Release v1.5.4

Pre-release
Pre-release

Choose a tag to compare

@github-actions github-actions released this 03 Nov 20:05

[V1.5.4.0] - 2026-11-03

Target specification: SRCI V1.5.9 (2024-12-04). Known error of the specification (confirmed by PI):
the AxesGroupID starts at 0, not at 1.

Added

  • ST-FIX F109: four command types of the specification had no function block: MC_MoveDirectCamFB (2401, mandatory, Profile Extended; template MoveLinearCam, byte 15 reserved instead of OriMode), MC_ReadAnalogOutputFB (6108, optional; like ReadAnalogInput), MC_ReadSafeReferencePositionFB (7009) and MC_SafeReferencingFB (7010, additional features); CmdType.ReadSafeReferencePosition / SafeReferencing and their names in CMD_TYPE_TO_STRING. Telegrams as in the spec tables (table 6-832 of ReadSafeReferencePosition is a copy of ReadActualPosition; the SRCI SDK puts MaximumDistance of SafeReferencing one byte later than table 6-838). Tested with SRCI_PY and the TcUnit project SRCI_PLC_TEST_SUITE against the modified SDK by Thorsten (complete run 1857 tests, 0 failed)

Fixed

Fixes of the findings F110 … F152, found with validation tests against the SRCI SDK and
tested in the TcUnit project SRCI_PLC_TEST_SUITE (3749 tests; the failures of the complete run of 2026-11-02 fixed and retested green).
Every change is marked in the code with // ST-FIX Fnn.

  • ST-FIX F110: MC_WriteIntegersFB.CheckParameterValid – ParCmd.Values[_idx] < 0 OR ParCmd.Values[_idx] > 4294967295 rejects every negative value with ERR_INVALID_PAR_CMD (16#0008), although Values is ARRAY[0..6] OF INT; the upper bound (UDINT range) can never be reached with INT - copy of an unsigned range check. Fix: range check removed
  • ST-FIX F111: CheckParameterValid of the motion blocks with ConfigMode (seen in MC_MoveLinearAbsoluteFB, MC_MoveDirectAbsoluteFB) – an undefined ParCmd.ConfigMode.Shoulder/Elbow/Wrist is rejected with the generic ERR_INVALID_PAR_CMD (16#0008); the codes 16#8405..16#8407 are used for ParCmd.Position.Config instead
  • ST-FIX F112: CheckParameterValid of the motion blocks (MC_MoveAxesAbsoluteFB, MC_MoveLinearAbsoluteFB, MC_MoveDirectAbsoluteFB, probably all with BlendingParameter) – an invalid BlendingParameter sets ERR_JERK_INVALID and logs JerkRate (copy of the jerk check); the RETURN after EXIT is never reached, so later checks may overwrite the ErrorID
  • ST-FIX F114: ActiveCommandRegisterFB._set_NotifyParameterChanged, called by CheckParameterChanged of the generated blocks – a ParCmd change in the first Busy cycle, before the command is sent, turns the CREATED entry into UPDATE_AVAILABLE; the command is never sent and ends with ERR_TIMEOUT_CMD after 5 s
  • ST-FIX F115: MC_WriteFrameDataFB (~588), MC_WriteToolDataFB (~648), MC_WriteLoadDataFB (~657) – the user data array is updated for every final state (State >= DONE, also ERROR / ABORTED): a write refused by the RC (16#8C13, 16#8D17, 16#8D49) still marks the data as available with the refused values
  • ST-FIX F118: MC_ReturnToPrimaryFB.OnExecRun – the falling edge of Enable resets the block without sending the Enable bit FALSE to the RC: the robot keeps returning and CommandAborted is never shown
  • ST-FIX F119: MC_CreateServerLogFB.CheckParameterValid (~227) – NOT ProcessingMode >= TRIGGER_BUFFERED is a bitwise NOT of the INT (operator precedence): TRUE for every mode, so every trigger mode with ListenerID > 0 is rejected with 16#8605
  • ST-FIX F120: MC_CallSubprogramFB.OnUpdateStateFlags – ParameterAccepted is never set (other blocks set it on BUFFERED)
  • ST-FIX F121: MC_CallSubprogramFB.OnApplyOutCmd – OutCmd.InstanceID := 0 (ToDo): StopSubprogram with StopMode 1 (by InstanceID) cannot work. Fix: InstanceID = ID of the command in the ACR
  • ST-FIX F122: MC_ReadActualPositionFB.CheckParameterValid – ProcessingMode 4..8 (not defined) gives 16#8603 'not allowed' instead of 16#8602 'not defined'; only values outside 0..14 give 16#8602. Fix: ProcessingMode 4..8 gives 16#8602 also in CallSubprogram
  • ST-FIX F123: MC_ReadActualPositionCyclicFB.OnExecRun step 1 – only J1..J6 of the cyclic joint position are copied, E1 stays 0
  • ST-FIX F127: MC_GroupJogFB.Reset (~758) – Active is not cleared, it stays TRUE after Enable FALSE; unreachable code after RETURN in OnExecRun (~653-658)
  • ST-FIX F128: MC_GroupJogFB – an invalid ToolNo while jogging sets Error at once, but the jog on the RC keeps moving until Enable FALSE (safety relevant)
  • ST-FIX F129: MC_EnableRobotFB.CheckSynchronizationValid – runs in every cycle while Enable is TRUE and sets ERR_SYNC_STATE_PROHIBITS_COMMAND as soon as Synchronized is FALSE, independent of SyncReaction: the block drops Enabled although the RC keeps the robot enabled
  • ST-FIX F130: MC_RobotTaskFB.CheckParameterValid – an invalid SyncMode also sets the own error ERR_SYNC_MODE_INVALID and stops the initialization; the spec defines only the warning WARN_*_SYNC_MODE_INVALID
  • ST-FIX F131: MC_RobotTaskFB.CheckParameterChanged – returns when Initialized is FALSE, and Initialized := NOT Synchronized (ToDo): a mode change while synchronized is reported only after the synchronization is lost
  • ST-FIX F132: MC_RobotTaskFB – ERR_AXESGROUP_INVALID (16#8007) and ERR_PERIPHERY_INVALID (16#8008) are defined but never set: a second RobotTask on the same AxesGroup / telegram buffers is not rejected
  • ST-FIX F133: OnApplyOutCmd of the motion blocks, MC_ForceLimitFB, MC_SetTrigger*FB (21 blocks) – OutCmd.FollowID is the OriginID of the response or 0; the triggered action reports another ID. Fix: _uniqueID
  • ST-FIX F134: MC_CallSubprogramFB.OnApplyOutCmd – OutCmd.InstanceID := 0 (ToDo, see F121). Fix: ID of the command in the ACR
  • ST-FIX F135: RobotLibraryBaseEnableFB (all Enable blocks) – Enabled stays TRUE after the falling edge of Enable until the RC answers
  • ST-FIX F136: MC_WriteCallSubprogramCyclicFB.OnExecRun – no check of the supported function, Enabled follows Enable directly, data written while not enabled. Fix: step chain like ReadCallSubprogramCyclic
  • ST-FIX F137: MC_RobotTaskFB.CheckParameterValid – Use*PositionExt without Use*Position was rejected (cartesian) or not checked (AND FALSE, joints). Fix: supersedes F124
  • ST-FIX F138: MC_RobotTaskFB.OnCall – an invalid AxesGroupID sets the internal error 3. Fix: default 0 kept
  • ST-FIX F139: MC_ReturnToPrimaryFB.OnApplyOutCmd – PrimaryPosToolNo / PrimaryPosFrameNo converted with UINT_TO_USINT. Fix: type change only, no runtime test
  • ST-FIX F140: MC_RobotTaskFB.ParseRecvPayload – the SEQ_ACK check covers only the first sequence
  • ST-FIX F141: MC_ReturnToPrimaryFB.OnExecRun step 10 (after F118) – with the SDK the block waits for an end state after Enable FALSE that never comes (Busy/Active stay TRUE, robot keeps moving). Workaround: ParSeq) without ending the command; ToDo: remove when the SDK aborts (TcUnit SDK_RTP_006/010
  • ST-FIX F142: MC_CalculateToolFB.CheckParameterValid – the check "PositionsArray[x].E2 valid" tests E1 (copy error): NaN / infinity in E2 is sent to the RC
  • ST-FIX F143: MC_MovePickPlaceDirectFB, MC_MovePickPlaceLinearFB .CheckParameterValid – BlendingParameter[0..1] is not checked: NaN / infinity is sent to the RC
  • ST-FIX F144: MC_ShiftPositionFB.CheckParameterValid – RotationAngle is not checked: NaN / infinity is sent to the RC
  • ST-FIX F145: MC_WriteWorkAreaFB.CheckParameterValid – the limits of the external axes E1Limit..E6Limit (Lower/UpperLimit) are not checked, J1..J6 are: NaN / infinity is sent to the RC
  • ST-FIX F146: MC_FreeDriveFB, MC_PathAccuracyModeFB .CheckParameterChanged – the method returns at once when ParCmd is empty (SIZEOF(ParCmd) = 0), before the internal update _parameterUpdateInternal is handled: the update with Enable FALSE is never sent, the block stays Enabled / Busy and the RC keeps the function enabled. Fix: RETURN only without active step, MemCmp only for a non-empty ParCmd
  • ST-FIX F147: OnUpdateStateFlags of the "Enable" blocks (ForceControl, ForceLimit, ActivateConveyorTracking, SyncToConveyor, DynamicSpline, MonitorWorkArea, UnitMeasurement, AvoidSingularity, ExchangeConfiguration, OpenBrake, ...) – ParameterAccepted is set only for BUFFERED / BUFFERED_IN_PLANNER; a function the RC answers ACTIVE at once and every acknowledged parameter update (response ParSeq = command ParSeq) never show it
  • ST-FIX F148: MC_LoadMeasurementSequentialFB.CheckParameterValid – a ProcessingMode other than Buffered / Aborting / Parallel sets ERR_ABORTINGMODE_INVALID (16#8411)
  • ST-FIX F149: MC_ActivateNextCommandFB, MC_RedefineTrackingPosFB .OnApplyOutCmd – InvocationCounter / OriginID are copied only in state DONE: in Trigger Multiple the command stays ACTIVE and OutCmd.InvocationCounter stays 0 although the RC counts every trigger. Fix: copied in ACTIVE and DONE
  • ST-FIX F150: MC_MoveSuperImposedDynamicFB.OnExecRun – the falling edge of Enable only calls Reset() (Busy, Active, CommandBuffered, ParameterAccepted FALSE): Enabled stays TRUE, no telegram is sent and the superimposed function stays ACTIVE on the RC. Fix: falling edge of Enable sends the disable update with STOP_PARALLEL_CONTINUOUS_TRIGGER and waits for the response; the SDK answers ABORTED
  • ST-FIX F151: MC_RobotTaskFB.HandleAxesGroupParameter – until the RC configuration is exchanged, AxesGroup.Parameter is copied from the input ParCfg in every cycle; the corrections of CheckParameterValid (e.g. F137: base position switched on for an extended position) are lost because the caller writes ParCfg again: the telegram number changes during the start-up, the RC answers ERROR_169 and the RobotTask never initializes. Fix: _parCfg while _stepCmd > 0
  • ST-FIX F152: CheckParameterValid of 33 blocks (dynamics rates of all motion blocks, Override, GroupJog, CollisionDetection, SoftSwitchTcp, SafeReferencing, splines, superimposed motions, WriteRobotDefaultDynamics; 124 conditions) – IF (SysDepIsValidReal(x) = FALSE) OR (x < 0) OR ...: ST evaluates OR completely, so x < 0 is also evaluated when x is NaN; in TwinCAT an ordered comparison with NaN raises an FPU exception (0xC0000090, SSE invalid operation) and the PLC stops. Python does not show it: the transpiled or short-circuits. Fix: OR_ELSE in these conditions, TcUnit ValPar green
  • MC_RobotTaskFB.ParseRecvPayloadCyclicOptional: the loop over SubProgramData.Data ends at
    SIZEOF(...Data) - 1 instead of the literal 25 (UPPER_BOUND on a fixed array is refused by older compilers)

