Repository navigation
MechControl v2.1.0
This release makes the thermal failsafe more dependable, shows why a control is unavailable on your model, and fixes several readings and profile-slot problems. Settings and profile slots from v2.0.0 carry over.
Download
MechControl-win-x64.zip. This release has no separate build with the mcctl command line.
Thermal failsafe
- The GPU power cut is now sent even when the NVIDIA driver cannot be read at the moment of a trip (GPU asleep or driver restarting). Before, it was skipped.
- If the laptop's embedded controller resets during a GPU restart while the failsafe is tripped, the reduced limits are written again at once. Before, they could be missing for up to about a minute.
- An error while reading a tab no longer closes the app, and the failsafe with it.
- A firmware Turbo preset that raised the CPU temperature limit above the supported maximum no longer blocks the CPU part of the failsafe.
Unavailable controls
Controls that MechControl holds back on your model are now shown greyed out with the specific reason, instead of hidden. An "open an issue" link beside the reason starts a GitHub report filled in with your model, baseboard and CPU.
Fixes
- GPU fan speed: 43 models read part of it from the wrong place, so it could be off by up to about 250 RPM. Not yet confirmed on those models' hardware; please report a reading that looks wrong.
- Stale tabs: after several quick changes, the Power tab's advanced section and the Fan Control tab could keep showing old values.
- Profile slots: saving a slot while a feature was unavailable stored placeholder values that could be applied later. That part is now left empty, and loading the slot says which parts it skipped.
- Firmware Defaults no longer touches GPU power, fans, battery mode or the logo light when that feature is disabled on your model.
- Logo light: if its settings fail the startup check, it is disabled with the reason instead of being written anyway.
- Sliders refuse a value outside the supported range instead of changing it to something else.
- Unrecognised laptops: a firmware setting the app needs is now written only after the model has been identified.
- IDY_7Y: changing a fan curve no longer touches a neighbouring controller bit that the firmware uses for a power-button request.
- Battery tab: laid out in sections like the other tabs.
Lighter and simpler inside
- MechControl no longer depends on Windows' ICU library.
- The code was reorganised to be easier to read and contribute to, with more automated checks on how the failsafe behaves during GPU operations. This part is meant to change nothing you can see.
Upgrading
- From v2.0.0 or the C# v1.6.0: exit MechControl from the tray, then extract the new zip over its folder. See the included
README.mdfor details. - From a C# version older than v1.6.0: a profile slot with a failsafe trigger below 50 °C has to be saved again, and a failsafe trip recorded by that version is not restored.
- Hand-edited JSON files must be plain UTF-8. Comments are allowed, trailing commas are not.
- Custom model profiles:
verified,writeAllowlistandskipVerifyare no longer used.
Testing
Tested on hardware only on the MECHREVO IDY_7Y (board X6AR55xY, Intel, RTX 5090 Laptop), including a real failsafe trip under full GPU load on a build from just before the Battery tab change. Other models load profiles built from OEM data. If something doesn't work on your model, please open an issue and attach mechcontrol.log or a --diagnose report.