Offline Analysis: recorded numeric excerpts (Linux x86_64)
Pre-releaseThis experimental Linux x86_64 release adds exact recorded numeric excerpts to the ordinary CaptureSuite QC report. It is built from merged source 38edc6e (PR #179), including earlier dependency notices, early QC warnings, IMU feature support, and PR #177 EMG sample-index continuity warnings.
The report shows the first 256 sample frames and first six channels of a successfully decoded numeric stream. Each lane labels its independent amplitude scale and descriptor units. Dashed lines mark recorded batch boundaries. The horizontal axis is sample position, not time. Expand the source disclosure for MCAP/message identity and unchanged native timestamp integers. QC still checks all later messages.
Download and run
Download capturesuite-analysis-numeric-excerpts-linux-x86_64.tar.gz and SHA256SUMS from this release.
sha256sum -c SHA256SUMS
tar -xzf capturesuite-analysis-numeric-excerpts-linux-x86_64.tar.gz
cd capturesuite-analysis
./capturesuite-analysis --version
./capturesuite-analysis qc examples/numeric-force.mmsession --inspect-payloadsOpen the emitted job directory's reports/qc.html in a browser. The included example is clearly labeled simulated force data stored in genuine protobuf MCAP: a narrow excursion, a flat-to-step channel, 512 frames, and a visible 256-frame excerpt limit. To inspect your own session, replace the example path with its .mmsession directory.
The package includes the executable/runtime, source commit pin, QUICK_START.md with exact help/QC/later-window plots commands, usage/limits, dependency terms and the simulated example. The attached desktop and phone screenshots show the actual report generated by the standalone executable.
Supported scope and limits
Tested on Ubuntu 24.04 x86_64 with glibc 2.39; no Python installation is required to run the archive. Other Linux distributions are unqualified. This is not a Windows capture/desktop release.
Numeric excerpts cover only generic.numeric_batch/1, at most 256 leading frames and six channels. They do not show later events, hidden channels, or elapsed gap duration. EMG/IMU retain their existing decoded checks. Use the report's warnings and gap table when judging continuity. A readable trace does not establish full-recording quality, sensor calibration, physiological validity, or physical synchronization. Simulated data is not hardware qualification.
Source and verification
Exact source: 38edc6e
Change: #179
Reproduce the executable with scripts/build-analysis-linux.sh from this pin using the declared Python 3.12 package dependencies, mcap and PyInstaller. The archive additionally includes the tracked docs/NUMERIC_QC_EXCERPTS.md and the attached simulated example.
Astra-Lumen reviewed the change and ran 63 focused real-MCAP/payload/QC/gap/EMG-index tests, Ruff and diff checks on the fleet. The standalone executable completed the example outside the checkout with its Python environment removed; a clock rewind after the retained excerpt failed with strict exit 2 and produced no successful preview. The HTML was inspected at 1440px and 390px with no phone document overflow. An independent actual-use review is tracked separately; no independent verdict is implied here. GitHub Actions were not used.
Downloaded release use
Astra-Lumen downloaded this published archive on hamon-research-168, verified its SHA256 and source pin, extracted it, and ran it with no Python on PATH. Numeric QC completed with exit 0; a later clock rewind and a missing EMG sample-index span both returned strict exit 2. Raw source hashes and native timestamp integers were preserved. The attached report images were regenerated from that downloaded binary at 1440px and 390px; the phone document had no horizontal overflow. DOWNLOAD_USE.json records these observed results.