Release v1.5.2
Generated from the PLC library 1.5.7.0. First release in this repository (the earlier releases were
published from the development repository).
Added
- OPC UA transport for robot controllers that publish their PROFINET I/O byte by byte (e.g. Staubli
CS9):OpcUaTransportalso takes a list of NodeIds forout_node/in_node, one node per byte;
all nodes of a direction go in one Write and one Read request,write_changed_onlywrites only the
changed bytes,consistency_bytewrites a check byte invalid first and valid last. - Configuration files (TOML) for the OPC UA transport:
OpcUaTransport.from_config/from_profile,
load_opcua_config,opcua_profiles(endpoint, user, node layout, recommended cycle time and
LifeSign timeout). Shipped:srci_bridge_twincat,staubli_cs9. OpcUaRcSimulator(per_byte=True)andconfig().
Changed
- SafeReferencing sends a reserved byte after
ToolNo, as robot controllers based on the SRCI SDK
expect it;MaximumDistancestarts at byte 14. The telegram table of the specification (6-838) has
no reserved byte - the deviation is reported to PI. - ReadSafeReferencePosition reads the external axes E1..E6 directly after J6, as the robot controller
sends them (before they were read 20 bytes too late).ReadSafeReferencePositionRecvDatahas no
fieldCartesianPositionExtany more.