Repository navigation
To test
andy edited this page Oct 27, 2026
·
101 revisions
Last updated: 2026-10-27 02:00. Hand checks waiting for a person at the screen. An item is added when a fix is merged and removed when it has been checked; anything that fails goes back to its issue. "In build" is the first commit that contains the fix: the package you test must be that build or later.
How to help: anyone can take an item. Install the build named (packages from the latest
CI run on main, or build as in GETTING_STARTED.md), follow
"How to test", and comment on the linked issue: what you did, what you saw, operating system and version, and a
screenshot if something looks wrong.
| Check | How to test | What to look for | Issue | In build |
|---|---|---|---|---|
| Vibrations: Freq. factor | Open any calculation with frequencies, Vibrations, change the Freq. factor to 0,96 (comma), close the Viewer, open it again | The field reads 0.96 after the first entry; after reopening it is back at 1; with 0.96 the line under the spectrum shows both values (… cm⁻¹ (scaled …)) | #604 | v9.4.1 |
| Spin density as tables | An open-shell calculation (e.g. General Chemistry O2), MOs panel, Spin Density | A wrapped note, a SOMO table and a spin population table; nothing runs off the right edge; Compute shows a surface without moving the slider | #608 | v9.4.1 |
| Orbitals follow the scan point | A new ECCE-QM relaxed scan (run it in 9.4.1), Relaxed Scan panel open; open MOs, MO Diagram, Density Map and Density Profile; click point 1 and the last point | Each panel says which point it shows and its orbitals change with the point | #549 | v9.4.1 |
| ORCA dispersion | ORCA Theory Details: Dispersion D3BJ; Verify; then reopen an older calculation whose functional reads "PBE0 D3BJ" and save it | D3BJ on the ! line; the older calculation shows PBE0 with Dispersion D3BJ and keeps it after saving | #593 | v9.4.1 |
| Frequency stage in Progress | Run an ORCA Opt+Freq with an analytic Hessian (e.g. B3LYP/def2-SVP water) and watch the Progress box after the optimisation converges | A Frequencies stage with "analytic Hessian, k of N perturbations" before the job ends | #600 | v9.4.1 |
| Compare Energies | Organizer: select two calculations, Tools > Compare Energies | Both energies and the difference in Hartree, kJ/mol, kcal/mol, eV; a note when code, method or basis differ | #573 | v9.4.1 |
| GROMACS launch messages | GROMACS Dynamics: Dynamics tab, constant pressure on, pressure relaxation time 0.5 ps; Run settings, barostat interval 100; time step 2 fs (the default). Launch | The launch check stops on grompp's warning; the message says 'Dynamics tab, pressure relaxation time (tau-p)' and 'Run settings, barostat interval (nstpcouple)' instead of bare .mdp keys, and suggests a larger relaxation time | #527 | 169c1982 |
| Check | How to test | What to look for | Issue | In build |
|---|