Repository navigation
DecayCore v1.4.0 — FIR Room Correction and Acoustic Measurement
v1.4.0
Decay before and after correction
New Decay / RT60 and Bass decay views compare measured and predicted decay
for each channel. The Timing view adds an impulse envelope in dB, and reports
include playback headroom recommendations. Decay estimates describe ringing,
not overall sound quality.
Safer correction
Correction fades smoothly at measurement boundaries, and decay correction
respects its frequency limit. Phase correction avoids correcting the same
bass resonance twice. Pre-ringing protection now works, with a default limit
of -25 dB instead of -35 dB.
For left/right correction without Bass Integration, filters that lengthen bass
decay trigger a check of lighter phase correction. Reports explain any remaining
problems or why the original correction was kept when all checks failed.
Separate filters for two subwoofers
Bass Integration supports individual delay, level and polarity for two subs,
with separate results views and a four-output CamillaDSP export. Both sub
measurements must share a timing reference. Bypass playback preserves
crossovers, subwoofer protection and bass alignment.
More reliable Automatic mode
Adaptive targets stay within 1 dB of their base curve. Measured room decay and
distortion discourage extra boost, and measurement gaps no longer influence
adaptation. Search starts consistently on Windows and Linux. Earlier results
are rebuilt and may differ slightly.
Less waiting
Minimum-phase calculation is faster on Windows and Linux; other filter types
are faster on Windows. Bass decay checks skip unnecessary recalculations.
Progress now tracks all four filters through export and shows accurate search
trial counts.
Clearer setup
Basic is now Setup. Settings managed by Automatic mode sit in expandable
sections, zero values are preserved, and unreadable measurements prevent runs.
Room dimensions stay correct when switching units.