Skip to content

Releases

Logi Center v0.5.1 — Qt6/QML

Choose a tag to compare

@Mirox921 Mirox921 released this 29 Oct 16:03

Logi Center v0.5.1 — Qt6/QML

29 October 2026

Logi Center now launches Qt6/QML by default and ships a single QML interface.
The GTK presentation is removed from the current application; the public v0.4.0
release remains in Git history and the exact pre-cutover baseline is retained
in a separately verified local backup. Shared device services, adapters, drafts and backup formats are retained.

The v0.5.0 candidate was not published as a release: CI uncovered a legacy
Dashboard QA callback incompatibility. v0.5.1 corrects that fixture, adds a
regression test, and declares Cairo/headless Qt CI dependencies. The existing
v0.5.0 tag is retained; published tags/history are not rewritten.

Highlights

  • Graphite/amber Dashboard, responsive device editors and native QML backups.
  • G502 HERO supplied SVGs shared across Dashboard and top/side button views;
    all 11 native IDs retained, clearer hover/selection overlays and profile-state
    handling. Native static/off/cycle/breathing parameters are capability-driven.
  • Separate macro capture window and private reusable library; input is consumed
    locally while recording so Space and clicks do not activate other UI controls.
  • Expanded K7 Ultra DPI/button/sensor/dock panels and Ace68-II keyboard editors,
    preserving model/firmware restrictions, RMW masks and readback guards.
  • G515 scoped Solaar settings, RGB/per-key editors and availability correction:
    disabled RGB ownership does not make the whole device unavailable.
  • Model-verified EWEADN S9 protocol adapter and supplied vector artwork;
    native macro-bank upload remains blocked without a safe read/rollback path.
  • Audio endpoints, microphone controls/tests, EasyEffects import/presets,
    diagnostics, selective restore and private safety snapshots use shared services.
  • RU/EN, reduced motion and persistent QML scale 75–200% after restart.
  • English live Wayland screenshots and a lean repository/source archive.
    2241 generated historical screenshots no longer occupy the current Git tree;
    history, local archives and the four real test fixtures are preserved.

Hardware evidence and limitations

The user physically confirmed G502 LED 1 Color Cycle, period 8000 ms,
brightness 255: continuous animation persists after closing Logi Center.
This does not certify breathing, all zones/speeds, reboot persistence or G HUB parity.

K7/Ace68 selected reversible tests and dock observations retain their exact
scope in device reports. New native sensor/key-bank paths are not all physically
verified. During the recent live read-only check, the K7 receiver was present
but returned an empty mouse identity reply; the editor now reports this state
with a wake/retry hint instead of hiding the error. No reset or profile recovery
is performed automatically.

S9 is protocol/mock-tested without a physical S9 in this environment. G515
availability is regression-tested, but the current machine lacks that keyboard.
No universal model/firmware certification is claimed. ckb-next remains detection-only;
unknown/unsupported features stay disabled. See backend support
and action-level verification.

Install or upgrade

The release source is not a bundled AppImage. Install Python, PyYAML, PyGObject
(for shared Gio/GLib D-Bus readers), PySide6, Qt Quick/Controls and SVG;
Wayland additionally needs its Qt platform plugin. GTK4/libadwaita are no longer
application dependencies. Optional hardware backends are installed separately.

From the extracted source:

python app.py --version
python app.py
python install.py

Rerun python install.py after updating source if you launch from the
application menu: that launcher uses the installed copy, not your checkout.
Preferences, drafts, artwork and private backup files are preserved.
--ui qml remains compatible; --ui gtk directs you to the archived baseline.

The attached Arch package is built locally; clean-machine installation and
all optional-backend combinations are not certified. It was not installed into
this system during release preparation. Verify attached files with SHA256SUMS.

Verification

See release validation for exact tests, packaging,
screenshot capture and hardware boundaries. Mock writes are not physical tests.
No physical settings or microphone recordings were changed to prepare this release.

Release assets: source archive, Arch package, PKGBUILD and SHA256SUMS. Runtime/archive/metadata checks and packaged QML startup were performed without physical setting writes.

Full GitHub Actions verification passed for this release commit: https://github.com/Mirox921/logi-center/actions/runs/40906414384

Logi Center v0.4.0 — Universal Linux Peripheral Manager

Choose a tag to compare

@Mirox921 Mirox921 released this 24 Oct 11:42

Logi Center v0.4.0

Stable release · 24 October 2026

Logi Center now presents itself as a Linux peripheral manager rather than a Logitech-only control panel. It uses multiple existing Linux backends and displays only the capabilities those providers report. This is a meaningful expansion, not a claim of universal device support.

