Repository navigation
FulgurStack 0.15 (alpha, Windows x64)
Pre-releaseFulgurStack 0.15 (alpha, Windows x64)
Portable ZIP, no installer: unpack and run fulgurstack-gui.exe. The executables are not code-signed, so SmartScreen may ask for confirmation on first start. Tested on Windows 11 x64 only. See CTI_ME.txt in the package (Czech) for installation, requirements and quick start.
The package now holds two executables: blind plate solving is part of fulgurstack.exe (solve, solve-index), and the separate fulgur-solve.exe of 0.14 is gone.
Changes since 0.14
Stacking and output
- The coverage and high-rejection maps carry the same plate solution (WCS) as the master, in FITS and XISF, so they line up with the master in PixInsight.
- The master and both maps carry the median capture time of the stacked frames as DATE-OBS and DATE-AVG, instead of the start time of the reference frame.
- Stars clipped by a sensor below 16 bits (12-bit Dwarf3, 14-bit DSLRs) no longer enter the brightness scale; masters from 16-bit cameras are unchanged.
- The application and the command line make masters through the same code after registration.
Results
- Zooming into an XISF master, coverage map or high-rejection map shows sharp native pixels instead of the enlarged overview.
- When the full-resolution detail cannot be read, a red banner says so.
Application
- A light set set to None calibration stays uncalibrated after rescans, new calibration sets and restarts.
- Opening files with the program no longer replaces the saved light sets.
- Closing the application warns about an index build or master in progress.
- Background tasks (Gaia check, target look-up, index test and build, Auto-solve) no longer stay running after an internal error.
- A file that cannot be opened is named in the error.
Command line
- Blind plate solving moved into the main program:
fulgurstack solve-index build|infoandfulgurstack solve. - With
--input-sets,--exposuretakes one value per light set.
Fixes
- A damaged blind-solving index or XISF file is refused instead of ending the program.
- Calibration masters from many frames stay within about 2 GB of memory.
- A cancel during geometric correction stops sooner.
Checks on this package
Release test suites passed (default features 363, all features with GPU and SIMD 367); no Visual C++ runtime DLL imports; DS-B (27 of 32 frames) master, coverage and high-rejection maps byte-identical to the standard build; the application starts from the package folder.
SHA-256
c129b389dc342b4e174f835af07ab40a1b074eba680969e7ab0c7bbe906af33f FulgurStack-0.15.0-3736674-windows-x64.zip
d7b1b1cba9df0498c680df4090b1908fb181e0eccd94621219a41edc1a430a2d fulgurstack-gui.exe
f238e27e31047a567356a5fb8b8c07ecb01de27a839e21a26c38f7d4848ade78 fulgurstack.exe