Skip to content

Releases

Release v1.5.2

Choose a tag to compare

@github-actions github-actions released this 15 Nov 14:44

Generated from the PLC library 1.5.7.0. First release in this repository (the earlier releases were
published from the development repository).

Added

  • OPC UA transport for robot controllers that publish their PROFINET I/O byte by byte (e.g. Staubli
    CS9): OpcUaTransport also takes a list of NodeIds for out_node / in_node, one node per byte;
    all nodes of a direction go in one Write and one Read request, write_changed_only writes only the
    changed bytes, consistency_byte writes a check byte invalid first and valid last.
  • Configuration files (TOML) for the OPC UA transport: OpcUaTransport.from_config / from_profile,
    load_opcua_config, opcua_profiles (endpoint, user, node layout, recommended cycle time and
    LifeSign timeout). Shipped: srci_bridge_twincat, staubli_cs9.
  • OpcUaRcSimulator(per_byte=True) and config().

Changed

  • SafeReferencing sends a reserved byte after ToolNo, as robot controllers based on the SRCI SDK
    expect it; MaximumDistance starts at byte 14. The telegram table of the specification (6-838) has
    no reserved byte - the deviation is reported to PI.
  • ReadSafeReferencePosition reads the external axes E1..E6 directly after J6, as the robot controller
    sends them (before they were read 20 bytes too late). ReadSafeReferencePositionRecvData has no
    field CartesianPositionExt any more.