Highlights

  • MCHOSE K7 Ultra mouse and MCHOSE Ace68-II keyboard have separate, revision-scoped adapters and appear in the correct device categories.
  • Physical read/write/readback checks were completed for the documented K7 DPI setting and the Ace68-II settings listed in the hardware report. Tested original values were restored.
  • Logitech G502 HERO keeps its existing libratbag controls; physical discovery, five profiles, eleven buttons, two lighting zones and backup preview were checked read-only.
  • Common capability-based mouse and keyboard pages combine available provider features. Device inventory cards collapse, search by name and retain device-specific state.
  • Battery values preserve provenance, charging state and unknown/error conditions instead of inventing a percentage.
  • Optional OpenRGB, OpenRazer, rivalcfg and ckb-next providers join existing libratbag, Solaar, HeadsetControl, PipeWire/PulseAudio and Linux input support.
  • Versioned capability backups include previews, selective restore and partial-operation reporting; diagnostic exports are explicit and redacted.
  • English/Russian UI, mock scenarios, GTK smoke checks and local Arch packaging documentation are included.

Device validation

Only the exact attached units named here were physically tested:

  • MCHOSE K7 Ultra, USB 3837:1001: configuration and battery reads; reversible DPI change 400 → 450 → 400 with fresh device readback.
  • MCHOSE Ace68-II, USB 41e4:2116, firmware code 121: reversible readback checks for profile, polling, lighting, brightness, effects, selected-key actuation, Rapid Trigger and dead zones; selective backup/restore.
  • Logitech G502 HERO, USB 046d:c08b: physical read-only inventory and backup validation. Setting writes/visible RGB are not claimed as physically verified.

These checks do not certify other revisions or models. Full-profile firmware images are not backed up. Ace68-II SOCD/Snap Tap, DKS, Mod Tap, Toggle Key, remapping, macros and per-key RGB editing remain unavailable. See backend support for provider-by-provider boundaries.

Testing and packaging

The release source is checked with the repository's unittest, syntax/consistency, GTK smoke and isolated simulation workflows. Automated tests use mocks and do not count as hardware validation. A clean Arch installation and every optional-backend/device combination are not certified by this release.

Build a local Arch package from source using these instructions. The build helper does not install the package, change permissions or enable udev rules.

Upgrade

From a source checkout, pull the v0.4.0 tag and rerun python install.py. Existing per-user preferences, drafts and backups are kept. If changing between a per-user install and a system package, choose one launcher intentionally; see the Arch packaging notes.

Downloads and stars

GitHub updates the README badges with current repository stars and release-asset download counts. The count is for attached release assets; GitHub's automatically generated source archives are not included in that download counter.

Logi Center v0.3.0 — Reliability, backups and visual mouse editor

Choose a tag to compare

@Mirox921 Mirox921 released this 23 Oct 14:25

Logi Center v0.3.0 — Reliability, backups and visual mouse editor

A substantial public preview update to the existing Linux control panel for Logitech G305, G502 HERO, G515 LIGHTSPEED TKL and wired G PRO X. This is a pre-release: automated and read-only checks pass, while hardware writes, restores, reconnects and voice capture still need broader physical validation.

1. Honest application results

  • A shared operation model distinguishes confirmed, sent without confirmation, mismatch, error, disconnected and cancelled.
  • Supported parameter-specific getters compare requested and observed values, including audio volume tolerance. Mismatches show both values.
  • libratbag's G502 profile/RGB properties are explicitly labelled backend cache. A matching cache value is never presented as proof of the visible LED color.
  • Unsupported readback, transport failures, deadlines and cancellation receive explicit results. Sidetone and unsupported keyboard RGB getters are not invented.

2. Device backup and guarded restoration

  • Export supported profiles, DPI stages, polling rate, button actions/macros, lighting and supported audio/keyboard fields as versioned JSON with model identifiers, creation date, provenance and SHA-256.
  • Validate structure, integrity, model compatibility and allowlisted actions before restoring. A checksum detects corruption; it is not a signature.
  • Preview changes, select categories, save a private pre-restore snapshot and stop on the first mismatch/failure. Stale previews are rejected; partial results include individual outcomes.
  • These are supported backend-field backups, not firmware images. Mouse values may be cached; G515 data is saved Solaar configuration. Unsupported independent channel-volume restoration is skipped. There is no speculative automatic rollback over a failed connection.

3. Connection and lifecycle handling

  • udev and PulseAudio events trigger debounced refreshes; optional pyudev has a five-second sysfs fallback.
  • Disconnected controls are disabled, old operations cancelled and late results discarded. Selection, tab and scroll position are preserved where possible.
  • Fixed stale “Connected via USB” for an unplugged G502: the remembered model is separate from connection state. Backend failures mean unknown connectivity; an empty device list means offline.
  • Explicit executor/subscription shutdown and bounded radio-keyboard polling.

