Skip to content

Releases

22.13

Choose a tag to compare

@IharBild IharBild released this 23 Nov 17:08

Full Changelog: https://github.com/IharBild/rtlsdr-wwb-scanner/commits/v22.13

Release V22.13 — 23 November 2026

Branch: [v4-fixes](https://github.com/IharBild/rtlsdr-wwb-scanner/tree/v4-fixes), commit b3d6e75

Two changes are visible right away: "Own gain per band" is on by default, and the dongle library scanner-v8 (libusb 1.0.30) is now the default. The rest closes the remaining items of the external audits. Raw scan data, spur hiding, units (dBFS/Hz), factory settings and the WWB CSV / sdb2 / sdb3 / WSM formats are unchanged.

This release also carries V22.9–V22.11. The tag v22.11 was made on master (the original upstream code), so V22.9–V22.11 reach users first with this release.

User-facing changes

V22.12 — own gain per band on, driver v8

  • "Own gain per band" is on by default. Each band is scanned at the gain that gives it the lowest floor. A higher gain is kept only when the noise really drops by at least 1 dB, and levels are brought back to one scale.
    • On the V4 the floor dropped by about 4 dB on 470–560 MHz and by 7.9 dB on 174–240 MHz. The levels of strong signals stayed the same.
    • An installation that already has saved settings switches it on once and says so in the status line. Switch it off in Scan settings if you need one gain for the whole scan; it then stays off.
    • Bands without a floor calibration at the higher gains are not raised. Make a floor calibration without antenna at those gains first.
  • Dongle library scanner-v8 by default. It has the same code as v7, built with libusb 1.0.30, which fixes CVE-2026-47104 and CVE-2026-23679. The portable build ships it. For a Python installation run python drivers\rtlsdr-scanner-v8\install_dll.py.

V22.13 — rest of the external audit

  • Chart: a scan of 15 001 points is no longer drawn as 7 501. One missing tile is drawn as a gap. The number of chart points follows the real point spacing, including Window sizes other than 25 kHz.
  • History and files:
    • the weights of points measured again or marked as dongle products are kept in the history, .npz and JSON;
    • .npz keeps the time of the scan (before, an imported .npz showed the time of import);
    • a scan with an empty set of passes, and a file without pass times, can be read;
    • a damaged history index is put aside and a new one is started. A file that is only busy, for example held by an antivirus, is never replaced with an empty one;
    • a damaged sdb3 header error names the file.
  • Bands of lost sensitivity use the tile keep ratio from the settings instead of a fixed 0.39.
  • On Windows, a dongle library that is not the scanner build is named in the status line. With it the PLL lock check does not work, and tiles can be measured at a wrong frequency without warning.

Also included (first released here)

  • V22.11 — hardening after the external audits.
    • Atomic export.
    • Windows device names (NUL.csv, COM1.sdb2) are refused.
    • sdb3 and WSM CSV carry the time of the scan, and import restores it.
    • The CRC of each sdb3 sweep is checked: a wrong checksum gives a warning and the data is still read.
    • Import limits: 512 MB and 20 million points.
    • The portable build includes LICENSE and a GPL / source section. Its SHA-256 is published next to the zip.
  • V22.10 — noise check, IF filter, 25 kHz points, own-kit comb.
    • A higher gain per band is kept only if the noise drops by at least 1 dB.
    • The IF filter is limited to 2.4 MHz.
    • The window size follows the sample rate, so points stay 25 kHz wide.
    • The comb from your own kit (laptop, power supply, USB; lines at multiples of 4.15996 MHz) is hidden the same way as dongle spurs.
  • V22.9 — reliability.
    • The dongle is no longer closed during an active USB call.
    • Opening the dongle times out after 20 s.
    • Gain, sample rate and frequency correction are checked before the dongle is opened.
    • The history copes better with concurrent access and damaged records.

Install / update

Portable (Windows, no Python): WWB-Scanner-22.13.0-win64-portable.zip is attached to this release by GitHub Actions about 10–15 minutes after publishing; its SHA-256 is added below.

  • Before unpacking: right-click → Properties → Unblock.
  • To keep your history and calibrations, copy the data folder from the old portable folder into the new one.

Python installation (Python 3.11+):

python -m pip install --upgrade --no-deps ^
  https://github.com/IharBild/rtlsdr-wwb-scanner/archive/refs/tags/v22.13.zip
python drivers\rtlsdr-scanner-v8\install_dll.py

Run the second command from an unpacked copy of the source zip of this release.

Checked

  • On the RTL-SDR Blog V4, Windows, Python 3.13, DLL scanner-v8:
    • qa_pc standard run of V22.13: 0 FAIL (222 PASS). Full scan 31–1766 MHz took 153 s.
    • The one-time switch-on of "Own gain per band" was checked in the window.
    • Earlier runs of V22.10+11 and V22.12 also gave 0 FAIL.
  • Files on Windows:
    • Wireless Workbench 7.9 opens our sdb2 and sdb3 with the scan date and shows the 600–610 MHz gap as no data.
    • WSM 4.9 opens our CSV with the scan date.
    • Export and import keep the scan time in all formats.
  • Dongle: 300 opens and closes in a row with no error and no handle leak (154 → 156 handles). Opening takes about 1.3 s.
  • Automatic tests: 1027 passed each on Python 3.13, Python 3.11 and with the USB model, 0 failed. CI is green on Linux and Windows. The portable build passed --selftest on Windows in CI.
  • Not checked: the 22.13 portable exe with a dongle on a desktop PC. Unplugging the dongle during a scan (qa_pc --unplug) has not been run.

Roll back

  • Python installation: install the tag 22.8 with the same command (.../archive/refs/tags/22.8.zip).- DLL: run python install_dll.py rollback in drivers\rtlsdr-scanner-v8; the previous library comes back.
  • Portable: delete the folder. Nothing outside it is changed.

По-русски.

  • «Own gain per band» включено по умолчанию. Пол на V4 ниже примерно на 4 дБ (470–560 МГц) и на 7,9 дБ (174–240 МГц). В установке с сохранёнными настройками оно включается один раз, отключается в Scan settings.
  • Библиотека донгла scanner-v8 (libusb 1.0.30, исправлены две уязвимости libusb) — теперь по умолчанию, в портативной версии тоже.
  • Остаток внешнего аудита: график больше не теряет точки, веса точек и время скана сохраняются в .npz, испорченный индекс истории не губит занятый файл, чужая DLL на Windows называется в строке состояния.
  • В этот релиз входят и V22.9–V22.11: тег v22.11 был создан на master, поэтому эти версии выходят впервые только здесь.
  • Проверено на V4: qa_pc — 0 FAIL, полный скан 153 с; файлы открываются в WWB 7.9 и WSM 4.9.
  • Портативный zip прикрепится к релизу сам через 10–15 минут после публикации.

SHA-256:

d06833eab486724e0a8b76449d703986ae91880a8b830abc8a8073b7237cfde6  WWB-Scanner-22.13.0-win64-portable.zip