Repository navigation
v1.6.9 (beta)
Pre-release
Pre-release
Fixed
- Interior temperature 10 °C too high: the OBDb formula (A:B / 10) gave 31–32 °C with the climate set to 20 °C; ABRP shows the sensor 1–2 °C above the setting. Now A:B / 10 − 10 °C (log of 2026-11-06: 20.9–22.3 °C).
Flash in the browser: https://idmate-app.github.io/IDTelemetry/flasher/