4. Redesigned visual mouse editor

  • Separate vector silhouettes for angular G502 HERO and rounded wireless G305, with a generic fallback for other layouts.
  • Numbered controls, selected-only guide line, highlighted selection and direct selection on the illustration. The diagram does not claim to show live RGB.
  • Current assignment, predefined actions, explicit keyboard recording, macro event/delay editing, validation, desktop-shortcut warnings and draft reset. Macro writing is enabled only when ratbag reports the capability.
  • Existing assignment controls remain available.
  • Fixed standard clicks incorrectly selecting “Custom macro”; both interfaces now share typed matching for clicks, special actions, keys and known macros.

G502 and G305 vector illustrations

These are renderer previews with example selection, not screenshots of connected G305 hardware or live RGB readings.

5. Microphone and headphone workflows

  • Separate input/output preset lists and independently saved selections. Managed direction-specific EasyEffects names prevent same-name presets loading both pipelines.
  • An explicitly started microphone level meter, short recording (up to eight seconds), playback and deletion.
  • Original/processed clips are offered only when an actual EasyEffects capture route from the selected microphone is detected; otherwise only the original is recorded. Streams may have different latency.
  • No recording on startup. Clips are temporary and removed on refresh, disconnect, deletion or exit.
  • Missing microphones/backends, access failures and playback errors are surfaced. Cancelled preparation cannot start a delayed recording.

6. Diagnostics and development

  • A diagnostics window distinguishes missing/unavailable components, access permissions, unsupported device/backend operations, disconnects, communication errors, configuration and internal faults, with recovery suggestions.
  • Bounded private rotating logs redact sensitive identifiers and omit assignment/macro values; backup/log files use private permissions.
  • Business logic, execution, discovery, backup, audio and drawing modules are separated from GTK integration; writes are serialized outside the UI thread.
  • Russian/English UI coverage, reusable check/diagnostic/GUI scripts, CI syntax checks, project instructions and implementation progress documentation.

Validation

  • 69 automated tests pass, covering verification/mismatch/unavailable readback, cancellation/timeouts, mock reconnects, corrupt/incompatible backups, partial restore, missing backends/microphones, preset isolation, privacy and parsing regressions.
  • Syntax compilation and whitespace checks pass. Independent GTK smoke covers widgets, language, dialogs, cancelled recording preparation and the unplugged-header regression, without device writes or microphone capture.
  • Connected G502 read-only inspection validated five profiles and JSON export/read/unchanged-preview. Audio-server snapshots validated.
  • Not physically verified in this cycle: writing G502 RGB/DPI/buttons/macros, hardware restore, rapid physical reconnects, G305/G515 behavior, real voice recording/playback or reboot persistence. No optical RGB measurement is available.

Install or update

Install the documented dependencies, download logi-center-0.3.0.tar.gz, extract it, and run:

python install.py

Close an already open Logi Center window before reopening the updated app. The per-user installer retains existing preferences; it does not change system permissions or udev rules. Optional python-pyudev enables udev monitoring; parec and paplay provide test capture/playback. Arch Linux/Wayland was used for desktop checks; other distributions remain unverified.

Verify the attached archive beside SHA256SUMS:

sha256sum -c SHA256SUMS

GitHub's automatic source archives are separate and are not covered by this checksum file. Full implementation details: reliability report. This is an independent community project, without original Blue VO!CE/DTS, firmware updates or a full G HUB replacement.

По-русски

Новая предварительная версия включает все шесть направлений улучшений:

  • Честные статусы применения: подтверждено, отправлено без подтверждения, несовпадение, ошибка, отключение и отмена. Кэш G502 не выдаётся за фактический цвет подсветки.
  • JSON-копии с проверкой целостности/модели, предпросмотром, выбором категорий, защитной копией и отчётом о частичном восстановлении. Это не полная копия памяти устройства.
  • Автообнаружение подключений, отмена устаревших операций и исправление ложного USB-статуса после отключения G502.
  • Новые силуэты G502/G305, интерактивный выбор кнопок, запись клавиш, поддерживаемые макросы и отмена черновика. Исправлено ошибочное «Собственный макрос» вместо ЛКМ/ПКМ.
  • Раздельные пресеты микрофона/наушников, индикатор уровня, запись до восьми секунд и прослушивание реально доступных трактов. Запуск — только кнопкой; образцы временные.
  • Диагностика компонентов, понятные ошибки, приватные журналы и архитектурное разделение модулей.

