Skip to content

Recorded numeric sample export — experimental Linux

Pre-release
Pre-release

Choose a tag to compare

@Jacob-Met Jacob-Met released this 10 Nov 19:33
f6e525a

Recorded numeric samples are now reusable

The maintained session exporter and native Export dialog now include generic numeric recordings that were previously omitted. Export every recorded channel/frame into CSV with exact original device timestamps, separate MCAP log/publish clocks, channel labels, units, and copied stream/gap provenance.

This experimental Linux x86-64 standalone CLI includes the cumulative offline QC, feature/plot, saved-job, comparison and selected-feature commands at exact source f6e525a. Numeric sample work merged in PR190, merge15753a5144f40632d3660cf5db3618f4d74d59b7. The source also updates the native Qt Export dialog; a packaged desktop is not included in this Linux CLI archive.

Run

Extract capturesuite-analysis-numeric-linux-x86_64-f6e525a.tar.xz, then:

./capturesuite-analysis/capturesuite-analysis --version
./capturesuite-analysis/capturesuite-analysis export-session recording.mmsession exported-samples --modalities numeric --verify

No Python installation is required. Built on Ubuntu24.04 x86-64; requires compatible glibc/system libraries. Read the included NUMERIC_SAMPLE_EXPORT.md before importing nanosecond timestamps into a spreadsheet.

SHA-256: f1d2f8f37764e6f65b23fdab840aef300440459342e988d86791b3d94b04da8c.

Evidence and limits

Producer astra-lark-61c2 ran62 focused real-protobuf-MCAP/native/export regressions and lint checks on fleet339. Independent astra-tern-93ab used an unfamiliar16-value recording and the actual X11 Export dialog, then the exact frozen executable. Accepted exact >2^53 timestamps, Unicode/quotes, separate reset anchors, missing-clock blanks, NaN/backward-step counts, copied gap declarations, original-source hashes and malformed-input refusal. CSV outputs from the frozen binary matched the independently accepted course byte for byte. Included screenshots are Tern's actual native-dialog use; they show source desktop capability, not a bundled desktop.

The measurements used for this course are synthetic values stored in real MCAP. There is no physical instrument, calibration or multi-device synchronization claim. Derived session estimates use native within-batch deltas only; missing clocks stay unknown. Samples inside declared gaps remain present alongside gap provenance; no repair or resampling occurs. Malformed selected input fails without a successful manifest, though partial CSV may remain.

The archive contains exact installed dependency notices and licenses. Original captures remain unchanged.