Skip to content

The Maker

J edited this page Sep 22, 2026 · 1 revision

THE MAKER

Documentation 1.0 | Firmware baseline 1.0-r9

THE MAKER groups sensor, peripheral, scripting, Remote ID, and embedded-AI tools.

This category is intended for hardware experimentation, sensor inspection, peripheral discovery, scripting, Remote ID interoperability testing, and embedded AI evaluation. Depending on the selected application, POOM can use the IMU, I2C bus, Wi-Fi or BLE radio, SD card, and compiled model resources.

Press A to enter the category, use UP/DOWN to choose an application, and press A to start it. B normally returns to the menu; each application may provide additional OLED controls.

Stop an active application before opening another one so shared hardware and software resources are released correctly.

Menu options

Option What it does and why it is useful How to use it
PLOT Displays live IMU data and supports BLE plot transport. It is useful for checking acceleration, angular movement, orientation changes, sensor response, and motion behavior directly on POOM. Technically, POOM reads accelerometer and gyroscope data from the IMU and renders selected channels on the OLED, with optional transport to a compatible external plot tool. Start PLOT, choose ACC, GYR, or 6AX, keep POOM still for a reference, then move or rotate it and observe the live graph and values.
DRONE SCAN Receives supported Remote ID broadcasts and displays discovered records. It is useful for Remote ID receiver development, interoperability tests, and observing compatible broadcasts in an authorized environment. Technically, POOM listens for supported Remote ID messages over the implemented wireless transport and decodes the available fields for display. Start DRONE SCAN, wait for the list to populate, use UP/DOWN to select a record, and press A to inspect its available details.
DRONE EMUL Generates configured Remote ID test broadcasts. It is useful for validating scanners and receiver implementations without requiring a separate live transmitter. Technically, POOM builds supported Remote ID test messages and transmits them using the configured emulation mode. Start DRONE EMUL, choose the available test configuration when prompted, begin transmission, observe it with a compatible receiver, and stop the session when finished.
I2C Scans the configured I2C bus and lists responding addresses. It is useful for checking wiring, confirming that a peripheral is powered, and identifying the address used by a connected sensor or module. Technically, POOM probes I2C addresses and reports devices that acknowledge the transaction. Connect a compatible peripheral, open I2C, start the scan, and compare the responding hexadecimal addresses with the peripheral datasheet.
LUA Browses and executes Lua scripts from SD storage. It is useful for custom on-device automation, rapid experiments, and workflows that use the scripting bindings provided by the firmware. Technically, POOM loads .lua files from SD and executes them through the embedded Lua runtime and available firmware bindings. Insert an SD card, open LUA, browse to a .lua file, select it, and monitor the OLED state and any serial output produced by the script.
EDGE AI Runs the Edge Impulse integration available in the installed firmware. It is useful for testing the configured model, validating model input and output behavior, and evaluating embedded-AI workflows on POOM. Technically, the application uses the model, labels, thresholds, input flow, and connectivity defined by the current firmware build and its stored configuration. Configure the required Wi-Fi and Edge Impulse API key, open EDGE AI, follow the OLED prompt, provide the expected input, and review the displayed inference result.

PLOT

PLOT reads the IMU and renders live motion data on the OLED.

The supported view labels are:

View Displayed data Typical use
ACC Three accelerometer axes. Check movement, tilt, shock, or acceleration response.
GYR Three gyroscope axes. Check angular movement and rotation response.
6AX Accelerometer and gyroscope data together. Inspect all six motion axes during a test.

PLOT workflow

  1. Open THE MAKER > PLOT.
  2. Select ACC, GYR, or 6AX with the application's controls.
  3. Keep POOM still to establish a stable visual reference.
  4. Move, tilt, or rotate the device and observe the graph and values.
  5. Use BLE transport only when the receiving plot tool is configured to connect.
  6. Exit the application before opening another IMU or BLE tool.

PLOT is a live diagnostic visualization.

The values are useful for comparing sensor behavior, checking movement, and validating that the IMU responds as expected. They should not be treated as calibrated scientific measurements unless the complete measurement chain has been characterized for that purpose.

DRONE SCAN

DRONE SCAN receives supported Remote ID broadcasts and presents discovered records with available detail screens.

It is intended for Remote ID receiver development, interoperability testing, and authorized observation of supported broadcasts.

DRONE SCAN workflow

  1. Open THE MAKER > DRONE SCAN.
  2. Wait for the discovery list to populate.
  3. Use UP/DOWN to select a record.
  4. Press A to inspect the available details.
  5. Return to the list or exit with the controls shown by the application.

The list contains only broadcasts that POOM can receive and decode.

A device may be absent because it is out of range, not currently transmitting, using an unsupported Remote ID transport, operating on another channel, or affected by local RF conditions.

PCAP-to-SD behavior depends on the scanner configuration and installed firmware build.

DRONE EMUL

DRONE EMUL creates Remote ID test broadcasts for compatible scanners and receivers.

It is a development and interoperability tool. It is not a flight-control system and is not a replacement for a drone manufacturer's regulatory Remote ID implementation.

