Skip to content

Modular-Trackular Plus CE_20261120

Choose a tag to compare

@github-actions github-actions released this 20 Nov 18:08
· 50 commits to modular since this release

MT+ CE_20261120: CE's file manager fixes, safer sample import and export

Based on Polyend's Tracker CE main at cf8bd7b. Tracker+ only.

What's new from CE

  • A sample import that fails partway (the file is gone, can't be read, or can't be saved) now frees
    its memory. Before, a later import could be placed past the end of sample memory, which could
    crash the unit or damage files on the card.
  • Opening the Sample Loader, previewing a sample, exporting, and opening the Firmware or Games lists
    now stop a background project save cleanly first, instead of taking it over half done.
  • A project save that fails while writing a sample now shows an error instead of freezing the unit.
  • Export Project Samples no longer writes past its buffer, which damaged the exported stereo files.
  • Song export no longer recreates its file on every write.
  • Importing a cut-off IT or MOD file no longer leaves the file open for the next load.
  • File lists sort numbers by value at any length, with the same order every time.
  • The Firmware list copes with a card that has no Firmware folder, and the "cannot delete" message
    in the file browser shows its text correctly.

Mod changes for CE's

  • None. No mod needed changes for this release.

Mods in this release (each can be switched Off)

  • Humanize 1.0
  • Global Swing 1.0
  • Master FX 2.1
  • Color Song 1.0
  • Variable Track Length 1.0
  • Copy to New 1.0
  • Song Loop 1.0
  • Synths 1.1 (WAVE, PHASE and DCO6)
  • Synth FX 1.1

Install

  1. Back up your card's Projects folder.
  2. Download TrackerPlus_MT_CE_20261120.ptf from this release.
  3. If you haven't installed CE_20261118 or later: download PolyendTracker_CE_Words.zip too, unzip
    it and copy its Words folder to the card's root.
  4. If you haven't installed synths-1.1: download PolyendTracker_CE_Synths.zip too, unzip it and copy
    its Synths folder to the card's root, replacing any older one. Without it, a project's synth parts
    can open on another engine. Delete Synths/GRAIN.psyn from the card if an older release put it there.
  5. Copy the .ptf to the card's Firmware folder and flash it from Config > Firmware > Firmware update.
    Config then shows the version as 1.0.0 MT.
  6. Optional: PolyendTracker_CE_Effects.zip has CE's Sample Editor effects; copy its Effects folder
    to the card's root.

Warning for 1.2.0 users

Projects saved on MT+ (and on CE) don't open on stock firmware 1.2.0: CE saves patterns in a newer
format. Keep a backup. tools/ce_to_120.py in this repository makes a copy of a project that 1.2.0
can open, without the things only CE has.

Tested

  • The emulator's release tier (56 jobs) and the mods' host tests: all pass. CE's own build without
    the mods is unchanged, byte for byte.
  • In the emulator: a project with Song Loop and Master FX on opens and plays with this build.
  • Not checked on a Tracker+ yet: Song Loop playing while the Sample Loader opens and previews, a
    failing import or save, and exports. Details are in the merge commit.

MT+ is unofficial and not affiliated with Polyend. Please don't report problems with it to Polyend.