Repository navigation
v2.4.2
The Remote Script is unchanged (2.1.0): no reinstall or Live restart needed.
The Claude Code plugin's new "Tool profile" option needs a new session.
Fixed
- A cue Live moved is deleted only where the playhead got to.
build_from_blueprintused to move the playhead to such a cue and toggle
without reading it back: where Live kept the playhead (past the song's
end) the toggle hit the cue there instead, and a locator placed right
could go. The playhead is now read back first; a cue it cannot reach is
left and reported (playhead,deleted: false). create_locatorandbuild_arrangementdelete a cue Live put at
another beat too, and say where it went; zooming the Arrangement in
reports its errors (zoom_errorsinbuild_from_blueprint's report).build_from_blueprintrefuses a set that holds a locator, which it
would otherwise rename where the blueprint asks for one.- A track named only with digits ("808") is that track, not track
808: as a tool'strack, a device's name, an input routing, and a
sidechain source (set_track_routing,apply_device_chain,
build_tracks'sidechain_from,capture_stems). An integer, or digits
no track has as its name, are still an index. Checked in Live 12.4.16
(the mixer and an input routing by "808"). - New audio clips play from the file's start in every path, not from
where Live puts the start when warping goes off after its warp analysis
(the file's first transient, up to seconds in; in Live 12.4.16 a 150 s
file's went from 0 to 0.53, and the reset in the same batch held): stems placed byseparate_stems(to_tracks=True)play
from where their (unwarped) source clip does, andgenerate_audio's
clips and the originalcreate_audio_clipfrom the file's start, as
build_tracks' already did. The simulator's Live now moves a new clip's
start, so a path that leaves it is caught. doctorsays how to turn the full profile on in each client (in Claude
Desktop the extension's Tool set, which overrides the environment), and
warns when uv is missing.
Added
- A "Tool profile" option in the Claude Code plugin (
/plugin,
Configure options):fullturns the reference-song tools on without a
shell variable. The plugin passes it asABLETON_MCP_PROFILE_SAVED, so
ABLETON_MCP_PROFILEin Claude Code's environment (the evals') still
wins.
Changed
- The jobs run reference-dissector f192456 (was 11a264c). For the jobs
only itsblueprintstep changed: a locator that rounds to the plan's
end is left out and logged, where it used to fail the job's last step.
Everything else they run writes the same files (plan --live-srand
candidates' per-bar rule are off the jobs' path; the same plan made a
byte-identical blueprint at both commits). - The fake Live, and so the simulator, reports Live 12.4.16, where the
latest measurements were made, and a pad the browser loads has 3 voices
(a Simpler made by path 6), as Live 12.4.16 did on 2026-11-14. - CI fails on Windows too (it has passed there; the jobs' process-group
tests skip). The .mcpb's tool list is always the core profile's, whatever
the shell that builds it says; the release notes take only their own
version's CHANGELOG section (2.4.1, never2.4.10).
Docs
- The checks of 2026-11-14 (
build_from_blueprintin Live, a Simpler's
0.1 ms Fade In, 13 of 13 Volumes, the recordings equal to the browser's
build) ran on Live 12.4.16, not 12.4.6: Live's own log has 12.4.16 first
started that day at 16:02 and 12.4.6 last on 2026-11-08. Corrected in the
2.4.0 notes, README, CLAUDE.md and docs/blueprint-v1.md. - How to turn the full profile on, per client (README, the setup skill);
made_byin docs/blueprint-v1.md (an install names its commit too).
Tests
tests/test_blueprint_readback.py:build_from_blueprintagainst a
simulator made to refuse a file by path (the browser's item of that name
holding another), a choke group, a Volume as a number and as text, and
voices; each is reported and makesokfalse, and a check turned off is
not run. A blueprint passed as an object cuts an excerpt's stems into the
data folder. Before, only the clean read-backs were tested.- Jobs: the runner's heartbeat while a step runs, a runner alive but silent
forSTALE_S(lost, holding the machine), and "invalid choice" skipping
only an optional step.