Repository navigation
winunitd 0.6.1
This patch fixes ExecStop during manager shutdown and adds a preflight
check for upgrades from affected releases. For Windows 11 Enterprise and
Enterprise LTSC x64; no Go or .NET runtime is needed on the destination.
The MSI is not code-signed yet, so Windows SmartScreen may warn when you open
it. Check the download against this release's SHA256SUMS and build provenance:
Get-FileHash .\winunitd-0.6.1-x64.msi -Algorithm SHA256
gh attestation verify .\winunitd-0.6.1-x64.msi --repo PLN/winunitd `
--signer-workflow PLN/winunitd/.github/workflows/release.yml `
--source-ref refs/tags/v0.6.1Install or upgrade
From an elevated terminal:
msiexec /i .\winunitd-0.6.1-x64.msi /qbOver 0.6.0, 0.5.1, 0.5.0, 0.4.0 or 0.3.0 this upgrades in place: the service
stops, the new version starts, and units, enablement, logs and linger grants
carry over. The installed manager performs that stop. The incoming MSI checks
for affected system units before it starts maintenance. A preflight conflict
leaves the current manager and workloads running. For a planned upgrade, drain
units that need ExecStop= first as the
installation guide
describes.
Fixes since 0.6.0
- Shutdown runs
ExecStopfor active invocations. The maintenance quiesce
that servicing uses, and the service stop, seal the manager against new
starts and then stop every unit. Releases 0.3.0 to 0.6.0 also
refused theExecStophelper of that stop pass. An active unit with
ExecStop=then lost its processes withoutExecStop, the quiesce did not
reportquiesced, and the MSI failed with 1603 and rolled back. Rollback
restarts the previous manager, so the version stayed the same and the
running units had been terminated. After the seal, only the shutdown pass
can launch a fresh stop helper.
Limits
- Managers up to 0.6.0 keep this defect until they are replaced, also for the
upgrade to 0.6.1, a repair or uninstall of those versions, and a service
stop or machine shutdown. Units withoutExecStop=and inactive units are
not affected. - Otherwise support and limitations remain as documented for
0.6.0.
Signing remains deferred.
Qualification
The manager regression test shuts down with an active ExecStop= unit,
checks that its helper ran, and verifies that the workload and helper both
exited. Separate checks cover external helper requests after the seal and
late helper requests during final cleanup.
The released Windows MSI was tested with an enabled notify service and its required simple service, both using cooperative stop commands. The first upgrade attempt from 0.5.0 identified both active services and preserved the manager and workload process IDs. After an orderly drain, the direct upgrade to 0.6.1 succeeded. A repeat install on active 0.6.1 ran each invocation's stop helper once and recovered both workloads. Both services also recovered after a cold boot. Clean install and active uninstall passed on the same MSI.