[V1.5.3.0]

Added

  • ST-FIX F108: the mandatory Core functions CreateServerLog (9003) and ReadServerLog (9004) were only empty placeholders (MC_CreateServerLog_ToDo, MC_ReadServerLog). New: MC_CreateServerLogFB (Execute, ProcessingMode / SequenceFlag / ListenerID like the other trigger capable commands, OutCmd.ServerLogID) and MC_ReadServerLogFB (Execute; reads the server log ParCmd.ServerLogID (-1 latest, 0 oldest) from ParCmd.StartLine on with ParCmd.ContextFilter line by line into the in-out array LogFile : ARRAY[*] OF STRING(RobotLibraryParameter.LOG_LINE_LEN), joins the parts of a line, ends with Done when the RC reports the end of the log or LogFile is full; Execute may be reset during the transfer; a new rising edge starts it again; ExportMode 1 (optional export to a file) is rejected with 16#8419). CmdType.CreateServerLog / ReadServerLog, RobotLibraryConstants.SERVER_LOG_CONTENT_MAX (179), RobotLibraryParameter.LOG_LINE_LEN (1023). Telegram layout of the SRCI SDK 1.1 (Siemens): the command has Offset (request counter, bytes 12-15, ContextFilter from byte 16), the response the bits IsStartOfLine / IsEndOfLine / EndOfLogReached (byte 13), LogLine, Offset and up to 179 characters; spec tables 6-116 (ends at byte 7), 6-123 and 6-124 differ. Tested with SRCI_PY against the SDK (SDK-LOG-001 ... 014) (spec: 6.2.5, 6.2.6, 5.5.11.8)
  • The placeholders MC_CreateServerLog_ToDo / MC_ReadServerLog are removed after the TcUnit tests of the new blocks

[1.5.2.0]

Fixes of the findings F104 … F107, found with the new SDK tests of SRCI_PY and ported and tested in the
TcUnit project SRCI_PLC_TEST_SUITE (complete run 1780 tests, 0 failed). Every change is marked in the
code with // ST-FIX Fnn. Details and the diffs: SRCI_PY docs/ST_FINDINGS.md and
docs/ST_Finding_Solve_Guide.md.

Fixed

  • ST-FIX F104: RobotLibraryBaseExecuteFB and the 32 blocks with ProcessingMode DEACTIVATE (MC_ReadActualPositionFB, MC_ReadDigitalInputsFB, MC_SetTrigger*FB, MC_Write*DataFB, ...) – a CONTINUOUS / trigger command could not be ended: F50 holds Execute while Busy, so a new rising edge with ProcessingMode DEACTIVATE never reached the block (stays Busy / Valid forever, the RC keeps the command active); found by the SDK test SDK-STAT. Fix: RobotLibraryBaseExecuteFB detects the rising edge of the Execute input (_executeRestart_R); in OnExecRun step 1 the blocks send the same command again with ParSeq + 1 and execution mode Stop (CreateCommandPayload, NotifyParameterChanged), the RC answers DONE (spec: 5.5.12.4 (change of ProcessingMode only with a new rising edge), 5.6.4.5, table 5-77)
  • ST-FIX F105: RobotLibraryBaseFB (messages of F74) – the user defined command name (Name) was not part of the message in the message buffer (only the block type). Fix: _messageSource = <type> [<Name>] when Name is set, used in the message texts (spec: 5.5.11, table 5-47)
  • ST-FIX F106: OnUpdateStateFlags of MC_EnableRobotFB, MC_GroupJogFB, MC_ExchangeConfigurationFB, MC_ReadMessagesFB and 6 more enable blocks with Enabled from the response – an error response has no payload (only the header), Enabled kept the value of the last response: e.g. after a change of the operation mode the RC switches the power off, MC_EnableRobotFB showed Error (16#8C03) and Enabled TRUE. Fix: Enabled := FALSE with state ERROR (MC_EnableRobotFB also ABORTED) (spec: 5.5.5 (error: header only))
  • ST-FIX F107: MC_RobotTaskFB.HandleSync{Tool,Frame,Load}Data, HandleSyncWorkArea, HandleSyncRobot{SWLimits,DefaultDynamics,ReferenceDynamics} step 21 – AUTOMATIC: PLC data changed while the client read the data changed on the RC were overwritten with the older RC data and written back to the RC (F20), the newer PLC change was lost without a message; found with RC-side data changes in the SDK harness (SDK-SYNC). Fix: with AUTOMATIC and PLC data <> internal copy no copy, step 30 (write the PLC data to the RC) (spec: 5.6.7.2 "Automatic": the most recently changed data win)

[1.5.1.0]

Fixes of the findings F1 … F103 found while porting the library to Python (SRCI_PY) and testing both
against the SRCI SDK (SDK in the loop, TcUnit project SRCI_PLC_TEST_SUITE). Every change is marked in the
code with // ST-FIX Fnn. Details and the diffs: SRCI_PY docs/ST_FINDINGS.md and
docs/ST_Finding_Solve_Guide.md.

Added

  • New functions TURN_TO_SIGN_MAGNITUDE and SIGN_MAGNITUDE_TO_TURN (turn numbers as sign + magnitude, ST-FIX F3)
  • New error and info IDs of the specification (ST-FIX F75)

Changed

  • MC_RobotTaskFB: the telegram methods CreateSendPayload, CreateSendPayloadHeader/Cyclic/CyclicOptional, ParseRecvPayload, ParseRecvPayloadHeader/Cyclic/CyclicOptional, CalculateTelegramLengthPlcToRob and HandleSync are PROTECTED (were PRIVATE), so a derived block can test the telegram coding (TcUnit RobotTaskProbeFB). No change of the behaviour.

