Skip to content

v0.2.2

Choose a tag to compare

@ronluna ronluna released this 10 May 03:23
· 12 commits to master since this release

Fix: Revert incorrect Ketra color temperature implementation

v0.2.1 incorrectly identified LIP action 17 as a color temperature control for Ketra PHANTOM_SPECTRUM fixtures.

Live protocol testing on the HomeworksQS controller confirmed:

  • Action 17 = raw brightness in 0–65279 scale (equivalent to action 1 in 0–100%)
  • No color/CCT control exists via LIP — all tested action numbers (14, 15, 16, 18) and multi-parameter formats return ~ERROR,1

PHANTOM_SPECTRUM outputs (Ketra fixtures) continue to work correctly as standard dimmable lights. Real-time arbitrary color/CCT control for Ketra via the LIP protocol is not possible — it would require LEAP or the Ketra N4 API, neither of which is exposed by this controller.