This release adds a bunch of new features, bug fixes and some redesigned UI components.

Features

Fixes

  • Fix defrost EEPROM parameters start threshold ranges by @Jordi1990 in #287
  • Prevent changing working mode while defrosting by @Jordi1990 in #285
  • Add compressor limitation when reaching max discharge temperature or pressure by @Jordi1990 in #293
  • Add wait for 3-way valve relay state to change when switching the relays by @Jordi1990 in #296
  • Fixed pump P1 not stopping properly in some conditions by @Jordi1990 in #299
  • Start the compressor from the pump cycle when emergency mode is switched off by @Jordi1990 in #343
  • Keep the minimum compressor on time in the heating backup heater state by @Jordi1990 in #342
  • Keep the pump running while the compressor waits for its minimum off time by @Jordi1990 in #340
  • Resume heating and cooling right after a DHW run by @Jordi1990 in #341
  • Increase maximum backup heater degree minutes threshold to 600 by @Jordi1990 in #333
  • Stop the compressor when emergency mode is enabled while it runs by @rspaargaren in #328
  • Switch the pump P0 relay off when maintenance mode starts during DHW by @Jordi1990 in #345
  • Let maintenance mode finish an oil return cycle and stop DHW too by @rspaargaren in #329
  • Average outside temperature for heating curves and hold it during defrost by @rspaargaren in #315
  • Wait for a minimum compressor off time before starting DHW by @rspaargaren in #319
  • Detect a compressor that the outdoor unit stopped by itself by @rspaargaren in #321
  • Fix pump run and interval timers across millisecond rollover by @shady in #311
  • Recognise HP-S 95 units that report model code 160 by @rspaargaren in #318
  • Fix boot loop on Waveshare displays caused by LVGL theme re-init by @mberntsen in #302
  • Fix WiFi settings saving the signal strength as part of the SSID by @mberntsen in #303
  • Fixed pump waiting on interval before starting after power cycle or maintenance mode switch by @Jordi1990 in #306
  • Run pump P1 only with P0 cycles during frost protection by @Jordi1990 in #309
  • Recalculate both heating curves when a curve setting changes by @rspaargaren in #332
  • [ui] Merge LVGL update actions into lambdas to save internal RAM by @Jordi1990 in #271

Changes

New Contributors

Full Changelog: 0.8.2...0.9.0