Repository navigation
v0.1.49-beta.5
Pre-releasePrerelease. v0.1.49-beta.5 is a test build for v0.1.49. Do not run it in production. Report problems on GitHub Issues.
Breaking changes
None.
Connector maximum power and maximum current now take decimals. A request that worked before still works. The API reference already types maxPowerKw and maxCurrentAmps in responses as numbers, so a value such as 31.5 stays inside the documented contract. A script that assumes maxCurrentAmps is a whole number should accept a decimal once an operator enters one. OCPI still publishes whole numbers.
Changes
Changes since v0.1.49-beta.4.
Decimal connector power and current
- EVSE create, EVSE edit and Add Connector take a maximum power with up to 2 decimals (such as 7.4 or 11.5 kW) and a maximum current with up to 1 decimal (such as 31.5 A). The smallest value is 0.1. Other values answer 400
VALIDATION_ERROR. - The site import takes a decimal current.
- The CSMS and the driver portal show ratings in the number format of the UI language.
- OCPI locations publish the current rounded down to whole amperes and the power in whole watts.
Docs: Stations, Connectors.
Station Security and Configurations tabs
- The Security Event Log filters fit on one row group on desktop, and the table columns line up.
- The Configurations toolbar fits on desktop.
Docs: Stations, Security, Stations, Configurations.
3D site layout
- The parking lot is paved, with a curb, on grass. Edit Layout has a Parking Lot panel for the spots per row, the rows, the spot size, the lane width, the facing and the transformers. A site without a saved layout shows 2 rows of 10 spots, grown to hold its stations.
- Transformers stand on the grass. Load management links glow from the panels to the chargers and show their limits.
- A bay shows a car while the station charges, a Reserved sign while it is reserved and a traffic cone while it is in maintenance.
- A paired credit card reader shows on the front of its charger, under the screen. The company logo shows on the back panels of the chargers.
- The label of a station shows its state in text, after the station ID, in the state color.
- The 3D view and the 2D view open the same station popup.
- A successful Save leaves Edit Layout. A failed Save keeps your changes and shows the error.
- Rows pair around the lanes, so the chargers of every row stand at the lot edge and face the lane.
Docs: Sites, Layout.
Dashboard Site Layout card
The dashboard has a Site Layout card with a read-only 3D view of one site. Pick the site in the card. Your choice is saved with your dashboard layout. Click a station for its details, or Open Site Layout to edit the layout. You can move or hide the card in customize mode. The card needs the sites:read permission.
Docs: Dashboard, Site Layout.
Fixes
- 1NCE SIMs: a station that reports a 20-digit ICCID now finds its 1NCE SIM. Sessions are built from events in time order, and a Refresh reads each event page once. Docs: SIM providers.
- Metrics collector: a slow collection no longer overlaps the next one. Its 24-hour counts run with a 20 second time limit and keep the previous value when they time out.
- Database indexes: migration 0481 adds an index on OCPP message log action, direction and time, and migration 0482 adds an index on transaction event time. Both serve the metrics collector's 24-hour counts. Migration 0482 drops the OCPP message log action index, which the new index covers.
- Site Layout 2D view: on a phone, the Power Draw panel sits above the board and no longer covers a station.
- Portal location page: a connector row at phone width wraps its type and status instead of running past the row.
Upgrade notes
- Migrations 0481 and 0482 build their indexes concurrently on the
ocpp_message_logsandtransaction_eventstables. On a large install this can take a while. They take no write lock, so stations and sessions keep working during the build. - Installs that ran v0.1.49-beta.3 with 1NCE SIMs may store one 1NCE session twice at the first Refresh after this update.