Skip to content

v0.3.7

Choose a tag to compare

@StaRadian StaRadian released this 22 Oct 01:38
· 6 commits to main since this release

Windows viewer and firmware 0.3.7.

  • sutterspeed-viewer.exe: the viewer (no install). Plug in the board and pick its COM port.
  • sutterspeed.hex: firmware. Flash it from the viewer (chip icon, top right) or sutterspeed-viewer --flash sutterspeed.hex.

Changes since 0.3.2

  • Shutter measurement: open time from the light rising through the trigger level to falling back through it (on the filtered trace when a filter is set). The trigger looks at a 40 µs average, so fast room-light flicker no longer fires it. Works like SINGLE; the scope screen stays (dimmed) until the pulse comes, ▶ returns to the scope.
  • MIN WIDTH knob next to the filter: light has to stay past the level this long to trigger (short flashes and flicker are passed over). 0 = off.
  • Trigger works up to 10 ms/div (slower time bases roll live); NORMAL / SINGLE need the trigger on; SINGLE shows the old trace dimmed while it waits.
  • Changing the trigger level or edge no longer restarts the capture or clears the screen.
  • Stage gains learned from block means; adc console command shows channel statistics and stage ratios.
  • Viewer: drag the trace up / down, separate A / B cursor buttons, connection icon shows the real link state.