Repository navigation
v1.2.1
rct-manager 1.2.1
Published as a native linux/amd64 + linux/arm64 multi-arch image.
docker pull giiibates/rct-manager:1.2.1giiibates/rct-manager:latest now points at this release.
Changelog
[1.2.1] - 2026-10-16
NewConfigure an Open-Meteo solar forecast in Energy Manager (location search via Photon, production curve preview) with an optional read-only dashboard widget.NewPreview a read-only dynamic charging plan from spot prices, solar forecast, consumption history, battery state, and per-inverter limits. The Dry-Run explains its assumptions and never sends commands to the battery.NewThe Charging plan tab shows the last 60 days of household consumption as a bar chart with the daily average, and the schedule as a full-width time-series chart (grid charge power and target SoC, per-slot tooltip, screen-reader summary). The schedule lists the newest slot first, explains each reason in plain words, shows end dates of slots running past midnight, and stays open on refresh.NewThe usable battery capacity is verified from the module count and the RCT Power Battery datasheet (1.92 kWh per module, 90 % usable), e.g. 10.37 kWh for a Power Battery 11.5. An Expert override takes precedence; capacity is never estimated from Ah and voltage and stays "unavailable" without a verified source.FixThe usable battery capacity is now verified on a single-tower system: module serial slots the scan never reads behind an unanswered slot no longer block the calculation, so the charging plan no longer stays on "could not be verified".ChangeWhile the Charging plan waits for an input (battery state, prices, solar forecast, consumption model), a rotating "Please wait …" spinner replaces the status text and checklist (still shown in Expert mode) and the plan is re-requested every 10 s, at most 30 times. Settings that need action, such as a disabled spot market, keep their text. A device change clears the consumption chart immediately instead of leaving the previous one.NewA "Charging schedule" dashboard widget (off by default, added through Edit dashboard) shows the Dry-Run charging plan of the first inverter as a time-series chart of grid charge power and target SoC, with a per-slot tooltip. It refreshes every 5 minutes like the forecast widgets and shows a short text such as "Spot market disabled" while the plan is unavailable.ChangeThe household consumption section on the Charging plan tab is hidden while there is no data to draw. "Next grid charge" shows Target SoC, Charge power and Total plan grid energy as hero metrics in the Spot Market style.FixBattery modules are counted correctly (every populated module serial slot is one module, so a Power Battery 11.5 shows 6), and the dashboard battery tower is drawn true to size for up to 6 modules.FixThe runtime charging plan no longer waits for consumption history: it falls back to the configured baseline or a median estimate and reports this in the stableforecast_basisandforecast_confidenceenums (shared with the Dry-Run). The preview says "Spot market is disabled" or "Solar forecast is not configured" when an input is off or incomplete.FixSpot prices, bidding zones, and solar forecasts refresh in the background and are served from the database, so opening the admin interface or restarting triggers no provider calls. Failed refreshes show a stale-data warning, and an older refresh cannot overwrite concurrent changes. Spot-price previews assign quarter-hour intervals to the correct local day, including daylight-saving transitions.FixConnection stability: a single unanswered read keeps the connection for other objects, the same object is re-read on a fresh one (a late answer cannot be mistaken for the retry's answer), and a second unanswered read in a row reconnects; a write after an unanswered read starts on a fresh connection; a single-tower inverter no longer drops its connection over second-tower registers; unsolicited responses are logged as one debug "burst started" line plus a per-minute summary (flood limit and reconnect behaviour unchanged); timeout log lines include the parser state and duplicate responses are logged as such.FixRemoving an inverter or changing its address clears its cached readings and the dashboard tower's old module count. Live settings or parameter changes are rejected while another device transition is running.FixOn narrow screens the inverter card header keeps title, status badge, and delete button on one row, and the four energy status tiles stay in one row down to 320 px.SecurityDispatch refuses stale control telemetry before the first setpoint and blocks capability, limit, or policy changes while a restore is pending; direct writes to battery control registers can no longer interleave with an active dispatch command.SecurityThe inverter'slogger_*_log_tshistory objects are read-only; a write allowlist listing one is rejected at startup with the metric name. Logging out clears cached inverter telemetry from the browser.
Built 2026-10-18T16:57:55Z from 28a1c47513e8a6852c43fdcc91deda497fee1f70.