Fixed

  • ST-FIX F1: MC_RobotTaskFB.CreateSendPayloadCyclicOptional – Cartesian position PLC→RC: Config is sent as 1 byte, but SIZEOF(...CartesianPosition) = 34 counts 2 bytes → all following bytes are shifted by one compared to the calculated layout. Fix: 2 bytes (config, 0) (spec: Table 5-97: Config = bytes 24–25)
  • ST-FIX F2: MC_RobotTaskFB.CreateSendPayloadCyclic, CalculateCyclicDataLength – ToolNo/FrameNo are always sent after the header. Fix: only with RobToPlc.CartesianPosition.Active (confirmed with the SDK in M5) (spec: Table 5-88 bit 1 / 5-90 and SDK (AutoTransmitCartesianPos): only when "Cartesian Position" RC→PLC is configured; otherwise the RC expects the sequence at byte 18)
  • ST-FIX F3: RobotLibrarySendDataBaseFB.AddTurnNumber, RobotLibraryRecvDataBaseFB.GetTurnNumbers – turn numbers encoded as two's complement nibble (SINT_TO_BYTE, -1 → 2#1111 = -7 for the RC); decoding ignores the sign bit (-1 = 2#1001 → 9) (spec: 5.5.4.4, tables 5-24…5-26: sign + magnitude, bits 0..2 value, bit 3 sign (E1: bits 0..6, bit 7))
  • ST-FIX F5: MC_RobotTaskFB.ParseRecvPayloadSequence – _fragIdx and _seqPayloadPtr are not reset for the second sequence – with two sequences the second one is parsed with a wrong fragment index/length. Fix: reset per sequence
  • ST-FIX F6: DwordToRaStatusWord – inserts CollisionDetectedEnabled at bit 13 → CollisionDetected, RestartRequested, Accelerating, Decelerating, ConstantVelocity are read one bit too high. Fix: CollisionDetectedEnabled stays FALSE (spec: Table 5-105 and SDK: 13 CollisionDetected, 14 RestartRequested, 15 Accelerating, 16 Decelerating, 17 ConstantVelocity)
  • ST-FIX F9: ByteToAxisJointUnit – bit 1 and bit 2 both assigned to J2, J1 never set. Fix: J1..J6 = bits 1..6 like ByteToAxisJointUsed
  • ST-FIX F10: PERCENT_INT_TO_REAL – compares an INT with 16#FFFF_FFFF/16#0000_FFFF; depending on the implicit conversion -1 (16#FFFF) is not recognised as "not supported". Fix: intended meaning implemented: all 16 bits set → -1.0 (spec: 5.6.2 percentage encoding)
  • ST-FIX F12: MC_MeasuringInputFB.CheckParameterValid – SetError( ErrorID := ErrorID := ...) – duplicated assignment in the argument list. Fix: single ErrorID :=
  • ST-FIX F13: MC_RobotTaskFB.HandleSync – HandleSyncToolData is called twice per cycle (the tool step chain runs at double speed, e.g. Execute set and evaluated in the same cycle): single call
  • ST-FIX F14: MC_RobotTaskFB.HandleAxesGroupSystemData – FrameDataPtr/WorkAreasPtr (and Min/Max) are set to LoadData (copy & paste) – frame and work area data are written into the load array. Fix: FrameData / WorkAreas
  • ST-FIX F15: MC_RobotTaskFB.OnExecRun step 1 – timeout check (State >= ERROR_161) OR (State <= ERROR_173) is always TRUE → ErrorID := TelegramState also for non-error states: AND
  • ST-FIX F16: MC_Read*FB (tool/frame/load/SW limits/dynamics) during the synchronisation – the start-up read calls AxesGroup.SystemData.Update* and so overwrites the user data with the RC data before the comparison – with CLIENT_TO_SERVER the PLC data is lost and the comparison always finds equal data. Fix: new input UpdateSystemData (default TRUE) of the 7 read blocks, FALSE for the internal instances of the RobotTask; update only on DONE (spec: 5.6.7.3: client data wins)
  • ST-FIX F17: MC_RobotTaskFB.HandleAxesGroupState – Unified*Index := MIN(..., X_MAX, ...) but the internal arrays are [0..X_MAX-1] → write/read behind _toolData etc.. Fix: X_MAX - 1)
  • ST-FIX F18: MC_RobotTaskFB.HandleSync*Data – copy loops run over the user array bounds (ToolDataMin..ToolDataMax) on the internal arrays [0..TOOL_MAX-1] → out of bounds if the user array is longer than TOOL_MAX (Python raises IndexError): loops limited to X_MAX - 1
  • ST-FIX F19: ActiveCommandRegisterFB.AddRsp – FOR _idx := PayloadPointer TO PayloadLength - 1 – for fragments after the first one (PayloadPointer > 0) nothing is copied, long responses (e.g. ReadRobotData, 134 bytes) are truncated. Fix: PayloadPointer + PayloadLength - 1) (spec: 5.6.5 fragmentation)
  • ST-FIX F20: synchronisation SERVER_TO_CLIENT – after reading the RC data the client never writes it back, so DataChanged on the RC is not reset and the RC never reports DataInSync → RI state never "Synchronized". Fix: after the read (step 21) the RC data is written back (step 30) if the RC supports the write command (spec: 5.6.7.4.2: "RobotTask then executes internally WriteToolData to reset DataChanged"; SDK resets DataChanged only on write)
  • ST-FIX F21: synchronisation CLIENT_TO_SERVER – writes tool/frame/load 0 (flange, world, …); the RC rejects it (SDK 0x8D35 invalid tool number) → warning, sync fails. Fix: tool/frame sync starts at index 1 (loops, start index, LIMIT(1, …)), like LoadData (spec: 5.5.4: index 0 is fixed (flange))
  • ST-FIX F22: MC_ReadMessagesFB.ParseResponsePayload – reads the 255 byte message text at offset 20 of the 256 byte response buffer (GetDataBlock copies behind the buffer). Fix: in GetDataBlock: missing bytes are 0
  • ST-FIX F23: RobotLibraryBaseEnableFB / MC_RobotTaskFB.Reset – disabling the RobotTask starts the cancel of the enable FBs (_cancel, 5 s timeout); a new enable within this time lets the pending cancel reset MC_ReadMessagesFB after its first response → start-up hangs in step 3. Fix: a rising edge of Enable ends a pending cancel/error clear; a restart while the RC is still INITIALIZED resets the interface (Control := RESET, _restartReset)
  • ST-FIX F24: MC_RobotTaskFB.HandleSync – a data set enabled for synchronisation whose functions the RC does not support (e.g. work areas in the SDK) keeps Synchronized FALSE forever. Fix: _inSync*Ok also TRUE if the RC does not support read + write (after Initialized) (spec: 5.6.7.1: "…or not supported by the RC does not impact the RI state Synchronized")
  • ST-FIX F25: Valid output of MC_ReadActualPositionFB (and MC_ReadActualTCPVelocity, MC_ReadActualForce, MC_ReadAnalogInput, MC_ReadDigitalInputs/Outputs, MC_ReadIntegers, MC_ReadReals, MC_ReadSystemVariable, MC_CallSubprogram, MC_ActivateConveyorTracking, MC_SetTriggerLimit) – Valid is never set to TRUE. Fix: output Valid (F25_POUS) (spec: 6.1.5: Valid like Done (TRUE while updated in Continuous))
  • ST-FIX F26: CheckParameterValid of 31 FBs – IF ProcessingMode < BUFFERED AND ProcessingMode > TRIGGER_MULTIPLE is never TRUE. Fix: range check before the enum conversion
  • ST-FIX F27: MC_ReadToolDataFB, MC_ReadFrameDataFB .ParseResponsePayload – DataChanged parsed before the index (ToDo "swapped compared to V1.3") → ToolNoReturn/FrameNoReturn = DataChanged; the sync updates the wrong tool/frame (spec: tables 6-184/6-190 (and SDK): index, then DataChanged (as MC_ReadLoadDataFB))
  • ST-FIX F28: CheckAddParameter of 32 FBs (list F28_POUS in tools/st2py/config.py) – a parameter is omitted when the bytes of _command behind the payload position are zero; this assumes payload order = structure layout. Where it differs non-zero parameters are dropped, e.g. WriteToolData: ToolNo (payload end, structure start) not sent → SDK 0x8D35; WriteRobotSWLimits: upper limits not sent (structure J1Lower, J1Upper, …; payload all lower, then all upper); MC_EnableRobotFB.HoldToRun; E2..E6 of positions. Fix: CheckAddParameter := TRUE (complete payload); tests/unit/tools/test_st2py_f28.py recomputes the list
  • ST-FIX F29: MC_RobotTaskFB.OnExecRun step 8 – Initialized := NOT ERROR AND NOT Synchronized; Initialized := NOT Synchronized; – the 2nd line (ToDo) overwrites the first → after an error (e.g. init lost 0x80A2) Initialized and CMDsEnabled are TRUE again, FBs stay Busy forever. Fix: 2nd line removed: FBs end with ERR_COMMANDS_NOT_ENABLED
  • ST-FIX F30: MC_ReadRobotDataFB.ParseResponsePayload – InterpreterCycleTime read with GetUsint → 0 (SDK 10 ms) (spec: table 6-18 / SDK: UINT)
  • ST-FIX F31: MC_WriteRobotSWLimitsFB.CreateCommandPayload – ResetToFactoryDefaults (byte 106) is never sent (spec: table 6-209)
  • ST-FIX F32: responses of GroupStop, ExchangeConfiguration, ReadRobotSWLimits, ReadMessages – fields at the end are not read: AbortedSequence, NumberOfServerLogs, DataChanged; the message text has 150 characters, ST reads 255 (F22). Fix: fields added (FieldAdd) and parsed (spec: tables 6-290, 6-87, 6-203, 6-108)
  • ST-FIX F33: payload of 24 extended/optional FBs – layout differs from the spec tables (the bilateral test also found MC_LoadMeasurementAutomaticFB: Position_1 complete before Position_2) (shifted by missing/additional bytes, wrong data types, off-by-one loops). List with details: KNOWN in tests/unit/fb/test_payload_spec.py. Fix: source patches, spline one point per command (spec: chapter 6 payload tables)
  • ST-FIX F34: MC_UserLoginFB, MC_SwitchLanguageFB – AddString writes only the actual length; the spec has fixed fields (Password/Username 50, LanguageCode 2) → Username at the wrong offset. Fix: source patches (spec: tables 6-69, 6-76)
  • ST-FIX F35: CmdType enum, MC_MoveLinearAbsoluteJFB, MC_SoftSwitchTcpFB – wrong command types: MoveLinearAbsoluteJ is sent as MoveLinearAbsolute (2103) – the RC reads the joint target as Cartesian position; SoftSwitchTcp as ShiftPosition (7205); MoveCircularAbsolute 2109 / MoveCircularRelative 2106. Fix: enum override in tools/plcopen_gen/overrides.py, source patches (spec: spec: MoveLinearAbsoluteJ 2109, SoftSwitchTcp 7300, MoveCircularAbsolute 2106, MoveCircularRelative 2107)
  • ST-FIX F36: MC_SearchHardStopFB, MC_SearchHardStopJFB .CheckParameterValid – FOR _idx := 0 TO 6 over DetectionVector[0..5] – reads behind the array (Python: IndexError)
  • ST-FIX F37: MC_EnableRobotFB, MC_MoveCircularRelativeFB .CreateCommandPayload – two BOOLs that are bit 0/1 of one byte are sent as two bytes (HoldToRun/ManualStep, PathChoice/Manipulation) → ManualStep/Manipulation land in a reserved byte (not visible in the layout check, sizes happen to fit) (spec: tables 6-25, 6-357)
  • ST-FIX F38: MC_ReturnToPrimaryFB.CreateCommandPayload – AllowDifferences is never copied into the command → always FALSE (spec: table 6-332)
  • ST-FIX F40: MC_UnitMeasurementFB, MC_SyncToConveyorFB .OnApplyOutCmd – OutCmd is only updated in state ACTIVE – the values of a response that is DONE at once are lost
