1.2.0b6
Pre-releaseA beta on 1.2.0b5 that brings the inverter's own events into Home Assistant, reads the extra modules, fans and temperatures a larger inverter reports, names the module sensors as the inverter's web interface does, and asks before the setup switches the inverter's SunSpec model type. No migration; unique ids and entity ids do not change.
Inverter events
The inverter's web interface lists every event with its code, its time and a text; Modbus reports events only as severity bits. The integration now reads that list without a login:
| Entity | Type | What it shows |
|---|---|---|
| Active event / Aktives Ereignis | sensor, diagnostic | The text of the leading active event in Home Assistant's language (an error before a warning before an info, the newest among equals), OK while none is active. Code, severity, level, time and the other active events as attributes. |
| Active events / Aktive Ereignisse | sensor, diagnostic | How many events are active. |
| Inverter event / Wechselrichter-Ereignis | event | Fires once for every new entry of the inverter's event log, with the severity as its event type (error, warning, info, or unclassified). It catches entries that last no time at all, such as a short battery fault. |
The README has a notification example with the event.received trigger.
Renamed sensors
| Sensor | 1.2.0b5 (EN) | 1.2.0b6 (EN) | 1.2.0b5 (DE) | 1.2.0b6 (DE) |
|---|---|---|---|---|
| Inverter temperature | Temperature | Internal temperature | Temperatur | Innentemperatur |
| Module temperature 1 | Power module 1 temperature | AC module 1 temperature | Temperatur Leistungsmodul 1 | Temperatur AC-Modul 1 |
| Module temperature 2 | Power module 2 temperature | AC module 2 temperature | Temperatur Leistungsmodul 2 | Temperatur AC-Modul 2 |
| Module temperature 3 | Power module 3 temperature | DC module temperature (3) | Temperatur Leistungsmodul 3 | Temperatur DC-Modul (3) |
| Module temperature 4 | Power module 4 temperature | DC or battery module temperature | Temperatur Leistungsmodul 4 | Temperatur DC- oder Batteriemodul |
| Battery power limit | Current power limit | Current charge limit | Aktuelle Leistungsgrenze | Aktuelle Ladegrenze |
The module names are the ones the inverter's own web interface uses. The battery's power limit fell to 0 W near a full battery while the discharge limit stayed, so it is the charge counterpart of Current discharge limit. Only the displayed names change; entity ids, history and automations stay. A name you gave an entity yourself stays too.
New sensors
| Sensor (EN) | Sensor (DE) | Note |
|---|---|---|
| AC module 3–6 temperature | Temperatur AC-Modul 3–6 | only where the inverter reports them (a Verto) |
| DC module temperature (9), (10) | Temperatur DC-Modul (9), (10) | only where reported |
| Fan 3, Fan 4, Fan 5 | Lüfter 3, Lüfter 4, Lüfter 5 | only where reported |
| Ambient temperature 2 | Umgebungstemperatur 2 | only where reported |
| Surplus power available | Überschuss verfügbar | disabled by default; an undocumented flag, seen set while an export limit curtailed PV |
Added
tools/inverter_dump.bat(Windows): saves everything the inverter's web interface and its SunSpec registers read out into one JSON file, with serial numbers, addresses and names redacted by default. Attached to an issue, it helps to support a device that is not verified yet.
Fixed
- The setup switched the inverter's SunSpec model type from
floattoint + SFwithout asking; an external device reading the float models may no longer work after that. Setup, reconfigure, reauthentication and options now ask first while the inverter's Modbus is on; declining leaves the inverter as it is. - Two entries set up at the same time on a fresh installation kept only one Web API token; the other asked for its password again after a reload.
- While the MPPT block did not answer, a negative household load during battery charging showed as 0 W; it is unknown now.
Documentation