You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
The main tabs are grouped into Setup, Results and Analysis. A header row
above the tabs holds a segmented group bar that shows the tabs of one group,
and the workspace switch on the right.
Settings > Interface > Appearance offers a light theme (the default), a dark theme, one
that follows the system, and the native platform controls. Status texts,
warnings and hints take their colours from the theme, so they stay readable
in the dark theme.
Sequence forms fold rarely changed rows into an "Advanced" section.
Live mode plays rectangular pulses of finite length that turn about the
effective field, including off-resonance and gradients. RF and gradient traces
follow the played fields, and 3D Vector shows the B1 arrow.
Parameter loops and spin probes show progress, elapsed and remaining time;
loops also show the current run.
The sequence source list is grouped by sequence type and opens Pulseq files
and Python scripts directly.
Calibrated receiver noise rescales a finished relative voxel sum result
instead of asking for a new run.
The focused input field is highlighted, and disabled controls and their
labels are greyed out.
docs/ui_module_split_plan.md plans splitting main_window.py and sequence_simulation_widget.py into topic modules.
The Sequence tab shows a gradient load plot: amplitude and slew rate per
axis against the scanner limits at the gamma of the imaged nucleus, with a
warning (display only, the sequence is not changed).
The birdcage coil offers 4, 6, 8, 12 or 16 rungs.
Settings > Interface > Appearance has an accent colour for the light theme.
Spin probes: "Open Result" opens a finished run in the Reconstruction
Explorer or the probe view, the ADC samples can be jumped to and scrolled
through, and the Signal view can show "ADC samples only".
The k-space view offers a dB scale.
Changed
Physical voxel-volume signal weighting is the default for 3D phantoms.
3D Vector keeps its plot settings behind "Plot options"; with live mode off a
single line replaces the disabled live controls.
The RF pulse designer shows the calculated time-bandwidth product and RF
bandwidth as "(auto)" rows.
Axes in ms, mm, ppm or mT/m keep their unit instead of gaining an SI prefix
such as "mms".
The "3D Magnetization Animation" view is called "3D Animation"; saved projects
still restore it.
Main tabs scroll instead of shortening their names, the Free Mode parameter
panel keeps its width when the window grows, and the first window scales with
the screen.
Sequence runs report progress every few seconds. The remaining time follows
the recent rate and grows when a report is overdue.
Generate sequence, live preview and Run build the sequence in a background
thread, so the window stays responsive while a long sequence is built and
analysed. Run waits for the sequence and can be cancelled meanwhile; settings
changed during a build start it again with the new values. The compiler
looks up the intervals of all events in one search, so a compiling worker no
longer starves the window.
The spin-grid recommendation for gradient spoilers reuses per-axis factors
across candidate grids, which makes it about 30 times faster with identical
results.
The sequence section is a compact form: Source, Nucleus with reference,
Time step with live preview, then Generate sequence next to Import and Export
menus. A status line says whether the sequence is up to date, being
generated, outdated by changed settings or failed, and links to the PSF
Analysis tab; it replaces the sequence summary table.
The RF bandwidth is the full width at half maximum of a simulated slice
profile. Slice-selection gradients follow the profile at the played flip
angle; analytic pulses whose slice gradient would exceed the scanner limit
are lengthened and the status line says so.
The setup viewer keeps its tab bar on the left.
PSF Analysis shows the full profiles, the spin probe buttons are always
enabled, and Free Mode shows the maximum per axis.
Fixed
A decimal point typed while only the integer part of a value is selected
replaces the old fraction, so "32.00 mm" can be changed to 64.30.
Starting long multi-repetition sequences no longer blocks the window for many
seconds; sequence duration queries took quadratic time.
The parameter loop progress bar no longer stays at "Saving loop result…".
On short screens the B1 Fields editor column scrolls instead of drawing the
field source rows on top of each other.