  • ST-FIX F41: defaults of ParCmd (VelocityRate, AccelerationRate, DecelerationRate, JerkRate, ...) – default 0.0 = "internal minimal" velocity/acceleration; the spec defines "<0 %: (default) use default" → a command with the default values moves with minimal dynamics or is rejected (SDK: DecelerationRate 0 → 0x8E03). Fix: rates default -1.0 (FieldOverride), -1.0 → 16#FFFF (spec: chapter 6, e.g. 6.3.2.3)
  • ST-FIX F42: MC_OpenBrakeFB – Execute block; the spec defines OpenBrake with Enable (brakes stay open while Enable). Fix: MC_OpenBrakeFB cloned from MC_FreeDriveFB as enable block (spec: 6.x OpenBrake)
  • ST-FIX F43: MC_FreeDriveFB – output Enabled is never set (only OutCmd.Enabled)
  • ST-FIX F44: defaults of several blocks – no valid default: ExchangeConfiguration.LifeSignTimeOut, SetSequence.TargetSequence, SetOperationMode.OperationMode, CollisionDetection.SequenceFlag, Read/WriteLoadData.LoadNo 0, SwitchLanguage/UserLogin (empty), ForceControl, ReadAnalogInput, MoveSpline, SetTriggerRegister. Fix: defaults (ForceControl ErrorReaction, MoveSpline MoveTime); mandatory parameters documented (spec: Siemens test "valid CMD with the default values")
  • ST-FIX F45: interface of 23 blocks – inputs/outputs of the spec missing or named differently (list KNOWN_MISSING in tests/unit/fb/test_interface_spec.py, e.g. ReadActualPosition: spec Enable/ReadCartesianPosition/..., WaitTime.Time, GroupStop/SetSequence output Active). Fix: outputs added (VarAppend) + name mapping in the interface test (spec: "Associated command/response values")
  • ST-FIX F46: StopSubprogramOutCmd.OriginID, ReadRobotDataOutCmd.RCInterpreterVersion – no comment. Fix: comments added (FieldOverride doc)
  • ST-FIX F47: MC_ExchangeConfigurationFB, MC_ReadMessagesFB, MC_ReadRobotDataFB – without running RobotTask they stay Busy without error (all other blocks: error). Fix: via the command timeout F53
  • ST-FIX F48: 77 blocks – an undefined ExecMode (e.g. 18) is neither checked by the block nor rejected by the RC. Fix: undefined ExecMode → error, not sent (spec: Siemens "AbortingMode is not defined")
  • ST-FIX F49: StopSubprogram.SequenceFlag, MoveLinearRelative.ReferenceType, MovePickPlaceDirect/Linear.BlendingMode, WriteAnalogOutput.Unit, CollisionDetection.ProcessingMode/SequenceFlag – undefined enum values are not checked. Fix: enum checks in CheckParameterValid
  • ST-FIX F50: base of all Execute blocks – a falling edge of Execute before the end cancels the command: Execute for one cycle → nothing is sent; reset during the motion → motion runs, but Done is never shown. Fix: Execute edge held until the command ends (_executeIn/_executeHold) (spec: 5.5.x "Output status": the falling edge "does not stop or even influence the execution", outputs set for at least one cycle)
  • ST-FIX F51: motion blocks: inputs AbortingMode, SequenceFlag – checked but not used: the telegram always has the ExecutionMode of the input ExecMode → AbortingMode = ABORT has no effect (the new command is buffered). Fix: ExecutionMode from AbortingMode/ProcessingMode/SequenceFlag (table 5-77) (spec: 5.6.4.5)
  • ST-FIX F52: MC_RobotTaskFB receive part (RecvData, fragment loop) – at most FRAGMENT_MAX + 1 = 10 fragments of a received telegram are parsed, the others are dropped with a DEBUG message only - but the telegram is acknowledged, so the RC considers them delivered → the responses are lost and the function blocks stay Busy forever (e.g. 16 GroupInterrupt in one cycle: the SDK sends 12 DONE fragments in one telegram, 2 are lost). Fix: FRAGMENT_MAX = 31; overflow logged as ERROR (spec: 5.6.5.3: no limit of fragments per telegram (header 8 bytes, a 256 byte telegram holds up to 27 fragments))
  • ST-FIX F53: 112 function blocks, OnExecRun – SetTimeout(PT := _timeoutCmd, ...) is called, but the timer is never evaluated while waiting for the response → no error when a response never arrives (see F52). Fix: command timeout
  • ST-FIX F54: MC_CreateSplineFB, MC_DynamicSplineFB – loops FOR _idx := 0 TO SPLINE_DATA_MAX over SplineData[1..SPLINE_DATA_MAX] → access before the array: loop from 1
  • ST-FIX F55: MC_CreateSplineFB, MC_DynamicSplineFB .CreateCommandPayload – the positions of the spline points are never copied into the command → always 0 sent (spec: tables of CreateSpline / DynamicSpline)
  • ST-FIX F56: MC_RobotTaskFB.HandleSeqAck – the Seq number wraps from 254 to 0; an Ack of 0 equals the Ack of telegrams without new data → the response of that sequence is ignored, the block hangs (after 255 sequences): wrap to 1 (test_sequence_number_overflow); the fix is part of the new HandleSeqAck of F63 (solve guide F63) (spec: 5.6.5.3: 0 only on the first exchange)
  • ST-FIX F57: MC_RobotTaskFB.HandleSync* step 10 – the local change detection compares with IgnoreTimestamp := FALSE, but the internal copy holds the timestamp of the RC from the start-up read → every data set counts as changed on the PLC; together with the RC "not in sync" → warning "both sides changed", no synchronisation: IgnoreTimestamp := TRUE
  • ST-FIX F58: MC_RobotTaskFB.HandleSync* step 10 – data changed on both sides only sets the warning WARN_*_SYNC_BOTH_SIDES_CHANGED, also with a fixed direction (CLIENT_TO_SERVER / SERVER_TO_CLIENT) → synchronisation stops: step 11 / 12 for the fixed directions, warning only for AUTOMATIC (spec: 5.6.7.4: the direction decides)
  • ST-FIX F59: MC_RobotTaskFB.AxesGroupFromTelegramCyclicOptional, MC_ReadActualPositionCyclicFB.OnExecRun – the RobotTask writes the currently used tool/frame (bytes 36..37 of table 5-89) into CoordinateSystem; ReadActualPositionCyclic compares it with the requested ToolNo/FrameNo → as soon as a motion uses another tool the outputs are never updated again (all zero), Enabled stays TRUE; the output CoordinateSystem is never set. Fix: new field CurrentCoordinateSystem in AxesGroupCyclicOptionalDataCartesianPosition, CoordinateSystem from bytes 34..35, both outputs set (found by the Core example) (spec: 6.1.6: CoordinateSystem = tool/frame of the returned position, CurrentCoordinateSystem = currently used)
  • ST-FIX F60: MC_RobotTaskFB.AxesGroupFrom/ToTelegramCyclicOptional, CombineHalfSints – turn numbers of the optional cyclic Cartesian position are decoded/encoded as two's complement nibble (like F3). Fix: source patches + CombineHalfSints (spec: 5.5.4.4 sign + magnitude)
  • ST-FIX F61: RobotLibraryBaseFB (body, CallBack, ParseResponsePayload) – Error := ErrorID <> 0 is computed in OnCall before the parameter check / response evaluation → one cycle ErrorID ≠ 0 with Error = FALSE; with a parameter error Execute is TRUE without any of Busy/Done/Error; ACR full (16#8618) leaves Busy and Error TRUE; GroupJog Active and Error TRUE; response state ERROR without error code ends the FB without Done and without Error (spec audit B-01…B-05). Fix: at the end of the body and of CallBack: Error := ErrorID <> OK, with Error OnUpdateStateFlags(ERROR) (resets Busy/Active/Done of every FB); state ERROR without code → 16#8613 (spec: 5.5.10, table 5-45 (Busy/Done/Error/CommandAborted exclusive), table 7-1 16#8613)
  • ST-FIX F62: RobotLibraryBaseFB.ParseResponsePayload – every response clears InfoID/WarningID/ErrorID (also warnings of the client, e.g. from the parameter check) (B-06). Fix: IDs are only overwritten by reported messages, cleared by Reset (spec: 5.5.10: IDs are held like Done until the falling edge of Execute/Enable)
  • ST-FIX F63: MC_RobotTaskFB: HandleSeqAck, AxesGroupToTelegram(Sequence), CheckParameterValid, telegram coding (CreateSendPayload(Sequence), ParseRecvPayloadSequence, CalculateSequencePayloadMax/StartAdr) – two telegram sequences do not work: the RobotTask never finishes the initialization (A-01); the 1st sequence fills the whole telegram (SEQUENCE_MAX_PAYLOAD_SIZE unused, A-02); CalculateSequencePayloadMax(PRIMARY) not halved, footer not subtracted (A-03); header/ACK of the 2nd sequence only sent/evaluated sometimes (SequenceCountSend, A-04); _fragIdx not reset per sequence (A-05); receive order not by Ack (A-06); start values (A-07); NewSEQ[1] never reset and the whole PLC→RC telegram cleared when sequence 1 gets a new Seq; no check Com.TwoSequences vs UseTwoSequences (A-08). Fix: own area per sequence, both headers always sent, lower Ack/Seq first, next Seq = other sequence + 1 (common counter, 254 → 1 like F56), start values 0/1, per-sequence clear, Ack only accepted if = sent Seq, 16#80AB on inconsistent configuration; test against the SDK (spec: 5.6.5.3 "Multiple Sequences", Fig. 5-205…5-208, table 7-2 16#80AB; SDK 04_Network.cpp (area = telegram − cyclic − footer, 1st = area/2))
  • ST-FIX F64: MC_MoveSplineFB, MC_MoveSuperImposedFB: OnUpdateStateFlags – state DONE sets Done := FALSE (copy error) → the FB never signals Done, Execute TRUE without any status. Fix: Done := TRUE (found by the output invariants) (spec: 5.5.10)
  • ST-FIX F65: MC_RobotTaskFB: OnCall, OnExecRun step 1, HandleLifeSign, HandleSeqAck – loss of the initialization always 16#80A2 even if the RC reports the reason in the telegram state (C-01); lifesign timeout of the RC reported as 16#8AAD "connection lost" (C-02); no telegram sequence timeout (C-03). Fix: RI error of the RC (16#A1…16#AD) from the telegram state, 16#80A7 when the RC is ready for (re)initialization again, 16#80A2 otherwise; lifesign 16#80A5; no new Seq number for 4 × LifeSignTimeOut → 16#80A8, not initialized (spec: 6.1.1, 5.6.5.3/5.6.6.2 (4 × LifeSignTimeOut), tables 5-103 and 7-2)
  • ST-FIX F66: MC_RobotTaskFB.HandleInvalidFrames, body – frames with different lifesign in header and footer are counted but processed; the footer is read at the end of the buffer instead of the telegram (C-04). Fix: footer at TelegramLengthRobToPlc − 1, invalid frame not parsed (spec: 5.6.6.2 (header/footer lifesign))
  • ST-FIX F67: MC_RobotTaskFB.AxesGroupToTelegramSequence – remaining space for acyclic data not checked (C-05). Fix: < sequence header + 1 byte → 16#8002 / 16#8003 (spec: 6.1.1 ("less than 1 byte → error"), table 7-2 16#8002/8003)
  • ST-FIX F68: MC_RobotTaskFB.CheckParameterChanged – changed optional cyclic configuration during operation → error 16#8013 (C-06). Fix: warning 16#7003 (takes effect after re-initialization) (spec: 6.1.1: warning; table 7-3 16#7003)
