Repository navigation
v0.2.0
xactflow-archidesc v0.2.0
This release moves xactflow-archidesc to ipxact-compiler 0.2.0 and XactFlow 0.3.0, makes
connect_bus() follow more of the IEEE 1685-2022 connection rules, and fixes the importer when
several scripts are run in one process. It contains breaking changes: see "Upgrading" below.
ipxact-compiler 0.2.0 and XactFlow 0.3.0
xactflow-archidesc now requires ipxact-compiler>=0.2.0 and xactflow>=0.3.0. The parameter
overrides given to add_ip() are recorded as ipxact.Expression objects in
component_ref.config_element_values.
Bus connections (#1, #5)
connect_bus()accepts two bus definitions when oneextendsthe other, directly or not, as
link()already did (SCR 2.2) (#5).- A system and a mirrored-system interface are only connected when their
groupis the same
(SCR 2.13). Otherwise the error saystheir system groups differ(#1). - A monitor of a system or mirrored-system interface needs the same
groupas the interface it
watches (SCR 4.4).
Parameter values (#7)
add_ip() raises ValueError for a parameter value that is not a usable expression: an empty or
blank string, or a float that is not finite (nan, inf).
Importer (#2)
The modules a script imports from its own folder (a helpers.py next to it, for example) are
forgotten once the script has run. A second script in another folder no longer gets the first
script's helpers. Packages installed below the script's folder, in a .venv for example, are
left alone. If the script fails, its own error is the one raised.
Type hints (#6)
The package ships py.typed, and its type hints now pass mypy. CI runs mypy on every supported
Python version.
Documentation (#3, #4)
- The
.texformat description useslink()instead ofelaborate(), like the.md(#3). - The worked example of the format description names the interconnect ports, so it no longer
fails with "more than one possible pair", and its interconnect VLNV has all four fields (#4). - The format description and the README describe the new connection rules.
Upgrading
ipxact-compiler>=0.2.0andxactflow>=0.3.0are required. See their release notes for their
own breaking changes.config_element_valuesholdsipxact.Expressionobjects instead of strings. Use.valueto
get the text.connect_bus()now refuses connections it used to accept: a system and a mirrored-system
interface with different groups, and a monitor whose group differs from the system interface
it watches.add_ip()now refuses empty, blank and non-finite parameter values.- With xactflow-design 0.2.0, the exported design file is named
<vendor>_<library>_<name>_<version>.xml, for exampleexample.org_soc_example_0.1.xml.
Full Changelog: v0.1.1...v0.2.0