Repository navigation
First stable release of 1.3. It contains everything from 1.3.0b1; see CHANGELOG.md for the full history. No new entry migration; unique ids and entity ids do not change. The documentation now lives in the wiki.
Before you upgrade from 1.2.x
- Storage controls refuse more, with a reason. A rate is checked against the inverter's live registers before it is written. A 0 W limit that would block both directions, a limit or grid power after a schedule or another controller changed the storage mode, and a grid power beyond a combined limit another controller left in place are refused with a message instead of a bare Modbus error. Select the storage mode again when asked to.
- Charge from Grid without a web login is an error while the entry waits for a new login; the storage mode is still set.
Control mode: the inverter's active controls sensor (StActCtl) is no longer namedCore storage control mode; its entity id stays.- Modbus IP restriction: the choice that allows this Home Assistant adds its address to the hosts already allowed while the inverter's restriction is on. While it is off, Home Assistant becomes the only allowed host; add any other device that controls the inverter over Modbus in the inverter's web interface. The option text now says so.
New
- The wiki documents every entity with its English and German name, source and range, the battery and inverter controls, the inverter's events, how data updates, examples, troubleshooting and migration. The README keeps the overview, installation, setup and removal.
- A firmware update is picked up on its own: once the inverter answers again after an outage, the integration reads the version of the inverter and its meters again and reloads the entry if it changed. The device page shows the new firmware, and the Solar API repair follows it, without a restart.
- A removed meter or battery can be deleted on its device page. The integration still deletes none on its own.
Fixed
- Enabling Modbus TCP on an inverter whose Modbus server served RTU alone switched it to TCP alone and cut off the device reading it over RS485. RTU now stays served alongside TCP.
- A second storage mode change before the next poll could pass through a rate window the inverter refuses, for example Charge from Grid followed quickly by Block Charging; the inverter stayed in the old mode (upstream callifo#126).
- Updating from callifo 0.3.0 or older lost one of two entities that shared a unique id. Updating from callifo also keeps dark MPPT strings' sensors, a title you gave the entry and, from callifo 0.3.2, the role you chose.
- A new password entered in Configure with every other setting unchanged did not reach the running entry.
- A burst of values for one web number reached the inverter as every single value instead of the first and the last.
- On an inverter whose SunSpec map ends in a refused read, a link that stopped answering was never recognised as down.
The complete list is in CHANGELOG.md under 1.3.0 and 1.3.0b1.