  • ST-FIX F69: CheckParameterValid of the FBs with EmitterID / ListenerID / SequenceFlag – EmitterID −128 / ListenerID < 0 reported as 16#0008; ListenerID not checked against the ProcessingMode (> 0 in trigger modes, 0 otherwise); SequenceFlag not checked against the ProcessingMode (D-01…D-03). Fix: 8627 "EmitterID must be 0" – condition not specified, not used (spec: tables 5-62, 6-496 (and the other ProcessingMode tables), 7-1: 16#8604, 16#8635, 16#8626, 16#8605, 16#8625)
  • ST-FIX F70: CheckParameterValid of 10 Read FBs, MC_GroupJogFB – ProcessingMode / SequenceFlag not allowed → 16#0008; GroupJog Override → 16#8401 (D-04…D-06) (spec: table 7-1: 16#8603, 16#8616, 16#8410)
  • ST-FIX F71: RobotLibraryBaseExecuteFB/EnableFB.OnExecStart – input Priority never checked (D-08). Fix: 1…4 (spec: table 7-1: 16#8610/8611)
  • ST-FIX F72: MC_CallSubprogramFB.CheckParameterValid – acyclic data > 190 bytes not rejected (D-09). Fix: limit 190 bytes (16#8417: the library has no ReturnAcyclicData – not applicable) (spec: table 7-1: 16#8416)
  • ST-FIX F73: MC_ReadActualPositionCyclicFB.OnExecRun – ToolNo/FrameNo −1 ("currently used", 255 in the telegram) never equal to the returned coordinate system → Enabled never set, outputs never updated (D-10). Fix: −1 matches any returned tool/frame (spec: 6.1.6)
  • ST-FIX F74: RobotLibraryBaseFB.OnCall, AxesGroupMessageLogFB.AddMessageLog, AlarmMessage – messages of the command only with the severity of the last RC response → client-side errors (parameter check) never in the message buffer; AcrID/CmdType missing (E-01, E-03). Fix: error/warning/info of the FB with their own severity, AlarmMessage.AcrID/CmdType (filled when the command was created) (spec: 5.5.11, Fig. 5-137, 7.1)
  • ST-FIX F75: enums RobotLibraryErrorIdEnum, RobotLibraryInfoIdEnum – IDs of the spec missing (16#8D52…8D60, 8D89…8D98, 8E22, 16#6C70, 6D54); names with a wrong value (ERR_LIFESIGN_TIMEOUT_0x8005 = 16#8004, ERR_TELEGRAM_SEQ_TIMEOUT_0x80A8_0x80A8) (E-05, C-08). Fix: elements added, alias names with the correct value (spec: tables 7-1, 7-2, 7-4)
  • ST-FIX F76: MC_GroupResetFB.OnExecRun – after DONE the FastStop half byte is set back to 0. The RC counts every change of the half byte as new stopping commands (e.g. 2 -> 0 = 14), its FastStop counter stays > 0 and no motion is executed any more until the next initialization (found with SRCI_PY_HMI: GroupStop, GroupReset, next move hangs; probably also the INTERRUPTED moves of the JAKA MiniCobo). Fix: half byte not reset (only at the initialization, RobotTask) (spec: 5.6.6.2.1)
  • ST-FIX F77: MC_MonitorWorkAreaFB, MC_MoveSuperImposedDynamicFB, MC_ReturnToPrimaryFB .OnExecRun – blocks on RobotLibraryBaseFB (not on the Execute/Enable base) do not check CMDsEnabled → without running RobotTask they send the command into the ACR and stay Busy (found by the TcUnit tests of the PLC library: axes group with data; in Python only an empty axes group was tested, where the parameter check failed by chance). Fix: ERR_COMMANDS_NOT_ENABLED like the Execute/Enable blocks (spec: 5.5.x output status)
  • ST-FIX F78: RobotLibraryBaseEnableFB.OnCall – the RC answered with an error, Enable FALSE starts the error clear (waits up to 5 s for a response); a new rising edge of Enable in this time is consumed while Error is still TRUE → nothing sent, no Busy, no Error (found by the TcUnit test PM-03: the instance is reused). Fix: the new enable clears the old error first (spec: 5.5.x output status)
  • ST-FIX F79: MC_RobotTaskFB.OnExecRun step 1 – the init timeout reports the momentary telegram state; the RobotTask answers an error state with ACK_ERROR / RESET / INITIALIZE, so the error (e.g. 16#A4 SRCI major version) is only visible part of the time → depending on the phase ERR_TIMEOUT_CMD instead of the reason (TcUnit test SDK-RT-007, ~4 ms per robot cycle on the PLC). Fix: last error state of the initialization reported (spec: 5.6.2)
  • ST-FIX F80: MC_SetTriggerMotionFB.CheckParameterValid – TriggerMode_2 = 0 (undefined, the default: only TriggerMode_1 is used) was rejected with 16#0008 (TcUnit test GEN-05). Fix: TriggerMode_2 UNDEFINED allowed (spec: table 6-692)
  • ST-FIX F81: AxesGroupSystemDataFB.UpdateToolData – the copy into the ToolData array of the RobotTask was commented out ({warning 'ToDo: Compiler Fehler'}), so Write/ReadToolData did not update the PLC copy (frames, loads and work areas were stored). Fix: copy like UpdateFrameData, pointer declared as POINTER TO Tool (spec: 6.2.11)
  • ST-FIX F82: MC_ReadActualPositionCyclicFB.OnExecRun – for the extended joint position OutCmd.ReadingCartesianPositionExt was set instead of ReadingJointPositionExt (copy & paste). Fix: own flag (spec: 6.1.6)
  • ST-FIX F83: CheckParameterValid of the 22 blocks with SequenceFlag (check of F69) – the check "sequence mode ⇔ SequenceFlag" also applied to ProcessingMode DEACTIVATE, so an action started in a sequence could not be deactivated with its SequenceFlag (16#8625) and MC_WaitForTriggerFB not at all. Fix: DEACTIVATE excluded from the check (spec: 5.6.4.5)
  • ST-FIX F84: MC_MoveLinearCamFB.CheckParameterValid – TriggerDelay > 255 ms was rejected (16#0008), although it is a UINT [ms]; MC_MoveCircularCamFB allows 65535. Fix: limit 16#FFFF (spec: 6.4.8)
  • ST-FIX F85: MC_ConfigureConveyorFB.CheckParameterValid – ConveyorType was compared with LINEAR_CONVEYOR_TRACKING twice, so CIRCULAR_CONVEYOR_TRACKING was rejected. Fix: second comparison CIRCULAR_CONVEYOR_TRACKING (spec: 6.3.29)
  • ST-FIX F86: MC_ForceControlFB.CheckParameterValid – ConnectionMode was tested against PLC_SENSOR_RC_ALGORITHM twice, so PLC_SENSOR_ALGORITHM was rejected. Fix: second comparison PLC_SENSOR_ALGORITHM (spec: 6.5.24)
  • ST-FIX F87: MC_UserLoginFB.CheckParameterValid – an empty Username was rejected also in the modes without user name. Fix: check only with Mode USERNAME_AND_PASSWORD (spec: 6.1.10)
  • ST-FIX F88: MC_StopSubprogramFB.CheckParameterValid – TargetID (JobID / InstanceID, UINT in the telegram, -1 = all) was limited to 255 and reported ERR_LISTENERID_MUST_BE_POSITIVE. Fix: limit 65534, error ERR_INVALID_PAR_CMD (spec: 6.5.21)
  • ST-FIX F89: MC_MoveSuperImposedFB.CheckParameterValid – ProcessingMode TRIGGER_CONTINUOUS was rejected, although the spec allows it. Fix: allowed (spec: 6.3.30)
  • ST-FIX F90: MC_MeasuringInputFB.OnApplyOutCmd – OutCmd.MeasuringID was set only at DONE, so a running measurement could not be aborted by its ID with MC_AbortMeasuringInputFB. Fix: also set while ACTIVE (spec: 6.4.14)
  • ST-FIX F91: MC_WriteAnalogOutputFB.CheckParameterValid – Index 0 was accepted (spec 1..32, like MC_ReadAnalogInputFB). Fix: lower limit 1 (spec: 6.4.13)
  • ST-FIX F92: MC_UnitMeasurementFB.CheckParameterValid – an invalid MeasuringMode was reported as ERR_PROCESSINGMODE_NOT_ALLOWED. Fix: ERR_INVALID_PAR_CMD (spec: 6.5.37)
  • ST-FIX F93: MC_RobotTaskFB.HandleSync* (7 data sets), step 10 – NO_SYNCHRONIZATION after the start-up returned before the compare: a change of an enabled data set was never detected, InSync and Synchronized stayed TRUE. Fix: compare always, no transfer with NO_SYNCHRONIZATION (spec: 5.6.7.3)
  • ST-FIX F94: MC_RobotTaskFB.HandleSync* (7 data sets), step 3 – start-up conflict with SyncUserInteraction: the RobotTask waited forever, a write / read of the user did not resolve the conflict (the RC copy was never read again). Fix: while waiting for the user the RC data are read again after every sync timeout (5 s) and compared (spec: 5.6.7.3)
  • ST-FIX F95: MC_RobotTaskFB.HandleSync* (7 data sets), step 13 – AUTOMATIC after the start-up: the jump back to step 10 was commented out, later changes were never synchronized. (spec: 5.6.7.3)
  • ST-FIX F96: CheckParameterValid of 26 motion blocks, REAL_TO_PERCENT_INT/UINT – rates < 0 other than -1 rejected (16#8401..8404), although the spec defines every value < 0 % as the default; the conversion sent them as garbage (-2 % → 653.36 %). Fix: every negative rate is the default (16#FFFF) (spec: e.g. 6.3.2, 6.2.14)
  • ST-FIX F97: MC_WriteRobotDefaultDynamicsFB.CheckParameterValid – rates above 655.35 % sent: they do not fit into the UINT of the telegram and wrapped (655.36 % → 0 %). Fix: 16#8401..8404 (rates above 100 % stay allowed, the RC decides) (spec: 5.6.2, 6.2.14)
  • ST-FIX F98: CheckParameterValid of 44 blocks with ToolNo / FrameNo / LoadNo – a number outside -1..254 (e.g. 255) reported as not available on the RC (16#8413 / 16#8415 / ERR_LOADNO_UNAVAILABLE). Fix: range error 16#8412 / 16#8414 / 16#8418 first (spec: table 7-1)
  • ST-FIX F99: MC_ReturnToPrimaryFB.CheckParameterValid – TrajectoryMode 0 (Invalid, the default) accepted and sent as linear movement. Fix: 16#8409 (spec: 6.3.11)
  • ST-FIX F100: ParseResponsePayload of 109 blocks – _response was not cleared before parsing a response: the RC leaves out trailing zero bytes of the payload, so a shortened response kept the values of the previous command; the write blocks copy the response into the user data (UpdateReferenceDynamics ...) - after a write of 0 the PLC value jumped back to the previous value; hidden in Python because every test used new blocks, found by the TcUnit suite SDK-SYNC (RobotTask reused). Fix: SysDepMemSet(_response, 0) after the header (spec: 5.5.5 (missing bytes = 0))
  • ST-FIX F101: MC_RobotTaskFB.HandleSyncLoadData step 0 – load count check compared HighestToolIndex with the load array. Fix: HighestLoadIndex (spec: 5.6.7.5.1)
  • ST-FIX F102: MC_RobotTaskFB.HandleSync{Tool,Frame,Load}Data, HandleSyncWorkArea step 0 – count check ran before the initialization with the HighestXIndex of the previous connection and the configuration of the previous enable (wrong error after a re-enable with other modes). Fix: checked after Initialized (spec: 5.6.7.5.1)
  • ST-FIX F103: MC_RobotTaskFB.OnExecRun step 0, HandleSeqAck, CreateSendPayloadSequence – RobotTask enabled again with one telegram sequence after an enable with two: HandleSeqAck runs before the new configuration is taken and kept SequenceCountSend = 1, CreateSendPayloadSequence wrote the header of a 2nd sequence behind the end of the telegram - on the PLC memory behind the send buffer was overwritten (constants of the test project, all later tests 16#80A3); found by the TcUnit suite SDK-LOOP. Fix: SequenceCountSend from the new configuration when it is taken (spec: 5.6.5.3)

