1.4.0b1

Pre-release
Pre-release

Choose a tag to compare

@Varitras Varitras released this 31 Oct 11:38
· 105 commits to main since this release

A beta on 1.3.0: an optional fast read of the grid meter's power for battery controls that follow feed-in and draw, the export soft limit on inverter firmware 1.42, and safer handling of unusual meter and MPPT answers. No new entry migration; unique ids and entity ids do not change.

Worth knowing before you update

  • Grid meter power interval (Configure, off by default): set 1 to 60 seconds, shorter than the update interval, and the primary meter's Power sensor is read on its own at that pace. Everything else stays on the update interval.
  • Export soft limit on firmware 1.42 reads and sets again; it still needs the technician role.
  • A rejected web setting now names the fields the inverter refused, after "Writing to the inverter failed:".

Added

  • An optional interval for the grid meter's power, from 1 to 60 seconds and shorter than the update interval: the primary meter's Power sensor is then read on its own, so a battery control that follows feed-in and draw sees a change within that time. Everything else stays on the update interval. Off by default; set it under Configure.

Fixed

  • An invalid reported meter address could stop entry setup. Only Modbus units 1-247 are now kept; leaving out a unit makes the meter list unconfirmed, so no entity is removed because of it.
  • A smart meter the inverter's web interface listed without a usable address was left out as if it were gone, so a reload could remove the entities of a meter that still exists. Such an answer now leaves the meter list unconfirmed.
  • An MPPT model whose module count disagrees with its length, or reports none, read the following model as a module or dropped all modules, which could move the battery's charge and discharge paths. The module layout now follows the model length; a disagreeing count marks the MPPT read as failed until it fits again.
  • On inverter firmware 1.42, Export soft limit read unknown and setting it failed with 400 Bad Request (upstream callifo#154): that firmware keeps the limit's watts in another place of its export limit settings. Both are now read and written where the firmware keeps them; older firmware is unchanged.
  • A setting the inverter's web interface rejected with an error status, such as Export soft limit answered with 400 Bad Request (upstream callifo#154), failed with the status alone. The error now names the fields the inverter reports as refused.