Skip to content

Releases

v4.0

Choose a tag to compare

@Gingerman1996 Gingerman1996 released this 24 Aug 06:45

Release date: 2026-01-26

Summary

This release updates the power/charging architecture to support charging from both USB-C and a solar cell by migrating the charger IC from BQ25672 to BQ25798, and improves inrush/current ramp behavior by adding an RC soft-start network to the load switch.

Major changes

1) Charger IC migration: BQ25672 → BQ25798

Replaced BQ25672 with BQ25798 to support charging from USB-C and Solar Cell.

Chip identification check (REG48 – Device Part Number):

  • 011b = BQ25798
  • 100b = BQ25672

Electrical / Functional impact

  • Charging source support expanded: USB-C + Solar (via BQ25798 capability).
  • Firmware/bring-up should verify the correct charger is populated by reading REG48 on first power-up.

Dual input source monitoring:

  • BQ25798 supports 2 power input sources with voltage monitoring capability:
    • VAC1 (REG37_VAC1_ADC): monitors Solar Cell input voltage
    • VAC2 (REG39_VAC2_ADC): monitors VUSB input voltage
  • Firmware can read voltage from each source independently via I2C registers (see datasheet Section 9.5.1.48 and 9.5.1.49).

VBAT reading behavior without battery:

  • If battery is not connected or BMS disconnects the battery, VBAT ADC reading (REG3B_VBAT_ADC) may show ~12.6V or fluctuate/become unstable while charging is still enabled.
  • This is expected behavior when no load/battery is present on VBAT pin.
  • BMS will also disconnect charging if temperature is outside the allowed charging range (too high or too low).
  • Firmware should detect this condition and handle accordingly (e.g., disable charging, flag error state).

Manufacturing / Assembly notes

  • Ensure correct charger IC (BQ25798) placement and orientation.
  • Update BOM and AVL to reflect the new charger IC and any supporting passive changes required by the new part.

2) Load switch soft-start improvement

Added RC network on the load switch control to implement soft-start, reducing inrush current and improving power ramp behavior.

  • RC soft-start network: added to load switch control pin to reduce inrush current (Iinrush) from the load switch chip during turn-on.
  • Soft-start prevents excessive inrush current that could trigger voltage droops or stress upstream power sources.
  • Verify RC values and placement against schematic/PCB during assembly review.

3) Brownout protection capacitor

Added 470µF bulk capacitor before the load switch input to improve power supply stability.

  • 470µF capacitor: placed at load switch input to prevent brownout during power-up transients and provide stable supply during load switching events.
  • Improves system stability and brownout immunity.
  • Verify capacitor value, voltage rating, and placement during assembly review.

4) Solar cell input capacitor voltage rating upgrade

Upgraded voltage rating of capacitors at solar cell input to prevent component damage from overvoltage conditions.

  • Capacitor voltage rating increased: capacitors at VSOLAR input now have higher voltage ratings to withstand potential overvoltage from solar cell under various lighting/temperature conditions.
  • Prevents component damage and improves long-term reliability of solar charging circuit.
  • Verify updated capacitor specifications (voltage rating, capacitance, package) in BOM and during assembly review.

Validation checklist (recommended)

  • Charger detection: confirm REG48 reads 011b on v4.0 boards.
  • USB-C charging: functional charge test across expected input range.
  • Solar charging: functional charge test with solar input profile / bench-simulated solar source.
  • Load switch ramp: scope switch node/rail ramp-up; confirm reduced inrush and stable startup.