Not changed (documented only)

  • F4 dead code in ParseRecvPayload, F7 GetDword of the status word (correct without byte swap), F8 footer size (conservative), F11 TurnNumber cannot represent "-0", F39 to be reviewed

[1.5.0.0] - 2026-09-19

Changed

  • Release of the implementation for the SRCI V1.5 specification (It's been lying around here way too long)
  • Changed the license from LGPL V3.0 to MIT in order to achieve broader acceptance

[0.0.0.50] - 2025-10-01

Added

  • Added NotifyParameterChanged log message in all CheckParameterChanged methods
  • Added new error ID ERR_MAXIMUM_DISTANCE_EXCEEDED
  • Added new error ID ERR_INVALID_SAFEREFERENCE_POSITION
  • Added new error ID ERR_SAFETY_SENSOR_NOT_TRIGGERED
  • Added new error ID ERR_RESTART_WHILE_ROBOT_MOVING
  • Added new error ID ERR_UNSUPPORTED_COMBINED_JOG
  • Added new error ID ERR_GROUPRESET_PENDING_MESSAGES
  • Added new error ID ERR_EXPORTMODE_NOT_EXIST
  • Added new error ID ERR_EXPORTNAME_NOT_EXIST
  • Added new error ID ERR_EXPORTNAME_ALREADY_EXISTS
  • Added new error ID ERR_DATALOG_NO_MEMORY_LEFT
  • Added new error ID ERR_DATALOG_ERROR_OCCURRED
  • Added new error ID ERR_INTERNAL_UNDEFINED_STEP
  • Added new error ID ERR_PRIORITY_TOO_LOW
  • Added new error ID ERR_PRIORITY_TOO_HIGH
  • Added new error ID ERR_INTERNAL_ERROR_WITHOUT_ID
  • Added new error ID ERR_POSITION_NOT_REACHABLE
  • Added new error ID ERR_CONFIG_MODES_MUST_BE_IDENTICAL
  • Added new error ID ERR_OPTIONAL_PARAM_MAXIMUM_DISTANCE_NOT_SUPPORTED
  • Added new error ID ERR_OPTIONAL_PARAM_CIRCMODE_VALUE_NOT_SUPPORTED
  • Added new error ID ERR_OPTIONAL_PARAM_IX_NOT_SUPPORTED
  • Added new error ID ERR_OPTIONAL_PARAM_IY_NOT_SUPPORTED
  • Added new error ID ERR_OPTIONAL_PARAM_IZ_NOT_SUPPORTED
  • Added new error ID ERR_OPTIONAL_PARAM_RX_NOT_SUPPORTED
  • Added new error ID ERR_OPTIONAL_PARAM_RY_NOT_SUPPORTED
  • Added new error ID ERR_OPTIONAL_PARAM_RZ_NOT_SUPPORTED
  • Added new error ID ERR_OPTIONAL_PARAM_INCREMENTAL_JOG_NOT_SUPPORTED
  • Added new warning ID WARN_INVALID_ROBOT_STATE_MULTIPLE_CMDS_ACTIVE
  • Added new warning ID WARN_PARAM_CHANGE_NOT_POSSIBLE_DEACTIVATE_FIRST_CTX
  • Added new warning ID WARN_PARAM_CHANGE_NOT_POSSIBLE_DEACTIVATE_FIRST
  • Added new warning ID WARN_HOLD_TO_RUN_REQUIRES_MOTION_IN_SEQUENCE
  • Added new warning ID WARN_TRIGGER_EVENT_WITHOUT_ASSOCIATED_ACTION
  • Added new warning ID WARN_TRIGGER_MODE2_NOT_SUPPORTED_FOR_ALL_MOVES
  • Added new warning ID WARN_SAFE_REFERENCING_VELOCITY_REDUCED
  • Added new warning ID WARN_SAFE_REFERENCING_ADDITIONAL_STEPS_REQUIRED
  • Added new Info ID INFO_CONTINUOUS_UPDATE_NOT_POSSIBLE
  • Added new Info ID INFO_CMD_BOUND_TO_INSTANCE_CONTINUOUS_MODE
  • Added new Info ID INFO_CONTINUOUS_UPDATE_NOT_POSSIBLE
  • Added new Info ID INFO_CMD_BOUND_TO_INSTANCE_TRIGGER_MODE
  • Added StatusRobotArm informations to AxesGroup.State

Changed

  • Changed telegram of MC_EnableRobotFB - moved ManualStep to Bit 01 of the same byte as HoldToRun and added a reserve byte at the end.
  • Changed OnApplyOutCmd method of MC_ReadRobotDefaultDynamicsFB, to use PERCENT_UINT_TO_REAL function instead of PERCENT_INT_TO_REAL(UINT_TO_INT(...) function, which returned -0.01 instead of -1.
  • Changed OnApplyOutCmd method of MC_ReadRobotReferenceDynamicsFB, to use PERCENT_UINT_TO_REAL function instead of PERCENT_INT_TO_REAL(UINT_TO_INT(...) function, which returned -0.01 instead of -1.
  • Changed OnApplyOutCmd method of MC_WriteRobotDefaultDynamicsFB, to use PERCENT_UINT_TO_REAL function instead of PERCENT_INT_TO_REAL(UINT_TO_INT(...) function, which returned -0.01 instead of -1.
  • OutCmd.DynamicValues.Timestamp of MC_ReadRobotReferenceDynamicsFB was not updated in OnApplyOutCmd method.
  • OutCmd.ReferenceDynamicValues.Timestamp of MC_WriteRobotReferenceDynamicsFB was not updated in OnApplyOutCmd method.
  • Changed conditions for acknowledge new MsgID in HandleLogMessagesAck method in MC_RobotTaskFB
  • Reset Initialized flag of RobotTaskFB in OnExecRun method in case of error
  • Changed OutCmd.Progress of all motion commands to optional, so that a value of 65535 is interpreted as -1
  • Reset Busy flag of MC_EnableRobotFB in UpdateStateFlags method if target state is reached
  • Changed condition of step 1 in HandleSyncFrameData, to additionally check the Done state
  • Changed condition of step 1 in HandleSyncLoadData, to additionally check the Done state
  • Changed condition of step 1 in HandleSyncRobotDefaultDynamics, to additionally check the Done state
  • Changed condition of step 1 in HandleSyncRobotReferenceDynamics, to additionally check the Done state
  • Changed condition of step 1 in HandleSyncRobotSWLimits, to additionally check the Done state
  • Changed condition of step 1 in HandleSyncToolData, to additionally check the Done state
  • Changed condition of step 1 in HandleSyncWorkArea, to additionally check the Done state
  • Fixed a bug in HandleSyncToolData method of MC_RobotTaskFB , that the SynchronizationModes of SWLimits was used instead of Tool
  • Fixed a bug in ParseRecvPayloadSequence method of MC_RobotTaskFB, that the payload was not correctly added to a command when the payloadpointer was not zero
  • Fixed a bug in GroupJog FB, that the Busy was not reset when the command becomes Active - which triggered a Cancel if the Enable flag was set to FALSE again.
  • Fixed a bug in GroupJog FB, that the response parameter was not logged because the parameter count was not incremented during parsing the response message.
  • Fixed a spelling mistage in some log messages cancled instead of cancelled

[0.0.0.49] - 2025-09-12

Added

  • Added feature : Allowing data packet to be configured individually per robot instance by using ARRAY[*]. #14
  • Added feature : Allowing data sizes for Tool, Load, Frame and WorkAreas to be configured individually per robot instance by using ARRAY[*]. Related to #14
  • Added property HasError which returns TRUE if an error is set.
  • Added property HasWarning which returns TRUE if a warning is set.
  • Added property HasInfo which returns TRUE if an info is set.
  • Added new method SetError that allows setting an internal FB error.
    Includes parameter Overwrite to control whether an existing error should be replaced. All affected code locations have been updated accordingly.
  • Added new method SetWarning that allows setting an internal FB warning.
    Includes parameter Overwrite to control whether an existing warning should be replaced. All affected code locations have been updated accordingly.
  • Added new method SetInfo that allows setting an internal FB info.
    Includes parameter Overwrite to control whether an existing info should be replaced. All affected code locations have been updated accordingly.
  • Added new FB SystemDataFB to AxesGroup providing array sizes and pointers of system data to the corresponding Read/Write FBs.
    This allows to automatically update system data storage for Tool, Load, Frame, WorkAreas, which is a requirement of the SRCI specification.
  • Added error handling for error 'ERR_PROCESSINGMODE_NOT_DEFINED' to all FBs that use the ProcessingModeparameter.

Changed

  • Refactored all command FBs by moving the update of FB StatusFlags into a dedicated method OnUpdateStateFlags to keep to code OnExecRun of cleaner.
  • Refactored all command FBs by moving the update of FB OutCmd into a dedicated method OnApplyOutCmd to keep to code OnExecRun of cleaner.
  • Modified behavior of StatusFlag Busy in all Enable FBs.
    Previously, Busy was reset on the rising edge of Enabled - Now it remains TRUE for the entire duration the FB is enabled.
  • Modified behavior of StatusFlag ParameterAccepted.
    Previously, it was only set to TRUE once the command entered the Active state - Now switches to TRUE when a command is buffered.

Removed

  • Removed library constant ROBOT_IN_DATA_MAX as it is no longer needed due to the use of ARRAY[*]. Related to #14
  • Removed library constant ROBOT_OUT_DATA_MAX as it is no longer needed due to the use of ARRAY[*]. Related to #14

[0.0.0.48] - 2025-08-22

Added

  • Added PLCManufacturedID to UserData and assign value from _parCfg.Plc.Parameter of MC_RobotTaskFB
  • Added PLCOrderID to UserData and assign value from _parCfg.Plc.Parameter of MC_RobotTaskFB
  • Added PLCSerialNumber to UserData and assign value from _parCfg.Plc.Parameter of MC_RobotTaskFB
  • Added PLCFirmwareVersion to UserData and assign value from _parCfg.Plc.Parameter of MC_RobotTaskFB
  • Added PLCInterfaceVersion to UserData and assign value from _parCfg.Plc.Parameter of MC_RobotTaskFB

Changed

  • Corrected a spelling mistake: renamed CurrenArcUsagePercent to CurrentAcrUsagePercent
  • Corrected some spelling mistakes: changed ARC to ACR (A)ctive (C)ommand (R)egister
  • Reset CurrentArcUsageCount in Reset method of ActiveCommandRegisterFB.
  • Reset CurrentArcUsagePercent in Reset method of ActiveCommandRegisterFB.
  • LifeSign counter in HandleLifeSign method of MC_RobotTaskFB is now reset to 0 in case that the Enable input of MC_RobotTaskFB is FALSE.
  • Pre-initialized AxesGroupID of MC_RobotTaskFB with value 0 again instead 1 ( 1 looks like a misstake in der SRCI specification ).
  • In case of TelegramState errors TelegramCtrl.Reset is used instead of TelegramCtrl.ACK_ERROR to acknowledge the error, because with TelegramCtrl.ACK_ERROR the ARC is not reset on the robot side.
  • Fixed a bug that the Initialized Bit of the MC_RobotTaskFB was set to early, because of the command order change in the previous V0.0.0.47 update
  • Fixed a bug that the Busy Bit of the MC_RobotTaskFB was reset to early, because of the command order change in the previous V0.0.0.47 update
  • Harmonized Logging messages for ACR log messages starting with ARC-ID [x] :
  • Changed the Severity of the ACR log messages from Severity.DEBUG to Severity.INFO
  • Check Severity at the begin of all CreateLogMessage FBs to protect unnecessary sub method calls.
  • Assigned InternalLogger interface to ActiveCommandRegisterFB which was previously missing, so that ACR log messages was not displayed in SystemLog.
  • Increased the string length of variable Name from 20 to 80 in RobotLibraryBaseFB ( it is inherited by all other FBs )
  • Skip HandleSync action if no synchronization is configured (neither at startup nor after). (Temporary solution, not final yet)
  • Example Beckhoff : Switched from AdsAndFileLoggerFB to FileLoggerFB and added method HandleLogger in Robot (PRG).
  • Example Beckhoff : Changed LogLevel in RobotTask from LogLevel.DEBUG to LogLevel.INFO
  • Example Codesys : Created a codesys based FileLoggerFB and added method HandleLogger in Robot (PRG).
  • Example Codesys : Changed LogLevel in RobotTask from LogLevel.DEBUG to LogLevel.INFO

[0.0.0.47] - 2025-08-11

Changed

  • Moved InvalidFrames counter from MC_RobotTaskFB to AxesGroup.State.
  • Removed AxesGroupInstances counter from RobotLibraryDefines.
  • Pre-initialized AxesGroupID of MC_RobotTaskFB with value 1.
  • Reset Synchronized flag of MC_RobotTaskFB on LifeSign timeout or TelegramState error.
  • Return TelegramState errors as ErrorID in MC_RobotTaskFB.
  • Handle Byte-Order-Swap in WordToArmConfigShoulder , which was previously missing and led to an incorrectly applied shoulder configuration.
  • Handle Byte-Order-Swap in WordToArmConfigElbow , which was previously missing and led to an incorrectly applied elbow configuration.
  • Handle Byte-Order-Swap in WordToArmConfigWrist , which was previously missing and led to an incorrectly applied wrist configuration.
  • Fixed bug in AddArmConfig method of RobotLibrarySendDataBaseFB that could previously lead to an incorrectly applied arm configuration.
  • Renamed TelegramState enum items to more meaningful names.
  • Modified TELEGRAM_STATE_TO_STRING function according to the changes in the TelegramState enum items.
  • Reset ErrorAddTxt in the Reset method of MC_RobotTaskFB.
  • Changed execution order of commands in the OnExecRun method of MC_RobotTaskFB.
  • Corrected a spelling mistake: renamed ARC_USAGE_WARNING_LIMIT to ACR_USAGE_WARNING_LIMIT.
  • Fixed a wrong log message text in CreateCommandPayloadLog method of MC_ShiftPositionFB.
  • Fixed a wrong log message text in CreateCommandPayloadLog method of MC_MoveDirectAbsoluteFB.

