1.2.0b5

Pre-release
Pre-release

Choose a tag to compare

@Varitras Varitras released this 27 Sep 11:35
· 367 commits to 7b4ca185ae37ccfcdeee5b2f9e19df8c7097cfea since this release

A beta on 1.2.0b4 that makes the throttle reason report a limit that actually holds the output, renames several sensors after what they measure, and makes discovery confirm a moved inverter before following it. No migration; unique ids and entity ids do not change. Automations that wait for the throttle states export_limit or active_power_control need the new states (see below).

Throttle reason

The sensor used the Modbus signals, which only say a limit is switched on: an AC limit left at 100 % read as throttling, and an export limit holding the output read as "not throttled" (#26). It now follows the inverter's component endpoint, which reports whether a limit holds the output, and it follows the web poll too.

Raw state 1.2.0b4 (EN) 1.2.0b4 (DE) 1.2.0b5 (EN) 1.2.0b5 (DE) Reported when …
none Not throttled Keine Drosselung Not throttled Keine Drosselung no limit holds the output
inverter_state Inverter reports throttling Wechselrichter meldet Drosselung Inverter reports throttling Wechselrichter meldet Drosselung the inverter reports throttled itself (a GEN24 did not)
ac_limit – – AC limit AC-Leistungsbegrenzung a percentage limit is reached, e.g. the AC limit
feed_in_limit – – Export limit Einspeisebegrenzung a limit in watts is reached, measured with the export limit
several Several reasons Mehrere Gründe Several reasons Mehrere Gründe more than one reason at once
export_limit Export limit Einspeisebegrenzung AC limit AC-Leistungsbegrenzung never – kept for older history only
active_power_control Active power control Wirkleistungsvorgabe Active power control Wirkleistungsvorgabe never – kept for older history only
unknown – – – – no reason found while a source is missing

In 1.2.0b4, export_limit was labelled "Export limit" / "Einspeisebegrenzung" although it meant the AC limit. Older history entries with export_limit now carry the correct label "AC limit".

Renamed sensors

Sensor 1.2.0b4 (EN) 1.2.0b5 (EN) 1.2.0b4 (DE) 1.2.0b5 (DE)
Production limit Production limit Output power limit Aktuelle Produktionsgrenze Zulässige Ausgangsleistung
Production limit reached Production limit reached Output limited Leistungsgrenze erreicht Ausgangsleistung begrenzt
Max charging power Max charging power Charge/discharge reference power Lade-Referenzwert Lade-/Entlade-Referenzleistung
AC power AC power – AC-Leistung AC-Wirkleistung
Power / L1–L3 (smart meter) Power – Leistung Wirkleistung
Exported / Imported, total and L1–L3 (smart meter) Exported / Imported – Exportiert / Importiert Eingespeist / Bezogen
State of health State of health – Gesundheit (SoH) Gesundheitszustand (SoH)
Battery max charge / discharge power (DC-DC) unchanged – Batterie max. Lade-/Entladeleistung Speicher max. Lade-/Entladeleistung
Feed-in point frequency / voltage unchanged – Einspeisepunkt Frequenz / Spannung Frequenz / Spannung Einspeisepunkt
AC limit enable (select) AC limit enable – AC-Begrenzung aktivieren AC-Leistungsbegrenzung aktivieren

Only the displayed names change; entity ids, history and automations stay. A name you gave an entity yourself stays too.

Security

  • Discovery follows an announced new address only when a Modbus read finds the inverter's serial number there and no longer at the entry's address; an announced address that does not answer yet is read again for a few minutes. The serial number an announcement carries is no secret, so anyone able to send mDNS could turn an entry, and its Web API login, to another host.

Changed

  • Throttle control is disabled by default for new entries: it reads the same flag as AC limit enabled. Entries that have it keep it.
  • A counter reading the total guard ignores and a Modbus outage the integration bridges after a web write are logged at debug level, not as warnings. A counter jump the guard adopts is still a warning.
  • The price automation example in the README compares the price on every change, at start, and after a reload of the automations or the integration.

Fixed

  • The sensors from the inverter's component endpoints show as many digits as their unit is worth (fans and power without decimals, temperatures and voltages with one, frequency with two) instead of the raw float32 value (#27). Only the display changes; the stored state keeps its value.