You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
This commit was created on GitHub.com and signed with GitHub’s verified signature.
A warning when one Broadcastify system ID covers several sites. Broadcastify Calls records
every call a system ID uploads as coming from the site it's registered to, so the other sites'
calls were labeled as the wrong site. The plugin now says so (uploads go on as they are), in the
log and as a notice on its card, under its status, until recording starts again (Trunk Recorder
Pro after 0.5.0; 0.5.0 and earlier show it in the log only). It's checked at
start (a system's ID with several sites that have none of their own, one ID on several site rows,
one ID on several systems) and from the health reports, for sites that appear while recording.
Each site gets its own ID in its row in the plugin's settings; more can be applied for at
broadcastify.com/apply/calls.
One health report per system ID. Sites of a system that name the same Broadcastify system ID
(with no ID for the whole system, or each set to one) sent a report each, every interval, all as
that ID; Broadcastify takes one per ID each interval and turned the rest away (429). They're
now one report of all those sites. Two recorder systems on one ID are reported for the first.
One ID given two API keys is said (reports use the first).
No report with no time in it. A plugin (re)started while the recorder was already recording (its
settings saved, say) sent a first report whose window began where it ended, which Broadcastify
turned down (400 window.end must be after window.start). It now waits for the next totals.
Built with trunk-recorder-plugin 0.16.0 (its notices).