Skip to content

v3.3.0.0

Choose a tag to compare

@Duc-automation Duc-automation released this 22 Oct 12:55

MLAstroRPA v3.3.0.0

Auto polar alignment over the NINA message broker: the MLAstro controller becomes an alignment system of TPPA, and the operator keeps a confirmation dialog in front of every take-over.

Requires the MLAstro device firmware 1.2.0 or newer. The broker features need a TPPA build that contains the bridge (the current PR build).

Republished 2026-10-22: same plugin code, fresh build of 3.3.0.0 — the package now ships NINA.Plugins.PolarAlignment.dll 2.2.8.0, built from the TPPA master that contains the merged bridge work, so the MSI and the TPPA plugin are on the same version again. The MSI build also stages both dlls itself now, so the package can no longer carry a stale or Debug copy (see the previous republish note of 2026-10-14 for the three fixes that came in earlier).

✨ Highlights

  • Auto polar alignment over the broker: TPPA hands the correction over to the MLAstro controller, which drives the axes with its own strategy while TPPA keeps measuring (no computer at the telescope needed once the run is going).
  • The controller is chosen by the operator: it appears in TPPA's alignment system list and nothing is connected on its own; one controller owns a run, and later announcements can no longer take it over.
  • The controller and its hardware have to be ready before TPPA captures the three reference frames, and a run that never gets there ends with one clear error instead of frames that cannot be trusted.
  • "Auto pause TPPA after solved three point" (SOFTWARE SETTING, on by default): the run is held right before the first correction move and a toast says that RESUME starts the correction, so the measured result and the setup can be checked before the motors start; a result that is already inside the tolerance is finished by TPPA without any pause.
  • Taking the axes over asks first: the confirmation dialog shows the live controller state (STATUS, link, both axis angles in degrees), offers Stop the axes and continue / Skip, and closes itself when the travel ends by itself or its readiness window is over.
  • Switching the broker off says goodbye, so TPPA drops the controller from its list at once instead of after the timeout.

🔧 Fixed

  • A firmware link that is lost while TPPA is still measuring its three reference frames cancels the run instead of being ignored: the plugin remembers a link that came up inside the broker's connection ladder, so the first loss no longer makes the next one look like a link that never existed.
  • A firmware link that is lost after the axes were handed over ends the run with a fault instead of answering measurements from a dead link, so a pulled cable or a closed connection cancels the run instead of leaving it waiting until the operator stops it by hand.
  • A broker message that TPPA addresses to another controller is dropped, so two MLAstro builds (this plugin and a test build, each with its own GUID) can listen on the same topic while only the selected one drives its own hardware.
  • A pause that arrived while the controller was answering no longer leaves the run waiting for a resume only the controller could send.
  • Every measurement waits for its own answer, so the correction no longer captures on with the first answer of the run.
  • A run publishes its session id when it opens, so a controller no longer ignores the readiness of the new run.
  • Readiness reports the real state of the axes, so a travel that finished while the operator was deciding is handed over as ready at once.
  • A failed readiness gate reports a single error instead of two, and the Debug build no longer closes NINA.

⚠️ Notes

  • Windows 10/11 with NINA 3.x; install the MSI over the previous version, settings and profiles are kept.
  • Without the TPPA bridge build the plugin works exactly as before (manual control, assist, hardware settings); the automatic mode simply cannot be selected.
  • The MLAstro firmware link (COM or Wi-Fi) must be up before an automatic run starts; the dialog and the readiness check take care of the rest.
  • With the hold on, the correction waits for RESUME in TPPA; turn it off when a run has to correct without stopping.

📦 Assets

  • MLAstroRPA_Plugin_3.3.0.0.msi — installer for NINA (SHA256: 4ECA7B11494F4F7631D0311EA0394BA5590D0F6F4432CBB7C772109B87A1A7B0)
  • NINA.Plugins.MLAstroRPA.dll — manual update of the plugin dll (3.3.0.0)
  • NINA.Plugins.PolarAlignment.dll — the TPPA bridge dll that goes with this plugin (2.2.8.0)

Details: Changelog.md, section ## 3.3.0.0.