Skip to content

MONAI-Physio 2026.11.2

Latest

Choose a tag to compare

@aylward aylward released this 18 Nov 05:11
b434932

Highlights

  • GPU blood-flow solvers. New WarpNavierStokes (P2/P1 incompressible
    Navier-Stokes with RCR Windkessel outlets, backflow stabilization and a cuDSS
    Schur-complement preconditioner, in float32 or float64) and
    WarpHyperelasticWall / WarpFluidStructure (prestressed Neo-Hookean wall
    with Dirichlet-Neumann coupling accelerated by IQN-ILS/Anderson).
    VisualizeFlowFields gives an interactive viewer and offscreen movie export.
  • Aorta blood-flow experiments rebuilt as short prepare/run/view/test
    scripts (1D rigid, 3D rigid, 3D two-way fluid-structure interaction). The
    fluid-structure experiment reaches a 117/78 mmHg root pressure in about an
    hour instead of 11.6 hours.
  • Per-label tetrahedral meshing with three meshers: VTK, Netgen (optional
    netgen extra) and Simpleware. Each returns one mesh per label, and
    ConvertVTKToUSD writes one UsdGeomTetMesh per label. See Breaking
    changes
    .

Enhancements

  • --composite-mode percentile with --composite-percentile for 4D CT
    reconstruction (any percentile from 0 to 100).
  • Time-series inference accepts return_transforms=False, which avoids
    retaining dense transforms and frees per-stage buffers. The default is
    unchanged.
  • Model fitting can crop to the mask and set the fitting-grid spacing at
    construction. Defaults are unchanged.
  • Segmentation backends have explicit resource cleanup. NVIDIA backends release
    cached pipelines and recreate them on reuse. The respiratory tutorials call it.
  • ProcessLabelmaps.remove_islands and fill_holes. ProcessTransforms holds
    displacement fields at their edge, so meshes beyond the field's extent no
    longer tear.

Fixes

  • Intensity images with unsupported voxel types are normalized before
    segmentation and isotropic resampling, with a guard for exact integer
    representation.

Dependencies

  • Registration uses the published icon-registration>=1.1.9 and
    unigradicon>=1.0.6; the uniGradICON fine-tuning branch override is gone.

Breaking changes

  • ProcessVolumetricMesh.extract_tetrahedra is replaced by
    extract_label_tetrahedra_vtk, _netgen and _simpleware, which return
    {label id: mesh}. Run py utils/migrate_extract_label_tetrahedra.py to
    convert calls.
  • The uniGradICON branch install is no longer needed:
    pip install --upgrade "icon-registration>=1.1.9" "unigradicon>=1.0.6".
  • See docs/developer/migration_2026.11.2.md for details.

Tooling

  • In-repository AI agent and skill definitions were removed; they now live in
    each contributor's workspace.

What's Changed

  • MNT: Strengthen Loop Kit independent review and approval gates by @aylward in #180
  • ENH: Adapt loop-kit skill for codex by @aylward in #181
  • ENH: Per-label tetrahedral meshing with vtk, netgen and Simpleware by @aylward in #182
  • FIX: Normalize unsupported intensity voxel types before ITK filters by @aylward in #183
  • ENH: Add optional mask crop and spacing for model fitting by @aylward in #184
  • ENH: Allow time-series inference without retaining dense transforms by @aylward in #185
  • ENH: Add explicit segmentation resource cleanup by @aylward in #186
  • ENH: Add percentile composites for 4D CT reconstruction by @aylward in #187
  • MNT: Use published ICON releases for fine-tuning by @aylward in #188
  • MNT: Remove in-repository AI agent and skill definitions by @aylward in #189
  • ENH: Add Warp blood-flow solvers and simplify aorta flow experiments by @aylward in #190
  • ENH: Release 2026.11.2 by @aylward in #191

Full Changelog: 2026.11.1...2026.11.2