v2.05-re1: rebuilt application and bootloader
First release of the EEVblog 121GW firmware rebuilt from reverse-engineered C. The binaries are built with GCC 9.2.1 (GNU Arm Embedded 9-2019-q4) and CMake from commit 70c3ee1. Both have been tested on the meter.
Files
| File | Size | What it is |
|---|---|---|
EEVBlog.bin |
92,040 B | Multimeter application v2.05, linked at 0x08006000 (build/firmware/app.bin) |
bootloader.bin |
10,156 B | SD-card bootloader, linked at 0x08000000 |
app.elf, bootloader.elf |
The same builds with symbols, for debugging | |
SHA256SUMS.txt |
Checksums of the files above |
Installing the application
From the SD card: copy EEVBlog.bin to the root of a FAT-formatted SD card and run the firmware update procedure in the manual.
Over SWD: hold the chip in reset and write from 0x08006000 only:
STM32_Programmer_CLI -c port=SWD mode=UR -w EEVBlog.bin 0x08006000 -v -hardRst
Installing the bootloader
The bootloader can't be updated from the SD card. It has to be written over SWD at 0x08000000. Make a full backup of the flash first.
Warnings
- Never erase or write the data EEPROM at 0x08080000. It holds your meter's individual calibration, which can't be recreated.
- Never mass-erase the chip. That wipes the calibration as well.
- The application, in emulation, matches the original v2.05 function by function and as a whole image. One timing difference was found on the hardware and fixed (see
docs/app-architecture.md).