Repository navigation
Releases
SerialFlow 0.9.0 beta 2
SerialFlow 0.9.0 beta 2: commands that arrive split across serial reads now always work, the terminal behaves like a real one with CR and cursor moves, and a long list of new features: the device can save captures, dashboards can sound alarms, ports follow their USB serial number, and graphs and dashboards pop out to their own window.
- Not code-signed — please read before you install. This pre-release is not signed with a code-signing certificate, so Windows cannot confirm who made the installer or that nobody changed it after it was built. What that means for you:
- SmartScreen ("Windows protected your PC") warns but lets you choose: click More info → Run anyway.
- Smart App Control (Windows 11; Windows Security → App & browser control → Smart App Control) blocks the installer when it is On, and offers no way past it. The only way is to turn Smart App Control Off. We do not ask you to: that removes this protection for every program on the PC, not only SerialFlow, and on many Windows 11 PCs it cannot be turned on again without resetting Windows. If Smart App Control is On on your PC, the safe choice is to wait for a signed version (planned, no date yet).
- If Smart App Control is in Evaluation mode, Windows may switch it On later by itself. Then it may also stop an installed SerialFlow from starting, or block an update.
- To be sure your copy is the one we built, download it only from here or from https://lizerd.se/serialflow/, and compare its fingerprint: in PowerShell run
Get-FileHash .\SerialFlow-win-Setup.exe. It must showD02CA1E2E30C51AB77D0A67EBDC6FAC8CB7D933427E1F01F3A77DBF0B7BE297C.
- Update: beta 1 offers this version at start-up; click Install and restart. Settings, profiles and the Demo folder are kept.
- Found a problem, or missing something? Open an issue.
New
- A simpler first start: a new install opens a small window in the middle of the screen with the terminal and the Quick Send Bar only. Every other pane is one click away (☰ → View or the toolbar) and docks in its usual place. An install you already have keeps its layout.
- Device commands that save data (opt-in, Settings → Device Captures):
~SvLog[:label]saves the terminal log,~{A:W[:label]}saves a graph (.sfplot / CSV),~LogOn/~LogOffstart and stop the Data Logger,~RecOn/~RecOffthe Data Collector. A new Saved Captures pane lists every file and opens it. - Alarms on dashboards: thresholds can watch the value or the min / max / average over the last N seconds, wait N seconds before they trigger, use hysteresis, and play a WAV or MP3 sound (once or repeating) with Mute and Acknowledge. Thresholds now colour every widget, also value displays, gauges and bars.
- Ports follow their device: SerialFlow remembers each port's USB serial number and finds the device again when it comes back under another COM number. The Port Details Connect by Serial # button works.
- Pop out: graphs, dashboards and canvases open in their own window or full screen with one click (also in every tab's right-click menu).
- Graphs:
~{G:X:R:min:max}fixes the X range (Frame and XY graphs stop refitting),~{G:X:E:1}draws XY plots 1:1,~{G:X:L:label:unit}names the X axis. Note: beta 1 reads any~{G:X…}as "delete the graph". - Canvas charts (Sparkline, Multi-Signal Trend, Live Bar Chart, Histogram, XY Plot) get a Chart tab in Widget Settings: grid lines, values and titles on the axes, an X axis in seconds, a fixed scale (Range Min / Max) and one shared scale for all trend traces. The XY Plot now plots its X signal against its Y signal (beta 1 ignored the second binding), the Live Bar Chart draws one bar per bound signal, Value + Timestamp shows the time, the canvas grid shows in edit mode, Rotation and a border (Widget Settings → Appearance) are drawn, Align ▾ lines up and spaces out the selected widgets, Label Position works, and Canvas Properties has size presets.
- Graphs: a colour picker for each signal in the sidebar, and a colour set in Signal Manager now also applies after a restart; the Markers panel has a Graph choice for Add X, Add Y, At Max and At Min; every export format (JSON Lines, JSON, .sfplot too) keeps to a selected range.
- Canvas dashboards reopen after a restart (☰ → Open Canvas Dashboard… opens or deletes any saved one), have resize handles, a working Image widget, background-picture stretch and gradient fill, and Export / Import Canvas (.sfcanvas) with the pictures inside. F5, Ctrl+S, Ctrl+Z work in a focused canvas.
- 32 new canvas widgets (67 in all): Statistics Panel, Rate Meter (readings per second), Totalizer, Value + Trend, Semicircle Gauge, Segmented Bar, Battery Level, Traffic Light (from the alarm rules), Annunciator Panel (a lamp per signal), Data Alive (red when the device goes quiet), Step Chart, Area Chart, Radar Chart, Donut Share, Event Log (every alarm switch with the time), State Text (0 = Idle, 1 = Running …), Arrow, Fan / Pump (turns while running), Attitude Indicator (pitch and roll), Peak Hold (highest and lowest of the last seconds), Duty Cycle (how much of the time a pump ran, and its starts), Zone Gauge (the alarm rules as coloured bands), Bullet Gauge (a value against a target), Alarm Counter, State Timeline, Heat Grid, Trend Grid (one small trend per signal), Polar Plot (angle and radius), and a new Control group: Send Button, Toggle Switch, Send Slider and Number Entry. The four Control widgets are the only ones that send to the port: a text with the value in it (
SET {value}) or hex bytes, only in run mode, only on a click or key, only while the port is open, and they ask Send "SET 42" + CR LF to COM5? first unless that is switched off. Every other widget only displays. - Macros: keyboard shortcuts run the macro on the active port; Import / Export buttons. Auto-reply: an editor for delay, one-shot, case, hex and the reply's line ending; the Matches column updates live and counts failed replies.
