Repository navigation
AranetBar 1.2.0 adds proper multi-meter support, local meter names, and a visible version number.
Multiple meters
- Every Aranet is tracked separately by its CoreBluetooth identifier. The menu bar follows one active meter instead of whichever packet arrived last.
- Switching has hysteresis: the current meter must be quiet for about 45 seconds, or another must be at least 8 dBm stronger for 10 seconds. Two meters at similar range no longer make the reading flap.
- The new Sensor ▸ menu lists nearby meters with their CO₂ and RSSI. You can pin one; the pin releases automatically if that meter goes away, so moving to another location still follows the meter that is there.
- History is cached per meter as
history-<identifier>.json. Switching meters swaps the graph, and a snapshot from one meter is never shown under another. The old singlehistory.jsonremains available to--render-history, but is never attributed to a meter.
Friendly names
- Name Meter… gives the active meter a local name such as “Office” or “Living Room”.
- Names persist across launches and appear in the menu header, the Sensor submenu, and the History window. Leave the field blank to return to the meter’s advertised Bluetooth name.
Version
- The app version is shown above Quit AranetBar in the menu.
--versionprints the same value for scripts, e.g.AranetBar 1.2.0 (1).
Install
Download AranetBar-1.2.0.zip, unzip, and drag AranetBar.app to /Applications. It is ad-hoc signed and not notarized: on first launch, right-click → Open, or run xattr -dr com.apple.quarantine /Applications/AranetBar.app.
Full Changelog: v1.1.3...v1.2.0