Skip to content

FiiO Devices

Bukutsu edited this page Oct 23, 2026 · 2 revisions

FiiO protocol notes

For the current model list and test statuses, use the searchable device catalog. It reflects the deployed web build. If the link opens the equalizer instead, the deployed build predates the catalog page.

These notes record the protocol review of FiiO Control Web, bundle index-7hb30NUo.js, on 2026-10-23. They explain identification and write constraints, rather than maintaining a second support inventory. External hardware reports do not make a Glacier profile Tested.

Identification and bank checks

A source-reviewed HID profile reads command 0x18 before an EQ mutation and again when reading the destination snapshot. A different count, missing response, or unsupported filter prevents an EQ write. Newer and beta firmware still needs physical-device captures to confirm its bank layout.

Known numeric routes use vendor 2972. Product-name routes are also registered under vendor 0A12, as in the reviewed reference catalog. They require the full USB product name, compared without case and surrounding whitespace. A missing PID is not a vendor-wide match. Unknown FiiO products and ordinary CSR devices are not enabled.

FIIO DSP Audio is the official alias for FIIO LS-TC2. Oak Nano also accepts FIIO OAK NANO; BTR17 accepts the reference catalog's BTR17 descriptor. QX11 is limited to HiFi PID 0130, not game PID 4014. BT11 and Air Link are limited to the official app's tengtai PIDs 4032 and 4033; other modes remain unsupported.

Tiny A expects ten bands, despite devicePEQ's five-band entry. Contour reports ten on a physical Tiny A, PID 0147, firmware 1.10. The mandatory count check rejects a different firmware layout.

What the new profiles do

  • Read EQ, normalize edits for the selected model, save to its User 1 bank, and verify the EQ readback. Reset writes a flat EQ through that same path.
  • Select and verify the write bank before taking the rollback snapshot. Writing User 1 must not back up User 2 and later restore it over User 1. Reading EQ alone does not select a preset.
  • Read the EQ-enable flag on QX13 and BTR15/19/25. If it is off, ask the user to enable EQ in FiiO Control first. Glacier does not enable it silently.
  • Send preset selection and SAVE once. A delivery error is not permission to replay either command. Short SAVE acknowledgements are drained before the immediate bank check.
  • Use model-specific command intervals. The K13 R2R gets 300 ms, and the BTR15/19/25 preset-switch paths get a conservative 1 s.
  • Keep temporary EQ, A/B, and live apply off on the new profiles until hardware confirms their volatile-write behavior.

Melody and Tiny A also offer playback presets, a selectable User 1–3 write destination, and stored User-slot names. The destination is a local choice until a write/reset selects it. Changing the playback preset changes the DAC immediately. Arbitrary preset queries can be stale, so the UI only confirms a preset after an explicit selection. See device workflows.

Filters and limits

Glacier represents peak, low shelf, high shelf, high-pass, and low-pass filters. FiiO wire IDs are 0, 1, 2, 5, 4 respectively. KA15, KA17, Melody, and the new models that allow pass filters expose those five types. BTR15, BTR17, FP3, FX25, LS-TC2, and Oak Nano retain the official app's three-type limit. Mage has peak, low shelf, high-pass, and low-pass, but no high shelf.

The official app also has band-pass and all-pass types, 3 and 6. Glacier cannot represent them. Reading a bank containing them fails rather than turning them into peak filters and overwriting the original bank. Use a bank with supported types in FiiO Control before writing.

Band gain stays inside Glacier's storage envelope, with a floor of −18 dB even when the official app allows −24 dB. Per-model preamp limits are separate. Melody retains its capture-backed whole-dB preamp. Tiny A's preamp resolution still needs confirmation in Glacier.

BTR17 uses the current official HID SAVE 0x19. devicePEQ's older BTR17 config uses 0x21; Glacier does not probe alternate SAVE opcodes. Test persistence after unplugging before relying on a saved profile.

Not supported

  • K15, K17, K17 R2R, K19: the official app uses a serial adapter. They are not HID variants, and some have 31-band banks. They need a serial transport and their own verified session behavior.
  • KA1, KA5, KA13 and unknown FiiO products: sharing vendor 2972 is not evidence of this PEQ protocol. The old KA-series fallback has been removed.
  • Other QX11/BT11/Air Link USB modes, USB20 aliases, and BLE-only paths.
  • Other models' volume, LED, Bluetooth, DAC-filter, balance, firmware update, and factory-reset controls. EQ protocol compatibility does not establish those commands.

Hardware checks needed

Start with a read and export a backup in FiiO Control. Use a spare User bank. Check a mild EQ, all bands, the selected write bank, another unchanged bank, reset-to-flat, and persistence after unplugging. On Tiny A, also check all three stored names and the preamp resolution.

Report the exact USB IDs, product name, firmware, platform, and diagnostic log. Do not mark a profile Tested from a synthetic test or another project's report.

Linux udev and Android attach filters still need vendor-level permission entries for product-name routes, because Android's filter cannot match a USB product string. Permission to enumerate a vendor is not permission for Glacier to drive every device under it; the application checks the model separately.

Sources

Reviewed 2026-10-23:

  • FiiO Control Web, bundle index-7hb30NUo.js: mne transport list, Ov report IDs, M8 filter types, $R presets, pv gain limits, Ff/q8e adapters, and KBe command pacing.
  • devicePEQ model configuration, constraints, HID handler, and KA15/KA17/JA11/QX13/Oak Nano captures at that revision. QX13 and Oak Nano capture bytes are exercised by codec tests; they are external captures, not Glacier hardware tests.
  • Contour FiiO catalog, protocol findings, and SnowSky name probes at that revision.
  • fiiocontrol-oss BTR17 identity, which records vendor 2972 and product ID 136 (0088).
  • The supplied Melody diagnostic capture, which established the exact device ID and whole-dB preamp mismatch.

The implementation follows published packet findings. It does not copy the official app or reference drivers into Glacier.