69 тестов проходят, проверка GTK выполнена без аппаратных записей и захвата голоса. Физическое применение настроек, восстановление, переподключение, запись/воспроизведение микрофона и перезагрузка ещё требуют проверки; G305/G515 во время разработки отсутствовали. Поэтому релиз помечен Pre-release.

Для установки/обновления скачай архив logi-center-0.3.0.tar.gz, распакуй и выполни python install.py, затем перезапусти приложение. Существующие предпочтения сохраняются. Подробные ограничения и проверки перечислены в отчёте выше.

Logi Center v0.2.0 — G502 HERO support

Choose a tag to compare

@Mirox921 Mirox921 released this 23 Oct 13:05

Logi Center v0.2.0 — G502 HERO support

Updated public preview with the current application and screenshots.

New in this version

  • G502 HERO support alongside G305: 5 onboard profiles, 11 buttons and 2 lighting zones.
  • Active-profile DPI and polling-rate readout; inactive profile settings no longer appear as current values.
  • Profile and DPI-stage selection, additional button actions, and visual lighting mode/color selection.
  • Wired G502 is identified as USB-connected without a battery indicator.
  • Mouse profile and lighting screenshots, plus updated English/Russian documentation.
  • Improved audio layout: device names remain readable in narrower windows.

G502 readout was checked on connected hardware. Saved profile colors may differ from the visible lighting. Writing lighting, button mappings and profiles still needs broader physical testing.

Download and install

This is a source release for Linux. Install the dependencies listed in the README, then download and extract logi-center-0.2.0.tar.gz. Open a terminal in the extracted directory and run:

python install.py

The installer updates the application for your current user. Open Logi Center from the application menu. Existing preferences are retained. Tested on Arch Linux/Wayland; other distributions are not yet verified.

To verify the attached source archive, place it beside SHA256SUMS and run:

sha256sum -c SHA256SUMS

GitHub's automatically generated source downloads are separate archives and are not covered by this checksum file.

Checks and limitations

All 16 unit tests pass. The application was opened with a connected G502 HERO, its profile readout was checked, and the initial read-only inspection left the device settings unchanged.

This remains an early preview, not an official Logitech app or full G HUB replacement. Original Blue VO!CE/DTS, firmware updates, automatic game profiles and built-in advanced editors are not included. G515 lighting writes and G PRO X sidetone need further testing. See the README for first-time Solaar setup and known limitations.

Screenshots

G502 HERO profiles and DPI

G502 lighting and extra buttons

По-русски

Обновлённая версия с поддержкой G502 HERO: 5 профилей, 11 кнопок, две зоны подсветки и исправленное чтение DPI активного профиля. Скачай logi-center-0.2.0.tar.gz, распакуй и выполни python install.py. Программа обновится, пользовательские настройки сохранятся. Это предварительный релиз; ограничения описаны в README.

Logi Center v0.1.0 — First public preview

Choose a tag to compare

@Mirox921 Mirox921 released this 23 Oct 12:43

Logi Center v0.1.0 — first public preview

Common Logitech controls in one Linux desktop window, with English and Russian interfaces.

Included

  • G305 mouse DPI, polling rate and common button assignments.
  • G515 LIGHTSPEED TKL brightness, visual color selection, lighting effects and idle timers.
  • Wireless battery indicators, without inventing exact percentages for coarse readings.
  • Wired G PRO X USB audio output/microphone volume and sidetone controls when supported.
  • EasyEffects preset selection, JSON import, effects bypass and a community preset link.
  • Per-user installer, bilingual documentation and screenshots.

Install

This is a source release, not a standalone binary. It has been tested on Arch Linux with Wayland. Install the backend dependencies listed in the README, download and extract logi-center-0.1.0.tar.gz, enter its directory and run:

python install.py

Open Logi Center from your application menu. SHA256SUMS verifies the attached source archive; GitHub's automatically generated source archives are separate files.

Preview limitations

This is an independent community app, not an official Logitech product or a full G HUB replacement. Original Blue VO!CE/DTS processing, firmware updates and automatic per-game profiles are not included. Advanced editing opens the existing backend apps. G515 lighting writes and G PRO X sidetone need additional physical testing across firmware versions. Initialize new G515 settings in Solaar first. Other distributions and hardware models are not yet verified.

Validation

Fourteen unit tests pass, including translation coverage, saved preferences, preset import, battery parsing and read-only keyboard connection checks. The English/Russian language switch was checked in a running GTK window. Hardware interaction coverage is still limited; please report issues with your device model, connection type, distro and backend versions, with private identifiers removed.

Screenshots

Headset volume and microphone ·
Saved keyboard lighting (device offline) · Audio effects