HSN framework is configured through the configuration file located at /etc/hsn2/framework.conf. An example of this file is provided below.
workflow.repository = /etc/hsn2/workflows/ AMQP.queues.framework.low= fw:l AMQP.queues.framework.high= fw:h AMQP.services= feeder-list, webclient, capture, swf-cve, shell-scdbg, js-sta, reporter, norm-url, rb-officecat, rb-pdffox AMQP.queues.objectStore.high= os:h AMQP.queues.objectStore.low= os:l AMQP.server.address= 127.0.0.1 # Exchange name for monitoring. Default value: notify # You can bind to it and consume monitoring messages while # job is in progress. #AMQP.exchange.monitoring= notify # Exchange name for common use. Default value: main #AMQP.exchange.common= main # Exchange name for service to bind to. Default value: direct #AMQP.exchange.services= direct jobs.sequence.file=/opt/hsn2/framework/jobId.seq # Uncomment it if you would like to limit number of maximum # simultaneously processing jobs. If parameter is not specified # or is less or equal to 0 there is unlimited maximum jobs. # # jobs.limit=10
You usually do not have to change any of these. However, these are the most commonly tweaked values:
- AMQP.services
-
List of all service names.
- AMQP.server.address
-
Address of the RabbitMQ installation.
Each service can be configured by adjusting its command line parameters. These can be done in /etc/init.d/hsn2-<service_name> file. You just have to modify the HSN_COMPONENT_PARAMS variable. Example of this variable declaration is provided below.
HSN2_COMPONENT_PARAMS="--connector 127.0.0.1 \ --dataStore http://127.0.0.1:8080 \ --maxThreads 30"
Parameters common for all services are:
- connector
-
Address of the RabbitMQ installation.
- dataStore
-
Address of the data store component (default port on which it listens is 8080).
- maxThreads
-
Number of threads on which the service will run. If it is a Python it is a number of processes. This is due to the CPython implementation solution called Global Interpreter Lock.
Framework accepts only one command line parameter:
- configPath
-
Path to the framework configuration file.
JavaScript Static Analyzer (js_sta) accepts three parameters which are correlated to the way it process contexts:
- trainingSet
-
Location of the Weka ARFF training set
- libPath
-
Location of libngrams, should not usually be changed, unless you know what you are doing
- whitelistPath
-
Path to the whitelist file.
In order to understand this parameters please read JavaScript static analyzer documentation.