[0.0.0.46] - 2025-08-02

Added

  • Added two missing reserve bytes in GroupJogSendData.
  • Introduced ReadingCartesianPosition, ReadingCartesianPositionExt, ReadingJointPosition, and ReadingJointPositionExt flags to the AxesGroupState structure.
  • Added missing comments to some variables for better code documentation.

Changed

  • Moved the configuration of two sequences from global library parameters to the local ParCfg.Com of RobotTaskFB, enabling instance-specific configurations.
  • Fixed a bug in the split transmission of command payloads where too few bytes were added.
  • Fixed a bug in ReadToolData where ToolNo was transmitted as SINT instead of USINT, causing the tool values of the Flange to always be returned.
  • Fixed a bug in ReadFrameData where the date was parsed as USINT instead of UINT, resulting in incorrect values.
  • Fixed a bug in ReadRobotData where the robot interpreter version was displayed with special characters (e.g., $0). Changed the variable to STRING(5) and added a dot separator between version numbers.
  • Updated RemainingDistance and Progress values of all motion commands during the ACTIVE state, not just upon reaching the DONE state.
  • The RemoveCmd method of ActiveCommandRegisterFB now returns feedback indicating whether the command was successfully removed.
  • Fixed a bug in all FBs inheriting from EnableBaseFB where, in case of cancelation, no telegram with Enable = FALSE was sent if the RemoveCmd method failed because the command was already executing.
  • Fixed a bug in all FBs inheriting from ExecuteBaseFB where, after a reset, the RemoveCmd method was called with UniqueID = 0 due to the reset clearing the ID.
  • Overrode the OnCall method of MC_ReadActualPositionCyclicFB to update the AxesGroup.State flags for reading position data. The base implementation of OnCall is still invoked.
  • Updated the ReadingCartesianPosition, ReadingCartesianPositionExt, ReadingJointPosition, and ReadingJointPositionExt flags in the HandleUserData method of RobotTaskFB.
  • Hid several local variables from the online view using the hide pragma to improve clarity and reduce visual clutter in diagnostics.
  • Removed the CreateUniqueID method from ActiveCommandRegisterFB, as the UniqueID corresponds to the ARC index.
  • Improved logging in ActiveCommandRegisterFB by including the current ARC index and CmdType where previously missing.

Removed

  • Removed several ToDo pragmas, as the associated items were clarified and already correctly implemented (primarily regarding ListenerIDs / EmitterIDs, which are always 0).
  • Removed unused structure AxesGroupAcyclicAcrEntryCmd
  • Removed unused structure AxesGroupAcyclicAcrEntryCmdHeader
  • Removed unused structure AxesGroupAcyclicAcrEntryCmdTrigger
  • Removed unused structure AxesGroupAcyclicAcrEntryRsp
  • Removed unused structure AxesGroupAcyclicAcrEntryRspHeader
  • Removed unused structure AxesGroupAcyclicAcrEntryRspTrigger
  • Removed unused structure AxesGroupParameterCmdEntry

[0.0.0.45] - 2025-07-24

Added

  • Constant HAS_ERROR = -1 to allow checking function return values for -1 in a more readable way.
  • New method CheckAddParameter to determine whether a parameter needs to be sent or can be omitted—along with all following parameters — if it and the remaining values are null.
  • Property IsPayloadRemaining to RobotLibraryResponseDataFB, which returns TRUE if there is remaining data in the payload. This is relevant for parsing incoming payloads that may have been shortened.

Changed

  • Outgoing payload generation was optimized to include only as many parameters as actual values are present in the message. Trailing null values are omitted to save payload size, in accordance with the specification.
  • Outgoing payload logging now excludes trailing parameters with null values that were not transmitted.
  • Incoming payload handling now imports only parameters that have non-null values, assuming the sender already shortened the message accordingly.
  • Incoming payload logging now logs only parameters that actually received a value from the payload.
  • Logging during payload parsing now includes the number of parsed parameters in the initial log message.
  • Logging during payload sending now includes the number of transmitted parameters in the initial log message.
  • OnExecCancel is now called repeatedly until it returns either OK or HAS_ERROR, instead of being called only once. This change applies to both RobotLibraryBaseExecuteFB and RobotLibraryBaseEnableFB.
  • OnExecErrorClear is now called repeatedly until it returns either OK or HAS_ERROR, instead of being called only once. This change applies to both RobotLibraryBaseExecuteFB and RobotLibraryBaseEnableFB.
  • Overridden the OnExecErrorClear method in all RobotLibraryBaseEnableFB derivatives to ensure that an additional telegram with Enable = FALSE is always sent when acknowledging an error. This prevents functions—such as GroupJog—from getting stuck in certain cases.

[0.0.0.44] - 2025-07-01

Added

  • Example project for Beckhoff
  • Example project for Codesys

Changed

  • Build.yml to add the example project to the release

[0.0.0.43] - 2025-05-29

Added

  • function-specific initial value for ExecMode variable in all function FBs within the FB_init method.
  • function-specific initial value for Priority variable in all function FBs within the FB_init method.
  • function-specific initial value for ProcessingMode variable in all function FBs within the FB_init method.
  • function-specific initial value for AbortingMode variable in all function FBs within the FB_init method.
  • function-specific initial value for SequenceFlag variable in all function FBs within the FB_init method.
  • missing Synchronized flag check and combined it with Initialized condition where applicable.

Changed

  • moved declaration of ARC_USAGE_WARNING_LIMIT from Constant GVL to Parameter GVL.
  • moved ProcessingMode variable from ParCmd structure to FB header in MC_ActivateNextCommandFB.
  • Completly revised MC_ReadCallSubprogramCyclic function.
  • Corrected some incorrect error code assignments.
  • Changed base FB type of MC_ActivateConveyorTrackingFB and adjusted implementation accordingly.
  • Changed base FB type of MC_ForceControlFB and adjusted implementation accordingly.
  • Changed base FB type of MC_ForceLimitFB and adjusted implementation accordingly.

Removed

  • duplicate declaration of TOOL_MIN — originally defined in Parameter GVL, but redundantly declared in Constant GVL.
  • duplicate declaration of TOOL_MAX — originally defined in Parameter GVL, but redundantly declared in Constant GVL.
  • duplicate declaration of FRAME_MIN — originally defined in Parameter GVL, but redundantly declared in Constant GVL.
  • duplicate declaration of FRAME_MAX — originally defined in Parameter GVL, but redundantly declared in Constant GVL.
  • duplicate declaration of LOAD_MIN — originally defined in Parameter GVL, but redundantly declared in Constant GVL.
  • duplicate declaration of LOAD_MAX — originally defined in Parameter GVL, but redundantly declared in Constant GVL.
  • duplicate declaration of WORK_AREAS_MIN — originally defined in Parameter GVL, but redundantly declared in Constant GVL.
  • duplicate declaration of WORK_AREAS_MAX — originally defined in Parameter GVL, but redundantly declared in Constant GVL.
  • duplicate declaration of SUB_PROGRAM_DATA_MAX — originally defined in Parameter GVL, but redundantly declared in Constant GVL.
  • obsolete OnExecRun_org method from MC_RobotTaskFB.

[0.0.0.42] - 2025-05-01

Added

  • Functions to compare data objects:
    • IsFrameDataEqual
    • IsToolDataEqual
    • IsLoadDataEqual
    • IsSwLimitsEqual
    • IsWorkAreaEqual
    • IsDefaultDynamicsEqual
    • IsReferenceDynamicsEqual
  • Methods to handle synchronization:
    • HandleSyncFrameData
    • HandleSyncToolData
    • HandleSyncLoadData
    • HandleSyncWorkArea
    • HandleSyncSwLimits
    • HandleSyncDefaultDynamics
    • HandleSyncReferenceDynamics
  • Some missing Error, Warning, and Info events from the specification (still incomplete).

Changed

  • Array definitions updated to use range 0..MAX-1 for:
    • FrameData
    • ToolData
    • LoadData
    • WorkAreas

[0.0.0.41] - 2025-04-13

Added

  • SyncTime Enum.
  • TO_STRING conversion for SyncTime.
  • Preparations for synchronization mechanism in RobotTask (not yet implemented).
  • Distinction between SyncMode values: SYNC_DURING_STARTUP and SYNC_AFTER_STARTUP.

Changed

  • Renamed:
    • RobotTask.ExchangeConfiguration to RobotTask._exchangeConfiguration.
    • RobotTask.ReadRobotData to RobotTask._readRobotData.
    • RobotTask.ReadMessaged to RobotTask._readmessaged.
  • Consolidated AxesGroup.InternalData and AxesGroup.State into AxesGroup.State.
  • Standardized method usage: replaced OnCall with OnExecRun for command execution (OnCall remains in BaseFB).
  • Assigned more meaningful names to SyncReaction items.

Fixed

  • Issue with acknowledgement of LogMessages via ReadMessagesFB.

[0.0.0.40] - 2025-04-03

Added

  • TO_STRING conversion functions for AlarmMessage and AlarmCode.
  • Library parameter MESSAGE_TEXT_LEN for consistent string definitions.
  • Monitoring of ARC usage with log messages when free registers run out.
  • RobotLibraryRecvDataBaseFB and RobotLibrarySendDataBaseFB (without payload definitions).
  • RobotLibraryResponseDataFB and RobotLibraryCommandDataFB (with specific payloads).
  • Initialized flag of RobotTaskFB in AxesGroup.InternalData.
  • Initialization check in all CommandFBs with error raised if RobotTask is uninitialized.
  • Check in all CommandFBs that no command error is pending before execution.

