Flow Detail Views

Mikayla edited this page Oct 3, 2026 · 11 revisions

Flow Monitor Detail Windows

Table of Contents

  1. Detail View Overview
    1. Switcher Control
  2. Reactor Detail View
  3. Boiler Detail View
  4. Turbine Detail View

Detail View Overview

If enabled in the Coordinator UI configuration, Reactor, Boiler, and Turbine blocks on the flow monitor can be expanded into windows with full detail views of those components.

All boilers for a unit and all turbines for a unit are displayed together when you open boilers or turbines, so this can increase monitor height requirements if you have more than one boiler or turbine even if you only have one or two units.

Clicking any of the below blocks after this feature is enabled in the Coordinator's configurator will bring up the associated detail views.

image image image

Switcher Control

If enabled in configuration, a button window switcher control will be shown in the bottom right to help switch windows if you can't reach the whole screen.

image

Reactor Detail View

Most fields should be self-explanatory with their labeling. Some more specific fields will be described below.

The peak operating temperatures are computed based on the reactor's build running at the maximum possible burn rate of that build. This can help you determine if sodium cooling is required to keep the reactor below the critical temperature of 1200K, or if you cannot run at the maximum burn rate. This value is only accurate if your Mekanism configuration matches that entered on the Supervisor. These values are used for some high temperature warnings.

The simulation technical details pressures and flow rates are estimated values with a lot of assumptions mapping Mekanism to real-world reactors, purely there for some immersion.

image

Boiler Detail View

Most fields should be self-explanatory with their labeling. Some more specific fields will be described below.

The feedwater minimum is the minimum supply of water this boiler needs to maintain the current temperature without runaway to keep up with the reactor. This likely will be higher than the water return rate during turbine ramp up, at which point you should have auxiliary coolant provide extra water.

The simulation technical details pressures and flow rates are estimated values with a lot of assumptions mapping Mekanism to real-world reactors, purely there for some immersion.

image

Turbine Detail View

Most fields should be self-explanatory with their labeling. Some more specific fields will be described below.

The response tau values indicate the time delay of the turbine at its current (or max) flow rate to changes in the flow rate. Turbines with low response tau values respond faster to changes in flow rate, meaning that during ramp up they can supply water faster to the reactor or boiler. However, this requires high vent to volume ratios, which means less turbine rotor and less efficient energy generation.

The efficiency and energy multiplier indicate how much power you're getting out of your steam flow. Some versions of Mekanism will not meet 100% due to some rounding in the values returned to ComputerCraft. 99.99% and 9.9988 respectively should be considered the same as 100% and 10 in that case. For the most energy efficient setup, you'll need a 14 high rotor with 28 blades.

The simulation technical details pressures and flow rates are estimated values with a lot of assumptions mapping Mekanism to real-world reactors, purely there for some immersion.

image

Homepage

  1. User Manual
    1. System Setup Guide
      1. Device Layout
        1. Coordinator Displays
      2. Connecting to Mekanism Machines
      3. Application Installation
        1. Space Requirements
        2. Installation
        3. Updating
        4. Uninstalling
      4. SCADA Network
        1. Network Channels
        2. Network Connectivity
      5. Setup & Configuration
        1. Supervisor Setup
        2. Coordinator Setup
        3. Reactor PLC Setup
        4. RTU Gateway Setup
      6. Initial Startup
    2. Configurator Tools
      1. Supervisor Configurator
      2. Coordinator Configurator
      3. Reactor PLC Configurator
      4. RTU Gateway Configurator
      5. Pocket Configurator
    3. Redstone Waste Setup Guide
    4. TL;DR Quickstart
    5. FAQ and Common Problems
    6. Colorblind Accessibility
    7. Annunciator Panels
    8. Alarms
    9. System Views
      1. Main View Screen
      2. Valve & Flow Screen
        1. Flow Detail Views
      3. Unit View Screens
    10. Operating Procedure
    11. Status Messages
    12. Glossary
  2. Computer Applications
    1. Reactor PLC
      1. Front Panel
      2. Non-Networked Mode
      3. RPS
      4. PLC Emergency Coolant
    2. RTU Gateway
      1. Front Panel
    3. Supervisory Computer
      1. Front Panel
    4. Coordinator Computer
      1. Front Panel
    5. Pocket
      1. Home and Navigation
      2. Connectivity
      3. Main Applications
      4. System Details and Testing
  3. Notable System Components
    1. Co-routine Threading
    2. Project File Layout/Overview
    3. PPM - Protected Peripherals Manager
    4. RSIO - Redstone I/O
    5. Networking
  4. Notes
    1. Known Issues
    2. Process Closed Loop Controller
    3. Project Files and Layout
    4. Alternative Installation Strategies
    5. Running on a Monitor
  5. Investigations
    1. Startup Rate High
    2. Reactor Temperature Calculation
  6. References & Resources
    1. CC: Tweaked Character Set
    2. Mekanism API Notes
    3. Design & Regulatory References
  7. Legacy
    1. coord.settings File
    2. config.lua Files
      1. Supervisor config.lua
      2. Coordinator config.lua
      3. Reactor PLC config.lua
      4. RTU Gateway config.lua

Clone this wiki locally