Skip to content

MechControl v2.3.1

Choose a tag to compare

@Liddo-kun Liddo-kun released this 14 Nov 02:50
· 110 commits to 426b878c339d01c4a5fc955d8692d0df1706a19d since this release

This release makes mechcontrol.log and the diagnostic report include a read-only copy of the EC's memory, so a report from an untested model has what is needed to answer it. Nothing else changes. Settings and profile slots from v2.3.0 carry over.

Download

MechControl-win-x64.zip. This release has no separate build with the mcctl command line.

EC memory in the log and the report

  • Log: the first session of a new mechcontrol.log records EC memory 0x300 to 0xFFF as hex, before MechControl writes anything to the EC. The log always keeps its first session, so the dump stays in the file you attach to an issue.
  • Report: MechControl.exe --diagnose report.json records the same memory in the report (ecRam) and in its log session, every time it runs.
  • Read-only: the dump only reads. On the IDY_7Y the whole diagnostic run takes 0.3 seconds, and the dump adds about 6 KB.
  • What it contains: the EC's registers and tables, such as power limits, fan tables, feature flags and battery data. The battery data includes the battery's maker and identification bytes. Addresses below 0x300 are left out: MechControl uses nothing there, and one analysed firmware keeps its keyboard-controller working data there.
  • Existing installs: a log that already has sessions does not get the dump on its own. Run MechControl.exe --diagnose report.json instead; it can run while MechControl is running.

Upgrading

Exit MechControl from the tray, then extract the new zip over its folder. See the included README.md for details.

Testing

The release was built from the tagged commit and passes the automated checks, which use synthetic hardware. The dump was run on the MECHREVO IDY_7Y (board X6AR55xY), the only model MechControl has been run on.

Not tested: the dump on any other model. It stops at the first address the EC driver refuses to read and logs where. If a feature is greyed out or misbehaves on your model, please open an issue and attach mechcontrol.log or a --diagnose report.