Skip to content

winunitd 0.6.0

Choose a tag to compare

@github-actions github-actions released this 18 Nov 02:49
· 5 commits to main since this release
Immutable release. Only release title and notes can be modified.
28c8701

winunitd 0.6.0

A User= system unit can now start with its account's signed-in session
instead of an S4U logon, so a unit of a domain account keeps working away from
the domain network while that account is signed in. For Windows 11 Enterprise
and Enterprise LTSC x64; no Go or .NET runtime is needed on the destination.

The MSI is not code-signed yet, so Windows SmartScreen may warn when you open
it. Check the download against this release's SHA256SUMS and build provenance:

Get-FileHash .\winunitd-0.6.0-x64.msi -Algorithm SHA256
gh attestation verify .\winunitd-0.6.0-x64.msi --repo PLN/winunitd `
  --signer-workflow PLN/winunitd/.github/workflows/release.yml `
  --source-ref refs/tags/v0.6.0

Install or upgrade

From an elevated terminal:

msiexec /i .\winunitd-0.6.0-x64.msi /qb

Over 0.5.1, 0.5.0, 0.4.0 or 0.3.0 this upgrades in place: the service stops,
the new version starts, and units, enablement, logs and linger grants carry
over. See the
installation guide
for installation and earlier package upgrades.

New since 0.5.1

  • UserLogon= on User= system units. A User= unit is logged on by S4U
    at every start, and S4U of a domain account needs a domain controller. On a
    machine away from its domain network, with the account signed in from
    cached credentials, such a unit could not start, restart or be upgraded.
    [Service] UserLogon=session-or-s4u beside User= makes each start use a
    copy of the token of a session the account is signed in to, active or
    disconnected, and S4U only when there is none or its token cannot be used:

    [Service]
    ExecStart=C:\Apps\worker.exe
    User=S-1-5-21-1-2-3-1001
    UserLogon=session-or-s4u
    Restart=always
    RestartSec=2s

    Sessions are matched by the SID in their token, never by name, and another
    user's session is never used. The process still runs in session 0, on the
    private desktop and in its unit job, with nothing visible in the user's
    session; an administrator under UAC gets the full linked token, never the
    filtered one.

    A session logon has what S4U lacks: Windows credentials for other machines,
    DPAPI, Credential Manager and EFS, and the INTERACTIVE group in place of
    NETWORK or BATCH. Whether a start gets one or the other depends on the moment it
    starts, so a unit must not depend on the difference.

    When the session whose logon an invocation uses signs out, the manager stops
    that invocation (with ExecStop) and records
    session <N>, whose logon this invocation used, signed out. Windows does not
    end these processes itself. The stop counts as a failed exit, so
    Restart=on-failure and always start the unit again, by S4U or another
    session. ExecStop of such an invocation runs on the invocation's own logon,
    also at sign-out and off the domain network. Lock, unlock, disconnect,
    reconnect and other users' sessions do nothing to the unit. Status shows the logon in use as Logon: s4u or
    Logon: session 2 (userLogon and userSession in the JSON), the journal
    records each start's logon, and capabilities list unit-user-session on the
    system endpoint.

    The default is unchanged: s4u, the same as leaving the directive out, so
    existing units behave as before. verify and reload reject UserLogon=
    without a User= naming an account other than SYSTEM, and in format 1 files,
    user units and proxies
    (session logon,
    design).

Fixes since 0.5.1

  • A workload that exits with code 259, the value Windows uses for a process
    still running, is now seen as exited with status 259. The manager could
    previously wait on it indefinitely and block cleanup. User-manager liveness
    checks also use the process handle's state.
  • A notify connection is accepted only once the unit's main process is
    assigned, and only from that process or a process in its job; anything else
    is refused.
  • Each WantedBy= entry must be a single name. Path separators, drive or
    stream colons, control characters and other characters invalid in Windows
    file names are rejected by verify and reload, and enable checks every
    name before it writes any link.
  • Workload journal files get a protected Windows ACL that allows only the
    manager's account, SYSTEM and Administrators. Rotated archives keep it, and
    existing files are repaired when the unit's journal opens; journals of units
    that never open again keep their previous ACL until retention removes them,
    and grants added to journal files by hand are replaced.
    SECURITY.md now
    describes the lifecycle metadata visible to readers of the shared Windows
    Application event log.
  • Built with Go 1.27.4, which fixes
    GO-2026-6809 (crypto/x509) and
    GO-2026-6859 (net/http) in the
    Go 1.27.2 that built 0.5.1.

Limits

  • UserLogon=: an invocation keeps the logon it started with, so a unit
    started by S4U is not moved to a session when its account signs in; its next
    start uses the session. A User= written as DOMAIN\name is still resolved
    before every start, which may ask a domain controller; write the SID to avoid
    that. A sign-out is missed only if its notification is dropped and Windows
    reuses the session ID within one poll interval; the invocation then keeps its
    logon until its next restart, as user managers do. At machine shutdown,
    users sign out before the service stops, so such a unit may get a sign-out
    stop and one S4U start before the ordered stop.
  • Otherwise support and limitations remain as documented for
    0.5.0.
    Signing remains deferred.

Qualification

Hosted CI ran the unit, race and integration tests on Windows and Linux. For
UserLogon= they cover the directive's rules, the capability, session order
and SID matching over a fake native layer, the full-token rule, the fallback
and its errors, status, the stop at sign-out with Restart=, a sign-out during
a start, and the logoff hook. The tests that need LocalSystem and a signed-in
test account do not run in hosted CI.

This MSI also ran natively on a Windows 11 domain member with its domain
controller switched off and the unit's account signed in from cached
credentials: start and five restarts on the session logon, ExecStop as the
account, a sign-out right after the controller went away (the unit stops,
waits in auto-restart and starts again at the next sign-in, without a reboot),
the restart by S4U after a sign-out with the controller on, and the three
LocalSystem tests. The unchanged default, the both-fail error, a cold boot with
automatic sign-in, the administrator token under UAC and lock and disconnect
ran on the first 0.6.0 candidate, which differs only in how ExecStop logs on.
The run will be recorded in docs/R4-EVIDENCE.md on main.