Fixed
- Shared I2C bus without a lock: the RTC (DS1307) and the motion sensor (MPU-6050) share one bus. The bus driver only locks a single transfer, not the read-out afterwards, so the gyro task (every 100 ms) and the web server reading the clock could get each other's bytes – wrong motion values (which also gate CAN sending) or a wrong time. A common lock now keeps write, request and read-out together. The PMU is on its own bus and not affected.
Added
- Observation for "parked" (DID
0x210E): parked is still recognised by the exact value B = 8. Each value the car sends is written to the syslog once per start (CAN, "0x210E neu"), so the rule can be settled on real data later.
Flash in the browser: https://idmate-app.github.io/IDTelemetry/flasher/