You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Structural Search: every run takes a seed, shown in its history, so a run can be replayed.
Gradual Evolution: Deep search keeps a run searching until you press Stop.
Design Editor: a thickness cell steps up and down with arrows that appear on hover or with the mouse wheel over it, and every open window follows as the value moves.
Changed
Roughness Scattering: each interface takes a short-range or long-range roughness, modelled as a transition layer, so a high reflector loses little inside its band and transmitted light is no longer overstated as lost.
Optimization windows: band averages and spectral targets sample as finely as the coating's fringes need, so a thick design's merit is the band's true value and thin designs optimize faster.
Cone angle: refinement and needle synthesis are many times faster on many-layer designs, enough angles are chosen automatically for narrowband filters, and rays past grazing are left out with a warning in the Design Editor.
Design Cleaner and Needle Manual refine with the Refinement window's default method, no longer freeze on large designs, and can be stopped.
Gradual Evolution: Max layers limits the design instead of ending the run. At the limit it frees the layer that costs least and keeps looking, and a run goes on until its GE cycles are used or nothing is left to try.
Integral Values: a row whose band the spectrum does not cover reads n/a with the spectrum's range, the solar rows cover 300-2500 nm, and Tvis and Rvis count narrow notches at their true width.
Structural Optimizer: Min thickness follows the merit function's MNT row, as in Gradual Evolution, and a note under it shows when the two differ.
Variator: thickness sliders run from zero to double the layer; the preview's Targets button matches Optical Evaluation, and the plot has no legend or design line under it.
Monte-Carlo: a run can be replayed from its seed, the spec yield shows the range it can move by chance, and keep n·d holds at the design reference wavelength so the plot range no longer changes the trials; the report's Monte-Carlo block shows the run's own settings.
Fixed
Refinement: no hidden maximum layer thickness (add an MXT row for an upper limit); Damped Least Squares, Newton and Newton-CG no longer stall with layers at the minimum thickness, and Damped Least Squares converges much faster on TGT, RGT and AGT targets and stops once the merit stops falling.
Needle and Gradual Evolution: layers stuck at the minimum thickness are removed when the design is better without them, the merit shown for each step matches the design, insertions are ranked correctly with TANPSI or TOD rows, and Gradual Evolution no longer stops at once on its GE-step limit after a finished run or a Reset, no longer repeats a forced step that the refining after it took back, and no longer fills its history with Needle rows that add no layer. They and Structural Search start the next Run from the design as edited while the window was closed, and show their status and stop messages in the interface language.
Calculations are correct at grazing incidence, exactly at a critical angle, and through layers no light gets through, such as thick metal or an air gap past the critical angle, where optical density no longer stops near 43 and the E-field decays instead of staying flat. Absorptance under an absorbing incident medium is what the coating absorbs, and optimization and Psi/Delta fits get correct gradients through such layers and deep absorbing stacks.
Structural Optimizer no longer stays on its starting design for a whole run, also from a single layer at a high Min thickness; T₀ now defaults to 0.3, Max added to 500 nm and the smart starting design to off.
Systematic Deviations: the global Δn and Δk shift only the coating layers, not the incident medium, substrate or exit medium.
Color Evaluation and the report's colour block count a narrow notch or passband at its true width.
Mono and Broadband Monitoring Simulators: a noiseless run builds the design on target; Mono no longer cuts layers thicker than a quarter wave far too thin and its time cuts carry the rate error; the Broadband thickness fit no longer settles in the wrong fringe, its monitor no longer knows the true thicknesses, and the rate varies inside a layer.
Unsaved work: a design saved from another copy of TFStudio opens as saved, with the older unsaved version one Ctrl+Z back; keeping unsaved work no longer slows editing on large projects.
Variator: switching to another window and back keeps the sliders where they were, and Ctrl+Z takes back what they changed instead of being written over.
Material Editor: the step where a fit hands over to the table is reported and drawn; materials with an unknown formula or an empty table show as unavailable instead of n = 1.5, and AGF glasses with an unknown formula or OptiLayer files with no n values are named and left out.