Repository navigation
The same 89 controls and 387 checks, with changes to 6 checks and 3 controls,
19 more worked examples, one new tool, and changes to 9 tools, the collection
rules and the HIPAA crosswalk.
- Provider encryption statements (DAT-01 A1, A3, A4, A5): a provider's own
statement is needed only for data the company keeps at a provider to use
later (kept data), such as support conversations, customer billing
records, source code or files kept in a provider account. A request the
company's app sends to a provider for an answer (an AI model call, a map
lookup, a third-party sign-in) needs none, even when the provider keeps a
copy to deliver the answer or for its own safety checks, and neither does
data that is public by design or a provider's own records of the company
as its customer. Each use is judged separately. A1 and A3 still need the
statement to name the algorithm, and A3 a key length that meets the
minimum; AES named with no key length meets it, because every AES key is
at least 128 bits. For A4, a provider's statement that the data is
encrypted at rest also covers how the provider stores the keys it holds
for that data. For A5, the same statement covers the rotation of those
keys, and where the company holds no key itself, A5 reads its 12-month
clock from a provider's statement of automatic rotation or of a rotation
in the past 12 months, staying unresolved with none on file. Anything on
file showing those keys exposed, or not rotated, still counts against the
check. The statement comes from what the provider publishes or from a
report or written answer the company already holds; over a Type II period
it is the provider's report covering the period, with a bridge letter for
any gap. Nobody is asked to email a provider or to request a gated
document. Where those are not on file, or do not establish what the check
needs, the check stays unresolved for that provider only: no pass and no
gap, what is already shown stays shown, and the user is asked nothing
more about it. Needing a statement here does not decide which providers
belong in the dependent vendor review. DAT-01's collection guidance in
framework/controls.jsonsays the same, and 12 new worked examples cover
kept data, requests for an answer, and a provider with both. - Vendor report periods (VND-02 A3): a dependent vendor's SOC 2 report also
meets the check when its period ended in the 12 months up to the
examination date (for a Type II, the last day of the examination period),
beside a period that overlaps the examination period or a bridge letter
covering the time since. The check's coverage question and typical
evidence, and VND-02's collection guidance, say the same. Of the check's
two earlier worked examples, the one with report periods that ended two
and eight months before the examination date now passes with no bridge
letter, and the bridge letter one now has a report that ended fourteen
months before. Two new ones: a report that ended fifteen months before,
with nothing covering the months since, is a gap, and a Type II counts
its 12 months back from the last day of the period. - Scan coverage (VUL-01 A1): the check reads "All in-scope scan targets at
the layers the company operates or configures are covered". Those targets
are the company's own code and dependencies, the workloads it deploys and
the hosts or devices it manages. Provider-operated underlying
infrastructure and shared-service internals are outside them, a SaaS
account or admin setting alone does not make a provider's software a
target, and using managed services or having no servers does not remove
the company's own. A repository, project or workload entry covers the
applications or functions deployed from it when system evidence, such as
the scanner's project list or the hosting platform's build settings,
shows that link, and a container image the company builds stays its own
target, base image and installed packages included. Coverage shown only
by a policy, inventory or statement, with no scanner-side evidence,
fails. VUL-01's questions and collection guidance say the same, and seven
new worked examples take the place of the check's two earlier ones. - Worked examples grow from 1014 to 1033, all on the checks above. 356 of
them correct an AI that was too strict and 227 one that was too lenient. - HIPAA crosswalk (
framework/hipaa-crosswalk.json): each row keeps
controls, the controls that carry the requirement, which the prep-phase
HIPAA coverage view counts, and 32 rows gainrelated, further controls
whose own attributes address the rule's text. The report's mapping cites
them after the row's controls, and the coverage view does not count them.
Three links leavecontrols: NET-03 from maintenance records
(164.310(a)(2)(iv)), END-02 from workstation use (164.310(b)) and IAM-01
from automatic logoff (164.312(a)(2)(iii)), and those rows' rationales
name what carries each. 38 rationales and three notes are reworded: they
name the related controls, and they describe the checks they cite as
those checks are written, among them PPL-01, PPL-03, IAM-02, the POL-01
attributes and the checks under 164.312(c)(2). This rewording changes no
check. A scope note explains the two lists, and
method/hipaa-crosswalk.mdshows the narrower control lists. Rows,
citations, names and resolutions are unchanged. - Sending evidence on an audit: where
get_statusorcomplete_step
carriesdata.evidence_send, the files go to the audit team by its send
command instead of a zip.complete_stepthen hands over once every file
has arrived; until then it names the files still to come
(data.evidence_send.owed) and what to do for each, and it takes
cannot_provide, each file the user cannot provide with the user's
reason in their words. There,request_upload_linkmakes no link,
submit_document's audit copies travel at the handoff by the send, and
record_prior_reporttakessaved_sha256, the saved copy's fingerprint,
which the sent report is checked against.method/collection-rules.md
gains the same finish (THE SEND). - The evidence folder: a new tool,
record_folder_copies, reports what the
commands in a reply'sdata.evidence_folder.nextdid: copies of saved
files in the evidence folder (the originals are never moved, renamed or
changed) and the folder's START HERE.txt. It records where the copies are
and whether START HERE.txt is written, and changes no saved file, answer
or score. On an audit,answer_audit_question's one question about files
from readiness holds the handover only while it lists a file that names a
system. It takes nocannot_provide(a file that no longer applies goes
inexcept), and a file it confirms can count as collected once it
arrives unchanged. - Helpers:
delegate_topictakes several topics at once, separated by
commas, for one email with one access link. One person keeps one link,
so more topics for someone who has one are added to it, and a teammate
who is already an admin or member gets no link, only a short note of what
was asked.undo_delegatetakesdelegate_emailto take a topic back
from one person; a teammate keeps access for the topics they still cover,
and it ends once they cover none.get_topic_delegation_statusshows each
person's topics, how many of each topic's checks are done and whether
they have connected their AI, counted from the same checklist the
helper's own AI sees. - Scope answers:
set_company_profilesays whathas_remote_accessand
uses_removable_mediamean. Remote access is a VPN (a mesh VPN counts), a
zero-trust access tool used in its place, a bastion or jump host, a cloud
provider's shell or tunnel service into servers, or SSH or RDP into a
server that runs production, can reach it or holds its keys. Working from
home and signing in only to SaaS tools and cloud consoles is not remote
access.falsemakes IAM-02 A2 and NET-02 A4 not applicable. Removable
media is USB drives, external disks and memory cards used for company
work, andfalsemakes END-02 A3 not applicable. A recorded answer
changes only when the user confirms it is wrong. On a readiness account,
the checks an answer decides follow the saved answer at their next
judgment kit or save, and if progress still counts a check its kit
withholds, the AI sendsreport_problemnaming the check and the answer.