- Signal Manager: every override rule is edited in its row (graph, signal, limits, action, factor); the Setup Wizard builds working rules. Decimation MinMax and Average now work (MinMax keeps each window's lowest and highest value, so peaks stay visible), two overlapping rules show a warning that says which one wins, and Details… edits an init override's X axis and per-signal overrides and a manual definition's signals.
- Search: a regular-expression switch (.*), Enter / Shift+Enter step through matches, the Search panel scrolls to its matches. Keyword Highlighter rules can match whole words only, or a regular expression.
- Signal Lines shows the real CTS / DSR / DCD / RI and sets DTR / RTS.
- Hidden Views: right-click any tab or pane title, or open ☰ → View → Hidden Views, for a list of every hidden pane of every port and every hidden graph, dashboard and canvas. Click one to bring it back, or click Close All Hidden Views at the top to empty the list: extra views close, graphs and dashboards the device made are removed, canvases close (their files stay), and the panels every port has just leave the list. It asks first when something closes.
- The usage-count question has friendlier words, and the same promise: one anonymous count a day, no ID, nothing about your devices or data. If you say no, SerialFlow asks again 14 days later, and every 14 days after that; tick Don't ask me again to end it. Turning the counts off in Settings → About is final.
- Software rendering for PCs where SerialFlow's window stays blank: Settings → About, or start with
--software.
Fixed
- A graph line or status line split across two serial reads was shown as text and its sample lost (common on real hardware at high rates).
- A dropped binary graph frame (wrong CRC, bad encoding) left no trace: it now counts in Err: and shows in the RX Error Collector with the reason.
- Signal 32 of every graph was dropped.
- A lone CR now returns to the start of the line (progress bars);
ESC[Kclears from the cursor; text after a cursor move overwrites. Settings → Communication → RX Line Ending works (CR for CR-only devices; LF restores the beta 1 behaviour). ~InLi/~DeLino longer blank the lines they move; colour tags<R>…</R>draw in colour; a stray NUL byte no longer swallows the text after it.- Line numbers keep counting past Max Lines; bookmarks stay on their line after Clear; the bookmark icon no longer covers the first column;
░▒▓blocks sit on their own line; the horizontal scroll bar moves the text. - Settings → Terminal font, size and ANSI colours are applied; keyword rules reach new status windows and ports at once.
- Logger traces no longer show short spikes that are not in the data; delayed playback runs at the rate in its
DELAY:header. - A Streamer graph with a time X no longer looks empty: its window spans what the buffer holds. Event labels move clear of the legend in narrow panes.
- Auto-reply no longer skips lines when many arrive at once (a test file, a fast device): it kept only the last 1 024.
- Data Logger: a line that arrives in two reads is logged once, whole; csv files have a header, the receive time and a line count; txt lines can carry the time.
- Settings and other large windows fit on a laptop screen at 125 % and 150 % scaling (OK and Cancel were under the taskbar).
- A panel dragged in among the terminal tabs and closed there no longer leaves an empty tab behind that shows an error when clicked.
- Switching profiles with two ports open now really switches the window to the profile's layout. Before, the window kept the old panes, and a new canvas dashboard did not show until Reset Layout. Panes the profile's layout does not know (such as the second port's) start hidden, and a new canvas dashboard opens in front.
- With two or more ports open, a port's...
SerialFlow 0.9.0 beta 1
The first public preview of SerialFlow: a serial terminal for Windows that starts as a compact UART logger and grows into real-time graphs, live status windows and dashboards, driven by plain-text output from your firmware.
- Download:
SerialFlow-win-Setup.exebelow. Windows 11, 64-bit; Windows 10 should work but has not been tested yet. It installs for your user account only, and .NET is built in. - "Windows protected your PC"? The installer is not code-signed yet. Click More info → Run anyway.
- No hardware at hand? The installer brings demo files: ☰ → Test → Load Test File →
Demo→showcase_preload.txt. - Updates: SerialFlow checks for a newer version at start-up and installs it in one click. You can turn this off in Settings → About.
- Found a problem, or missing something? Open an issue. A free GitHub account is enough.
Product page, quick start and examples: https://lizerd.se/serialflow/
SerialFlow-win-Portable.zip is a copy that runs without installing (it does not update itself). The other files are the update feed that the app reads.