #818
  • fix(manifest): 🐛 drop packaging from requirements by @rhammen in #822
  • feat(text): ✨ expose the circulation pump timer schedule and cycle times by @rhammen in #821
  • fix(coordinator): 🐛 stop detecting solar on pumps without it by @rhammen in #823
  • fix(const): 🐛 add heat pump type codes 89 and 90 by @rhammen in #824
  • fix(coordinator): 🐛 detect hot water on a freshly commissioned heat pump by @rhammen in #825

Full Changelog: 2026.09.16...2026.10.06