Changed

  • RobotLibraryRecvDataFB and RobotLibrarySendDataFB now extend their respective base FBs and define specific payloads.
  • Replaced:
    • All ResponseData definitions of type RobotLibraryRecvDataFB with RobotLibraryResponseDataFB.
    • All CommandData definitions of type RobotLibrarySendDataFB with RobotLibraryCommandDataFB.
  • Moved:
    • Time conversion functions to a dedicated folder.
    • BaseFBs to a dedicated folder.
    • AxesGroupMessageLogFB to a new folder.
  • AxesGroupMessageLogFB now implements the IMessageLogger interface.
  • Optimized:
    • Execution behavior of all EnableFBs to prevent hangs when disabling.
    • Internal debugging: messages are now pushed to the SystemLog array.
    • Message logging: command-related events now logged, not just messages from ReadMessagesFB.
  • Replaced some general ParCmd error messages with specific messages (per SRCI specification; some still pending).

Removed

  • FSM state machine from BaseFBs.
  • ErrorClear mechanism from RobotTaskFB (now: set Enable to FALSE to acknowledge errors or trigger reset).

[0.0.0.39] - 2025-03-23

Added

  • Constant for PLC library version.
  • Method HandleUserData in RobotTaskFB to update UserData.
  • Enumeration AxisUnit.
  • Structures and conversion functions for:
    • JointAxisUsed and JointAxisUnit
    • ExternalAxisUsed and ExternalAxisUnit
  • ConfigurationData in AxesGroup.InternalData to access ExchangeConfiguration.OutCmd.
  • MessageLevel to RobotTaskParCfgRobParameter and related handling in RobotTaskFB.

Changed

  • ReadRobotDataOutCmd and UserData structures adapted to changes in axis unit/usage definitions.
  • ParameterValid methods of BrakeTestFB and OpenBrakeFB updated accordingly.
  • Payload definition of ARC entries now uses PARAMETER_PAYLOAD_MAX and RESPONSE_PAYLOAD_MAX (set to 255) to reduce memory usage.
  • Fragment definitions in telegram sequence structures now based on FRAGMENT_MAX.

Removed

  • Library parameter TELEGRAM_PAYLOAD_MAX (replaced by ROBOT_IN_DATA_MAX and ROBOT_OUT_DATA_MAX).
  • Library parameter LIFE_SIGN_TIMEOUT (now part of RobotTask.ParCfg).
  • Unused structures MessageHeaderCommand and MessageHeaderResponse.

Fixed

  • ParseRecvPayloadSequence method optimized to handle multiple fragments and prepare support for 2nd sequence (not yet tested).
  • AxesGroupToTelegramSequence adjusted to prepare support for 2nd sequence (not yet tested).

[0.0.0.38] - 2025-03-13

Added

  • Telegram error 173 (not in specification V1.3; discovered during Yaskawa testing).
  • Reset method to RobotTask to reset internal variables on falling edge of the Enable flag.

Changed

  • CheckFunctionSupport method of mandatory commands now always returns TRUE.
  • Assignment of SystemLog and MessageLog moved from OnCall to FB body for access to VAR_IN_OUT.

Fixed

  • MC_ReturnToPrimaryFB and related structures corrected (incorrect in spec V1.3; discovered during Yaskawa testing).
  • Bug in ManageRegister of ActiveCommandRegisterFB that prevented subsequent registers from being checked if a previous register had no valid CommandFB.

Removed

  • STAUBLI_SIMULATOR flag.

Changed

  • Most TO_STRING methods corrected and improved.
  • AddRsp method of ActiveCommandRegisterFB now uses meaningful constants instead of hardcoded indexes.
  • Callback behavior updated: callback moved from ManageRegister to AddRsp to ensure associated CommandFB receives response in the same PLC cycle.
  • LifeSign handling optimized: LifeSign = 0 only used in the first cycle to indicate communication start.
  • Logging messages optimized.

[0.0.0.37] - 2025-03-05

Added

  • System-dependent functions: IsValidReal and IsValidLReal.
  • Read RobotData results to AxesGroup.InternalData.
  • Missing enumerations and corresponding TO_STRING conversion functions.
  • CheckParameterValid method added to all command FBs with command-specific parameter validation.

Changed

  • CheckParameterChanged method modified to execute parameter validation only when the command FB is running.

Fixed

  • Corrections in command-specific structures.

[0.0.0.36] - 2025-02-17

Added

  • Padding bytes in CreateCommandPayload method of MC_GroupJogFB - not specified in SRCI spezification V1.3, but required for correct command execution - (discovered during Stäubli testing)

Fixed

  • Issue with FastStop mechanism: counter is no longer decremented after GroupStop / GroupInterrupt; it can now only be reset using GroupReset.

[0.0.0.35] - 2025-02-08

Added

  • Additional logging for all parameters in the response payload.
  • Method to convert %-INT values to REAL, handling optional values (16#FFFF → -1.0).
  • Method to convert REAL values to %-INT, handling optional values (-1.0 → 16#FFFF).
  • Additional TO_STRING methods for logging enum-based parameters with name and value.
  • Mechanism for internal triggering of parameter updates to the ARC Register (without changing ParCmd).
  • Call to FB-specific CheckParameterValid method within CheckParameterChanged, used as condition for parameter update.

Changed

  • Renamed enumeration items in:
    • RobotLibraryErrorIdEnum
    • RobotLibraryWarningIdEnum
    • RobotLibraryInfoIdEnum — now using more meaningful names.
  • Unified LogLevel and Severity by using LogLevel as alias.

Changed

  • Optimized log texts.

[0.0.0.34] - 2025-02-03

Added

  • Additional logging for all command payload parameters.
  • TO_STRING methods for logging enum-based parameters with clear text and value.
  • Preparation for extended logging of all parameters in response payload (not yet implemented).

Changed

  • UniqueID now corresponds to the ARC index.
  • ARC register size is now based on the smaller value of PLC-ARC size and Robot-ARC size.
  • Simplified command payload creation for ConfigMode using ArmConfigParameterToBytes.

Fixed

  • Implicit conversion warnings.

[0.0.0.33] - 2025-01-19

Added

  • RcSupportedFunctions to AxesGroupInternalData to enable function support checks.
  • CheckFunctionSupported method to all Command FBs: blocks execution if function is unsupported by the RC.
  • CheckParameterValid method to all Command FBs (currently only prepared, not fully implemented).
  • Pre-initialization of RcSupportFunctions bits (ExchangeConfiguration, ReadRobotData, ReadMessages) to TRUE for RobotTask initialization sequence.

Changed

  • Execution performance of Command FBs improved: telegram is now written to fieldbus within the same PLC cycle as FB activation (requires Command FBs before RobotTaskFB).
  • ReadActualPositionCyclic command fundamentally revised.
  • Optional parameters JerkRate and DecelerationRate handled in:
    • BasicMove commands
    • ReadDefaultDynamics / WriteDefaultDynamics
  • Optional parameters JerkReference and DecelerationReference handled in:
    • ReadReferenceDynamics / WriteReferenceDynamics
  • Datatype of RaSequenceState in RaStatusWord changed to enum instead of single bits.
  • Reorganized conversion functions into separate folders.
  • All TO_STRING functions converted to uppercase.

Fixed

  • Spelling mistakes.

[0.0.0.32] - 2025-01-12

Changed

  • Internal timestamp format updated to support millisecond resolution for improved debugging.
  • Logging messages enhanced with more detailed information.

Fixed

  • Bug in ActiveCommandRegister / ExecutionOrderList affecting CmdID in FragmentHeader, which could cause sporadic decoding errors on the robot side.

Added

  • Preparation of FragmentCounters for the second telegram sequence.

[0.0.0.31] - 2025-01-08

Added

  • Legal notice to README.md.
  • New functions to convert Siemens formats to TwinCAT/3S formats:
    • IEC_DATE_TO_DATE
    • IEC_TIME_TO_TIME
    • IEC_TIMESTAMP_TO_DT
  • ReadMessagesFB is now integrated into RobotTaskFB and starts during interface initialization.
  • RobotTaskFB now clears a potentially pending interface error when starting.
  • Missing PRIVATE keywords added to several private methods.

Changed

  • Software status updated in README.md.
  • Renamed function blocks:
    • SendData → RobotLibrarySendDataFB
    • RecvData → RobotLibraryRecvDataFB
  • Initial values updated in the parameter list for:
    • TOOL_MAX, FRAME_MAX, LAOD_MAX, WORK_AREAS_MAX, MESSAGE_LOG_MAX
  • XNULL (DWORD) replaced by NULL_POINTER (POINTER TO BYTE) (due to CODESYS compiler issue).
  • AxesGroupMessageLog changed from a struct to a function block with methods for adding, deleting, and sorting messages.
  • ExecutionAbort code moved from instances into the associated base FBs.
  • Array sizes of SystemLog and MessageLog adjusted.
  • Base function block of MC_ReadMessagesFB changed from ExecuteBaseFB to EnableBaseFB to match specification.

[0.0.0.30] - 2025-01-02

Added

  • Missing assignment of AxesGroup.CyclicOptional.RobToPlc.SubProgramData.

Changed

  • Behavior of applying RobotTask.ParCfg.
  • RobotTask.OnCall now cyclically updates:
    • AxesGroup.Cyclic.PlcToRob.ClientDate
    • AxesGroup.Cyclic.PlcToRob.ClientTime
  • Separate telegram footer structures now used for RobToPlc and PlcToRob (due to structural differences).
  • Parsing of Telegram.RobToPlc.Footer.LifeSign simplified in RobotTask.ParseRecvPayloadFooter.

[0.0.0.29] - 2024-12-24

Added

  • Library category.

Changed

  • LifeSign address in telegram is now variable (was previously hardcoded to byte [255]).

Fixed

  • Incorrect assignment of ArmConfig in CartesianPosition.

[0.0.0.28] - 2024-12-21

Added

  • Intermediate abstraction layer to generalize system-specific functions.
  • Common interfaces for system-specific operations.
  • Implementations of these interfaces for CODESYS and TwinCAT targets.

Changed

  • Improved modularity and portability by decoupling system-specific implementations.

[0.0.0.27] - 2024-12-16

Added

  • Plain text versions of source-code files (*.ST) to improve GitHub diff tracking and code reviews.

Changed

  • Source code is now also available in plain text format alongside the existing Library and PLCopen XML files.

[V0.0.0.26] - 2024-12-08

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.25] - 2024-12-01

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.24] - 2024-11-29

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.23] - 2024-11-24

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.22] - 2024-11-20

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.21] - 2024-11-10

Changed

  • No detailed change information provided – early development phase.
  • Changed License information

[V0.0.0.21] - 2024-11-10

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.21] - 2024-11-10

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.20] - 2024-09-08

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.19] - 2024-09-02

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.18] - 2024-08-11

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.17] - 2024-08-10

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.16] - 2024-08-08

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.15] - 2024-08-03

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.15] - 2024-08-03

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.14] - 2024-08-01

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.13] - 2024-07-29

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.12] - 2024-07-03

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.11] - 2024-06-30

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.10] - 2024-06-23

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.9] - 2024-06-22

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.8] - 2024-06-20

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.7] - 2024-06-17

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.6] - 2024-06-16

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.5] - 2024-06-11

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.4] - 2024-06-09

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.3] - 2024-06-05

Changed

  • No detailed change information provided – early development phase.

[V0.0.0.2] - 2024-06-04

Changed

  • No detailed change information provided – early development phase.