DRONE EMUL workflow

  1. Open THE MAKER > DRONE EMUL.
  2. Review and select the available emulation configuration.
  3. Start the emulation session.
  4. Use a compatible receiver or another POOM running DRONE SCAN to observe the test broadcast.
  5. Stop emulation before switching to another radio application.

When comparing receiver behavior, record the POOM firmware version, selected emulation mode, receiver implementation, and test conditions.

Use test transmissions only in authorized environments and in accordance with applicable local radio and aviation requirements.

I2C

I2C scans the board's configured I2C bus and reports addresses that acknowledge the scan.

It is useful when adding a sensor, checking a new module, validating wiring, or confirming that a peripheral is powered and responding.

I2C workflow

  1. Power off or disconnect POOM before wiring a peripheral when required by the hardware.
  2. Connect a compatible I2C device using the correct voltage, shared ground, SDA, and SCL connections.
  3. Start POOM and open THE MAKER > I2C.
  4. Run the scan.
  5. Record each responding hexadecimal address.
  6. Compare the address with the peripheral datasheet before selecting a driver or sending device-specific commands.

A responding address confirms only that something acknowledged the I2C transaction.

It does not identify the exact product, firmware state, register map, health, or configuration of the connected peripheral.

Do not connect devices with incompatible voltage levels. Pin assignments and supported wiring can differ between POOM hardware targets.

LUA

LUA provides an OLED interface for browsing and running Lua scripts from SD storage.

The default entry path is:

/sdcard/main.lua

The file browser filters files with the .lua extension.

LUA workflow

  1. Prepare a FAT-compatible SD card containing a Lua script, for example /sdcard/main.lua.
  2. Insert the SD card.
  3. Open SETTINGS > SD > CHECK CARD and verify that the card is available.
  4. Open THE MAKER > LUA.
  5. Browse to the desired .lua file.
  6. Select the script.
  7. Review the OLED execution state and serial output when provided by the script.
  8. Exit the application after the script finishes or when the script workflow allows it.

Lua scripts can use firmware bindings and may interact with hardware, storage, networking, or other POOM services exposed by the installed build.

Review scripts before running them. Keep backups of important SD files and do not remove the card while a script is loading, executing file operations, or saving data.

EDGE AI

EDGE AI runs the Edge Impulse integration included in the installed firmware.

The exact model, input source, labels, thresholds, output format, and runtime behavior depend on the firmware image installed on POOM.

The application uses the saved Wi-Fi configuration and Edge Impulse API key when the current workflow requires online access.

EDGE AI configuration

Configure Wi-Fi first through SETTINGS > WI-FI.

Then save the Edge Impulse API key through the POOM USB CLI.

Open THE BEAST > CLI and use:

cfg-edge-api-key-set <your_edge_impulse_api_key>

The following command is also supported as an equivalent token-setting command:

cfg-edge-token-set <your_edge_impulse_api_key>

The API key is stored in POOM's persistent secrets store and is used by the Edge Impulse application when required by the installed workflow.

EDGE AI configuration workflow

  1. Connect POOM to a computer with a USB data cable.
  2. Open THE BEAST > CLI.
  3. Open the POOM USB serial console on the computer.
  4. Run cfg-edge-api-key-set <your_edge_impulse_api_key>.
  5. Confirm the Edge token saved. response.
  6. Return to the main menu.
  7. Verify the network configuration through SETTINGS > WI-FI.
  8. Open THE MAKER > EDGE AI.

Keep the API key private.

Do not place the API key in Lua scripts, SD files, screenshots, captures, logs intended for sharing, Issues, Pull Requests, or source-code commits.

EDGE AI workflow

  1. Configure the required Wi-Fi credentials and API key.
  2. Open THE MAKER > EDGE AI.
  3. Read the state and input prompt shown on the OLED.
  4. Provide the input expected by the installed model.
  5. Wait for the model workflow or inference to complete.
  6. Review the displayed label, score, status, or other result provided by the installed firmware.
  7. Exit the application before starting another resource-intensive tool.

An inference result is a model output and should not be treated as a guaranteed classification.

When comparing model behavior between POOM devices or firmware builds, record the installed version from SETTINGS > FW INFO together with the test input and relevant model configuration.

Common operating rules

  • Verify the installed firmware version in SETTINGS > FW INFO before comparing sensor, Remote ID, Lua, or Edge AI behavior between builds.
  • Stop DRONE SCAN and DRONE EMUL before switching to another application that uses the same radio resources.
  • Use I2C peripherals only with compatible electrical levels and board-supported wiring.
  • Do not remove the SD card while Lua is loading, executing file operations, or saving data.
  • Review Lua scripts before execution because firmware bindings can provide access to device resources.
  • Keep API keys and other secrets out of source-code commits, public Issues, Pull Requests, screenshots, and shared logs.
  • Preserve test inputs, firmware version, logs, and results when reproducing sensor or model behavior.
  • Exit resource-intensive applications before starting another function that uses the same hardware or connectivity resources.

Implementation references

Development and support

Clone this wiki locally