Skip to content

Releases

v2.2.0-beta.1

v2.2.0-beta.1 Pre-release
Pre-release

Choose a tag to compare

@ihancock ihancock released this 09 Oct 19:17

Changes since v2.1.0

  • Releases: tags with a hyphen are prereleases that testers can install
    A tag such as v2.2.0-beta.1 is published as a GitHub prerelease, so it is
    not "latest" and the public one-line installer keeps installing the last
    stable release. build-bundle.sh points the get.sh published with a
    prerelease at its own bundle, and get.sh accepts LOCONET_VERSION for any
    specific release. The notes of a stable release run from the previous
    stable release, betas included.
  • Installer: ask whether LocoNet is reached over USB serial or TCP
    From a terminal, install.sh now asks which transport to use (defaulting to
    what is configured), then either lists the serial devices as before or asks
    for the LocoNet server address (host or host:port, validated). Choosing a
    serial port, by prompt or --serial-port, comments out an active LOCONET_TCP
    line so the TCP setting can't silently override it. --serial-port and
    --loconet-tcp still skip the questions.
  • LocoNet over TCP: share the DCS52 with JMRI instead of fighting over the port
    LOCONET_TCP=host[:port] makes the gateway read and write LocoNet through a
    network server instead of the serial port, so JMRI keeps the DCS52 and both
    run at once. LOCONET_TCP_PROTOCOL is "lbserver" (JMRI's LocoNet Server /
    LbServer: RECEIVE and SEND lines of hex bytes, the default) or "raw" (a plain
    byte stream, as a serial-to-network bridge gives).
    The diagnostics cover it: connection refused (server not started), host not
    found, unreachable, a server that does not greet like JMRI's, and a
    connected but silent one; the JSON reports the transport and the server's
    VERSION line. install.sh gets --loconet-tcp.
  • Diagnostics: say in plain words why the gateway can't reach LocoNet
    Publishes retained JSON on track/gateway/diagnostics: version, a status
    (ok, connecting, no-device, permission, busy, open-failed, no-answer, lost)
    and a message naming the likely cause. The serial port is now opened
    exclusively so a program already holding it (JMRI) is reported as busy
    instead of both reading half the data; a command station that never answers
    slot 0 is reported with what was heard (nothing, garbled data, other
    traffic) and any JMRI process found. DIAG on the command topic republishes
    with fresh counts. The version comes from a VERSION file written by the
    bundle build and deploy.sh.

v2.1.0

Choose a tag to compare

@ihancock ihancock released this 08 Oct 14:40

Changes since v2.0.1

  • Locomotive control: read every slot, take, drive and release locos over MQTT
    SLOTS reads the command station's locomotive slots; LOCO takes a loco and
    LOCO S/D/F/ESTOP/REL drive it (F0-F28; F9-F28 are DCC packets whose
    state the gateway keeps).
    Every loco in a slot is published retained on track/loco/status/ and kept
    current from every throttle on the track.
    The gateway keeps held slots alive and stops held locos on EPO or when no LOCO
    command arrives for LOCONET_LOCO_TIMEOUT seconds.

v2.0.1

Choose a tag to compare

@ihancock ihancock released this 07 Oct 17:03

Changes since v2.0.0

  • Remember the block detector list across restarts
    • The detector list an app sends ("BLOCKS 100-114") is saved in /var/lib/loconet-gateway/blocks
      and restored at startup in preference to LOCONET_BLOCKS, so after a restart a power cycle
      still knows which silent blocks to publish as occupied, without an app having to reconnect
      first. Delete the file to go back to LOCONET_BLOCKS.
    • The service unit gets a StateDirectory so this works under ProtectSystem=strict.
    • The power-cycle summary logs which blocks reported and which were taken as occupied.

v2.0.0

Choose a tag to compare

@ihancock ihancock released this 07 Oct 16:13

Changes since v1.2.1

  • Gateway 2.0: one command topic, retained blocks, emergency stop, BDL716 reads
    • One command topic, track/cmd, for everything (was track/turnout/cmd and track/sensor/cmd).
      Breaking: apps and scripts must publish there. Turnouts are still "42:T", "42:C", "42:Q";
      bare "Q" refreshes detectors and bare "P" power-cycles the track.
    • Block occupancy is also kept per block, retained, on track/block/status/, so a client
      that connects (or an app coming back from the background) gets every block's last state.
    • "BLOCKS 100-114" tells the gateway which sensors are block detectors, so apps configure
      it; LOCONET_BLOCKS is only the starting value. The power cycle logs what it published and
      warns when it has no detector list.
    • Emergency stop: "EPO" cuts track power at once and latches it off, refusing power cycles,
      until "RESTORE". Track power is published retained on track/power/status as on, off, epo
      or unknown, from LocoNet's own power messages and the command station's slot 0 at startup.
    • "BDL 100" reads (never writes) a BDL716's options, as JMRI does, and publishes them as JSON
      on track/bdl/100/settings. "RAW BB 00 00 44" sends one read-type frame and logs what comes
      back, for diagnostics.
    • Removed: track/sensor/status, LOCONET_SENSOR_TOPIC, LOCONET_SENSOR_CMD_TOPIC and
      LOCONET_IGNORE_SENSORS (turnout-decoder feedback is simply not published).

v1.2.1

Choose a tag to compare

@ihancock ihancock released this 04 Oct 18:12

Full Changelog: v1.1.0...v1.2.1